Modelling and real-time dynamic simulation of flexible needles for prostate biopsy and brachytherapy

被引:4
作者
Martsopoulos, Athanasios [1 ,2 ]
Hill, Thomas L. L. [1 ]
Persad, Rajendra [3 ]
Bolomytis, Stefanos [3 ]
Tzemanaki, Antonia [1 ,2 ]
机构
[1] Univ Bristol, Sch Civil Aerosp & Mech Engn, Bristol, England
[2] Dept Med Robot, Bristol Robot Lab, Bristol, England
[3] Southmead Hosp, Bristol Urol Inst, Bristol, England
基金
英国工程与自然科学研究理事会;
关键词
Surgery simulation; needle insertion; flexible multibody dynamics; rigid finite element method; NODAL COORDINATE FORMULATION; FINITE-ELEMENT; TISSUE INTERACTION; INSERTION METHODS; BEAM ELEMENTS; SOFT-TISSUES; DEFLECTION; DEFORMATION; FRICTION; FORCES;
D O I
10.1080/13873954.2022.2158875
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Percutaneous needle insertion constitutes a widely adopted technique for performing minimally invasive operations. Robot-assisted needle placement and virtual surgical training platforms have the potential to significantly improve the accuracy of these operations. For this, the development of mathematical models that provide a complete characterization of the underlying dynamics of medical needles is considered of paramount importance. In this paper, we develop two three-dimensional nonlinear rigid/flexible dynamic models of brachytherapy and local anaesthetic transperineal biopsy (LATP) needles. The proposed models relax the assumptions of previous investigations, quantify the vibrational behaviour and the rigid-body dynamics of medical needles and allow for real-time haptic and visual feedback information. Their accuracy and computational efficiency are assessed and validated using commercial software. The results show that, among the examined methods, the Rigid Finite Element Method provides the most accurate and numerically efficient solution for capturing the dynamics of flexible medical needles.
引用
收藏
页码:1 / 40
页数:40
相关论文
共 84 条
[1]  
Abayazid M, 2013, IEEE INT CONF ROBOT, P5843, DOI 10.1109/ICRA.2013.6631418
[2]   Effects of different insertion methods on reducing needle deflection [J].
Abolhassani, Niki ;
Patel, Rajni ;
Ayazi, Farzam .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :491-+
[3]   Minimization of needte deflection in robot-assisted percutaneous therapy [J].
Abolhassani, Niki ;
Patel, Rajni V. ;
Ayazi, Farzam .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (02) :140-148
[4]   Needle insertion into soft tissue: A survey [J].
Abolhassani, Niki ;
Patel, Rajni ;
Moallem, Mehrdad .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (04) :413-431
[5]   Robotic Insertion of Flexible Needle in Deformable Structures Using Inverse Finite-Element Simulation [J].
Adagolodjo, Yinoussa ;
Goffin, Laurent ;
De Mathelin, Michel ;
Courtecuisse, Hadrien .
IEEE TRANSACTIONS ON ROBOTICS, 2019, 35 (03) :697-708
[6]   Modelling of Ropes with Consideration of Large Deformations and Friction by Means of the Rigid Finite Element Method [J].
Adamiec-Wojcik, Iwona ;
Awrejcewicz, Jan ;
Brzozowska, Lucyna ;
Drag, Lukasz .
APPLIED NON-LINEAR DYNAMICAL SYSTEMS, 2014, 93 :115-137
[7]  
Asadian A, 2011, IEEE INT C INT ROBOT
[8]  
Asadian A, 2011, IEEE INT CONF ROBOT, P1896
[9]   A Compact Dynamic Force Model for Needle-Tissue Interaction [J].
Asadian, Ali ;
Kermani, Mehrdad R. ;
Patel, Rajni V. .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :2292-2295
[10]   Does needle rotation improve lesion targeting? [J].
Badaan, Shadi ;
Petrisor, Doru ;
Kim, Chunwoo ;
Mozer, Pierre ;
Mazilu, Dumitru ;
Gruionu, Lucian ;
Patriciu, Alex ;
Cleary, Kevin ;
Stoianovici, Dan .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2011, 7 (02) :138-147