LC-MS/MS Investigation of nitrosamine impurities in certain Sartan group medicinal products available in Istanbul, Türkiye

被引:31
作者
Oncu, Tuna [1 ]
Yuksel, Bayram [2 ]
Binay, Emrullah [3 ]
Sen, Nilgun [4 ]
机构
[1] Shimadzu Middle East Africa, Istanbul, Turkiye
[2] Giresun Univ, TR-28600 Espiye, Giresun, Turkiye
[3] Istanbul Univ, Fac Pharmaceut Sci, Istanbul, Turkiye
[4] Turkish Natl Police Acad, Inst Forens Sci, Ankara, Turkiye
来源
ANNALES PHARMACEUTIQUES FRANCAISES | 2024年 / 82卷 / 01期
关键词
LC-MS/MS; Nitrosamines; Pharmaceutical analysis; Sartan medications; Validation; ANALYTICAL-CHEMISTRY; VALIDATION; LINEARITY; RECALLS;
D O I
10.1016/j.pharma.2023.08.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Nitrosamines (NAs) are molecules that include the nitroso functional group. In 2018, the US Food and Drug Administration (FDA) received its first report of NAs in pharmaceuticals. The fact that NA impurities are likely human carcinogens is relevant to these compounds. Furthermore, prolonged exposure to NA contaminants above safe limits may raise the risk of cancer. The goal of this article was to assess the amounts of six different NAs in Sartan group medicines purchased from formal pharmacies in Istanbul, Turkiye, using a validated LC-MS/MS assay. An LC-MS/MS-based analytical assay was undertaken. The separation was performed with a HR ODS 150 mm x 3.0 mm and 5 -analytical columns, providing effective separation of major peaks from NA impurities. In mobile phase A, formic acid was 0.10% in water, while in mobile phase B, formic acid was 0.10% in methanol. The flow rate was 0.4 mL/minute, and the total runtime was 18 minutes with the gradient elution mode. The validation was conducted in line with ISO/IEC 17025 requirements. Up to 100 pg/L, linearity was determined using correlation coefficients (r(2) > 0.995) for all NAs. The limit of quantification values for all NAs analyses were below 1.0 mu g/L. The mean recovery value obtained during the spike experiment was 95.18%, demonstrating the accuracy of the procedure. In addition, the accuracy was shown by a certified reference analysis, which yielded relative standard deviation and relative error values of 1.82% and 3.34%, respectively. During the intermediate precision testing, bias and relative standard deviation were 0.96 and 2.87%, respectively. Of the 75 study samples involving Sartan group medical products, no nitrosamine impurities were detected, demonstrating that pharmaceutical companies have adequate medication safety precautions in place in accordance with FDA and European Medicines Agency (EMA) regulations published to prevent NA contaminants in human medicinal products. (c) 2023 Academie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:72 / 83
页数:12
相关论文
共 53 条
[1]   ICP-MS Determination of Lead Levels in Autopsy Liver Samples: An Application in Forensic Medicine [J].
Arica, Enes ;
Yuksel, Bayram ;
Yener, Ismail ;
Dolak, Ibrahim ;
Gok, Ertugrul ;
Yilmaz, Eyup .
ATOMIC SPECTROSCOPY, 2018, 39 (02) :62-66
[2]   Accuracy, precision, and reliability of chemical measurements in natural products research [J].
Betz, Joseph M. ;
Brown, Paula N. ;
Roman, Mark C. .
FITOTERAPIA, 2011, 82 (01) :44-52
[3]   Critical Analysis of Drug Product Recalls due to Nitrosamine Impurities [J].
Bharate, Sonali S. .
JOURNAL OF MEDICINAL CHEMISTRY, 2021, 64 (06) :2923-2936
[4]  
Bozalan M., 2019, Turk Hijyen ve Deneysel Biyoloji Dergisi, V76, P243, DOI [10.5505/turkhijyen.2019.58234, 10.5505/TurkHijyen.2019.58234]
[5]   Hypertension Hot Potato - Anatomy of the Angiotensin-Receptor Blocker Recalls [J].
Byrd, J. Brian ;
Chertow, Glenn M. ;
Bhalla, Vivek .
NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (17) :1589-1591
[6]   Quantification of pesticides in food crops using QuEChERS approaches and GC-MS/MS [J].
Cho, Jimi ;
Lee, Jonghwa ;
Lim, Chai-Uk ;
Ahn, Jongsung .
Food Additives and Contaminants Part A-Chemistry Analysis Control Exposure & Risk Assessment, 2016, 33 (12) :1803-1816
[7]   Multiresidue analysis of pesticides in four different pomegranate cultivars: Investigating matrix effect variability by GC-MS/MS and LC-MS/MS [J].
Damale, Rahul D. ;
Dutta, Anirban ;
Shaikh, Nasiruddin ;
Pardeshi, Anita ;
Shinde, Raviraj ;
Babu, K. Dhinesh ;
Gaikwad, Nilesh N. ;
Banerjee, Kaushik .
FOOD CHEMISTRY, 2023, 407
[8]   Selectivity in analytical chemistry: Two interpretations for univariate methods [J].
Dorko, Zsanett ;
Verbic, Tatjana ;
Horvai, George .
TALANTA, 2015, 132 :680-684
[9]   Estimation of nizatidine gastric nitrosatability and product toxicity via an integrated approach combining HILIC, in silico toxicology, and molecular docking [J].
El-Shaheny, Rania ;
Radwan, Mohamed ;
Yamada, Koji ;
El-Maghrabey, Mahmoud .
JOURNAL OF FOOD AND DRUG ANALYSIS, 2019, 27 (04) :915-925
[10]  
European Medicines Agency, ICH Guideline Q14 on Analytical Procedure Development Step 2b