Cellulose-based laser-induced graphene devices for electrochemical monitoring of bacterial phenazine production and viability

被引:11
作者
Butler, Derrick [1 ,2 ]
Kammarchedu, Vinay [1 ,2 ,3 ]
Zhou, Keren [1 ]
Peeke, Lachlan [4 ,5 ]
Lyle, Luke [4 ,5 ]
Snyder, David W. [4 ,5 ,6 ]
Ebrahimi, Aida [1 ,2 ,3 ,7 ]
机构
[1] Penn State Univ, Dept Elect Engn, University Pk, PA 16802 USA
[2] Penn State Univ, Ctr Atom Thin Multifunct Coatings, University Pk, PA 16802 USA
[3] Penn State Univ, Ctr Biodevices, University Pk, PA 16802 USA
[4] Penn State Univ, Elect Mat & Devices Dept, Appl Res Lab, University Pk, PA 16802 USA
[5] Penn State Univ, Dept Mat Sci & Engn, University Pk, PA 16802 USA
[6] Penn State Univ, Dept Chem Engn, University Pk, PA 16802 USA
[7] Penn State Univ, Dept Biomed Engn, University Pk, PA 16802 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Cellulose; Paper-based analytical device; Laser-induced graphene; Bacteria; Viability; Phenazine; RAMAN-SPECTROSCOPY; PAPER; ELECTRODE; CARBON;
D O I
10.1016/j.snb.2022.133090
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As an easily disposable substrate with a microporous texture, paper is a well-suited, generic substrate to build analytical devices for studying bacteria. Using a multi-pass lasing process, cellulose-based laser-induced graphene (cLIG) with a sheet resistance of 43.7 +/- 2.3 omega sq-1 is developed and utilized in the fabrication of low-cost and environmentally-friendly paper-based sensor arrays. Two case studies with Pseudomonas aeruginosa and Escherichia coli demonstrate the practicality of the cLIG sensors for the electrochemical analysis of bacteria. The first study measures the time-dependent profile of phenazines, such as pyocyanin, released from both planktonic (up to 60 h) and on-chip-grown (up to 22 h) Pseudomonas aeruginosa cultures. While similarities do exist, marked differences in phenazine production are seen with cells grown directly on cLIG compared to the planktonic culture. Moreover, in planktonic cultures, pyocyanin levels increase early on and plateau around 20 h, while optical density measurements increase monotonically over the duration of testing. The second study monitors the viability and metabolic activity of Escherichia coli using a resazurin-based electrochemical assay. These results demonstrate the utility of cLIG-based sensors as an inexpensive and versatile platform for monitoring bacteria and could enable new opportunities in high-throughput antibiotic susceptibility testing, ecological studies, and biofilm studies.
引用
收藏
页数:12
相关论文
共 78 条
[31]   A Raman spectroscopic investigation of graphite oxide derived graphene [J].
Kaniyoor, Adarsh ;
Ramaprabhu, Sundara .
AIP ADVANCES, 2012, 2 (03)
[32]   RESISTIVE ELECTRODE EFFECTS ON CYCLIC VOLTAMMETRY [J].
KEIL, RG .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1986, 133 (07) :1375-1379
[33]  
Khan Z.A., 2019, Diagnostics, P9
[34]   One-step sensing of foodborne pathogenic bacteria using a 3D paper-based device [J].
Kim, Hyeok Jung ;
Kwon, Chanho ;
Lee, Byung Sub ;
Noh, Hyeran .
ANALYST, 2019, 144 (07) :2248-2255
[35]   Laser-induced graphene from paper for non-enzymatic uric acid electrochemical sensing in urine [J].
Kulyk, Bohdan ;
Pereira, Sonia O. ;
Fernandes, Antonio J. S. ;
Fortunato, Elvira ;
Costa, Florinda M. ;
Santos, Nuno F. .
CARBON, 2022, 197 :253-263
[36]   Conversion of paper and xylan into laser-induced graphene for environmentally friendly sensors [J].
Kulyk, Bohdan ;
Matos, Marina ;
Silva, Beatriz F. R. ;
Carvalho, Alexandre F. ;
Fernandes, Antonio J. S. ;
Evtuguin, Dmitry, V ;
Fortunato, Elvira ;
Costa, Florinda M. .
DIAMOND AND RELATED MATERIALS, 2022, 123
[37]   Laser-Induced Graphene from Paper for Mechanical Sensing [J].
Kulyk, Bohdan ;
Silva, Beatriz F. R. ;
Carvalho, Alexandre F. ;
Silvestre, Sara ;
Fernandes, Antonio J. S. ;
Martins, Rodrigo ;
Fortunato, Elvira ;
Costa, Florinda M. .
ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (08) :10210-10221
[38]   Electrochemical Detection of Pathogenic Bacteria-Recent Strategies, Advances and Challenges [J].
Kuss, Sabine ;
Amin, Hatem M. A. ;
Compton, Richard G. .
CHEMISTRY-AN ASIAN JOURNAL, 2018, 13 (19) :2758-2769
[39]   Simpler Procedure and Improved Performance for Pathogenic Bacteria Analysis with a Paper-Based Ratiometric Fluorescent Sensor Array [J].
Laliwala, Aayushi ;
Svechkarev, Denis ;
Sadykov, Marat R. ;
Endres, Jennifer ;
Bayles, Kenneth W. ;
Mohs, Aaron M. .
ANALYTICAL CHEMISTRY, 2022, 94 (05) :2615-2624
[40]   An extended method for the practical evaluation of the standard rate constant from cyclic voltammetric data [J].
Lavagnini, I ;
Antiochia, R ;
Magno, F .
ELECTROANALYSIS, 2004, 16 (06) :505-506