First microdosimetric measurements with a tissue-equivalent proportional counter at the MedAustron ion-beam therapy facility

被引:2
|
作者
Barna, Sandra [1 ,2 ]
Meouchi, Cynthia
Magrin, Giulio [3 ]
Bianchi, Anna [4 ]
Conte, Valeria [4 ]
Selva, Anna [4 ]
Stock, Markus [3 ]
Resch, Andreas Franz
Georg, Dietmar [1 ,2 ,3 ]
Palmans, Hugo [3 ,5 ]
机构
[1] Med Univ Vienna, Dept Radiat Oncol, A-1090 Vienna, Austria
[2] Tech Univ Wien, Radiat Phys, A-1040 Vienna, Austria
[3] MedAustron Ion Therapy Ctr, A-2700 Wiener Neustadt, Austria
[4] Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-20133 Legnaro, Italy
[5] Natl Phys Lab, Teddington TW11 0LW, Middx, England
基金
奥地利科学基金会;
关键词
CALIBRATION;
D O I
10.1093/rpd/ncac252
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this work is to present the first microdosimetric spectra measured with a miniaturised tissue-equivalent proportional counter in the clinical environment of the MedAustron ion-beam therapy facility. These spectra were gathered with a 62.4-MeV proton beam and have been compared with microdosimetric spectra measured in the 62-MeV clinical proton beam of the CATANA beam line. Monte Carlo simulations were performed using the Geant4 toolkit GATE and a fully commissioned clinical beam line model. Finally, similarities and discrepancies of the measured data to simulations based on a simple and complex detector geometry are discussed.
引用
收藏
页码:1973 / 1978
页数:6
相关论文
共 50 条
  • [1] Microdosimetry with tissue-equivalent proportional counters at an ion beam therapy facility
    Barna, S.
    Meouchi, C.
    Magrin, G.
    Conte, V.
    Stock, M.
    Resch, A.
    Georg, D.
    Palmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S735 - S736
  • [2] Microdosimetric measurements at FiR 1 using tissue equivalent proportional counter
    Uusi-Simola, J
    Seppälä, T
    Kosunen, A
    Savolainen, S
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 379 - 381
  • [3] Performance tests and comparison of microdosimetric measurements with four tissue-equivalent proportional counters in scanning proton therapy
    Farah, J.
    De Saint-Hubert, M.
    Mojzeszek, N.
    Chiriotti, S.
    Gryzinski, M.
    Ploc, O.
    Trompier, F.
    Turek, K.
    Vanhavere, F.
    Olko, P.
    RADIATION MEASUREMENTS, 2017, 96 : 42 - 52
  • [4] Optimized design of tissue-equivalent proportional counter
    Zhang, Wei-Hua
    Wang, Zhi-Qiang
    Xiao, Xue-Fu
    Liu, Yi-Na
    Li, Chun-Juan
    Luo, Hai-Long
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 (05): : 930 - 933
  • [5] MICRODOSIMETRIC MEASUREMENTS OF A TISSUE-EQUIVALENT PROPORTIONAL COUNTER BASED ON A GAS ELECTRON MULTIPLIER DOWN TO 140 NM SIMULATED SITE SIZES
    Farahmand, M.
    De Nardo, L.
    RADIATION PROTECTION DOSIMETRY, 2016, 171 (03) : 304 - 312
  • [6] MICRODOSIMETRIC MEASUREMENT OF SECONDARY RADIATION IN THE PASSIVE SCATTERED PROTON THERAPY ROOM OF iTHEMBA LABS USING A TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    Chiriotti, S.
    Parisi, A.
    Vanhavere, F.
    De Saint-Hubert, M.
    Vandevoorde, C.
    Slabbert, J.
    Beukes, P.
    de Kock, E.
    Symons, J.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (02) : 252 - 257
  • [7] Measurement of microdosimetric spectra with a wall-less tissue-equivalent proportional counter for a 290 MeV/u 12C beam
    Tsuda, Shuichi
    Sato, Tatsuhiko
    Takahashi, Fumiaki
    Satoh, Daiki
    Endo, Akira
    Sasaki, Shinichi
    Namito, Yoshihito
    Iwase, Hiroshi
    Ban, Shuichi
    Takada, Masashi
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17): : 5089 - 5101
  • [8] UNIVERSAL EQUIDOSIMETER BASED ON A TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    GARTSHTEIN, AI
    MAKOVSKII, YE
    FILYUSHKIN, IV
    MEASUREMENT TECHNIQUES, 1981, 24 (04) : 328 - 330
  • [9] Geant4 Monte Carlo simulations of a microdosimetric Tissue Equivalent Proportional Counter for carbon ion therapy
    Galer, S.
    Shipley, D.
    Hao, L.
    Palmans, H.
    Kirkby, K.
    Nisbet, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S59 - S60
  • [10] DESIGN, CONSTRUCTION, AND IMPLEMENTATION OF SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    Perez-Nunez, Delia
    Braby, Leslie A.
    NUCLEAR TECHNOLOGY, 2009, 168 (01) : 21 - 28