Metal organic framework/clay composite for micro-dispersive solid-phase extraction of sulfonamides and penicillins in milk, and synthetic urine solution coupling with HPLC/DAD detection

被引:12
|
作者
Aldoori, Mahmood Saad [1 ]
Merdivan, Melek [2 ]
Tagac, Aylin Altinisik [2 ,3 ]
机构
[1] Dokuz Eylul Univ, Grad Sch Nat & Appl Sci, Tinaztepe Campus, TR-35160 Izmir, Turkiye
[2] Dokuz Eylul Univ, Chem Dept, Tinaztepe Campus, TR-35390 Izmir, Turkiye
[3] Dokuz Eylul Univ, Ctr Fabricat & Applicat Elect Mat, TR-35390 Izmir, Turkiye
关键词
MMT; MOF; mu-dSPE; Antibiotics; HPLC; PERFORMANCE LIQUID-CHROMATOGRAPHY; ANTIBIOTIC-RESIDUES; WATER; SORBENT; MICROEXTRACTION; SAMPLES; MONTMORILLONITE; ADSORPTION; AMPICILLIN; POLYMER;
D O I
10.1016/j.microc.2022.108165
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, composite as a copper-containing metal-organic framework with montmorillonite (MMT) clay was synthesized and applied as an adsorbent for micro-dispersive solid-phase extraction (mu-dSPE) of sulfonamides (SAs) and penicillins (PENs). The synthesized composites including different content of MMT were characterized by Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, Brunauer-Emmett-Teller surface area, and thermogravimetric analysis. The determination of antibiotics was performed by high-performance liquid chromatography/diode array detection (HPLC/DAD) using C18 column as stationary phase, 0.1 % trifluoroacetic acid in water, and acetonitrile as mobile phase in gradient mode and detection at 270 nm for SAs and 230 nm for PENs. The as-synthesized composites were examined for their adsorption ability towards target antibiotics. The optimized parameter conditions were 10 mg of adsorbent, 5 mL of sample solution at pH 4, 10 min stirring by vortex, 1 mL of acetonitrile:methanol (1:1) as eluent solvent, and 5 min as elution time. Under optimized conditions, the proposed method presented good linearity from 0.5 to 400 mu g/L for SAs and from 1 to 400 mu g/L for PENs with coefficients of determination (r(2)) >= 0.9947, low limit of detections from 0.10 to 0.15 mu g/L for SAs and 0.30 to 1.50 mu g/L for PENs, acceptable repeatabilities less than 3.26 % for both groups and good recoveries from 82.3 % to 116.4 % with relative standard deviations less than 3.9 % for both groups in the spiked milk samples and synthetic urine solution. The developed mu-dSPE method following HPLC/DAD has been successfully applied to the determination of SAs and PENs milk samples and synthetic urine solutions.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Magnetic Metal-Organic Framework/Graphene Oxide-Based Solid-Phase Extraction Combined with Spectrofluorimetry for the Determination of Enrofloxacin in Milk Sample
    Li, Zhaoqian
    Qi, Mengyu
    Tu, Chunyan
    Wang, Weiping
    Chen, Jianrong
    Wang, Ai-Jun
    FOOD ANALYTICAL METHODS, 2017, 10 (12) : 4094 - 4103
  • [22] Effective determination of trace residues of glibenclamide in urine samples using dispersive micro solid-phase extraction and its final detection by chromatographic analysis
    Eilami, Owrang
    Asfaram, Arash
    Ghaedi, Mehrorang
    Goudarzi, Alireza
    ANALYTICAL METHODS, 2019, 11 (05) : 627 - 634
  • [23] Synthesis of magnetic metal organic framework/covalent organic framework hybrid materials as adsorbents for magnetic solid-phase extraction of four endocrine-disrupting chemicals from milk samples
    Yue, Bing
    Liu, Jianghua
    Li, Guoliang
    Wu, Yongning
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (23)
  • [24] Metal organic frameworks (MOFs) for magnetic solid-phase extraction of pyrazole/pyrrole pesticides in environmental water samples followed by HPLC-DAD determination
    Ma, Jiping
    Yao, Zhidan
    Hou, Liwei
    Lu, Wenhui
    Yang, Qipeng
    Li, Jinhua
    Chen, Lingxin
    TALANTA, 2016, 161 : 686 - 692
  • [25] Fe3O4/reduced graphene oxide-carbon nanotubes composite for the magnetic solid-phase extraction and HPLC determination of sulfonamides in milk
    Feng, Yingying
    Hu, Xiaopeng
    Zhao, Faqiong
    Zeng, Baizhao
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (05) : 1058 - 1066
  • [26] Development and application of metal-organic framework@GA based on solid-phase extraction coupling with UPLC-MS/MS for the determination of five NSAIDs in water
    Zhou, Yiyuan
    Xu, Jiabi
    Lu, Nan
    Wu, Xinyu
    Zhang, Yu
    Hou, Xiaohong
    TALANTA, 2021, 225
  • [27] A Zr(IV)-based porphyrinic metal-organic framework as a solid-phase sorbent for extraction of sulfonamides prior to their quantitation by LC-MS
    Deng, Ze-Hui
    Xu, Gui-Ju
    Wang, Xiao-Li
    Wang, Xia
    Wang, Ming-Lin
    Lin, Jin-Ming
    Zhao, Ru-Song
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [28] Magnetic molecularly imprinted polymer nanoparticles for dispersive micro solid-phase extraction and determination of buprenorphine in human urine samples by HPLC-FL
    Biuck Habibi
    Shiva Rostamkhani
    Mehrdad Hamidi
    Journal of the Iranian Chemical Society, 2018, 15 : 1569 - 1580
  • [29] A hybrid material prepared by controlled growth of a covalent organic framework on amino-modified MIL-68 for pipette tip solid-phase extraction of sulfonamides prior to their determination by HPLC
    Chen, Zhipeng
    Yu, Chen
    Xi, Jiangbo
    Tang, Sheng
    Bao, Tao
    Zhang, Juan
    MICROCHIMICA ACTA, 2019, 186 (06)
  • [30] Development of hydrophilic magnetic molecularly imprinted polymers for the dispersive solid-phase extraction of sulfonamides from animal-derived samples before HPLC detection
    Zhao, Xiaolei
    Lu, Lei
    Zhu, Mengzhen
    Liu, Huilin
    He, Jinxing
    Zheng, Fuping
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (12) : 2399 - 2407