Quick Quality Assessment and Radiometric Calibration of C-SAR/01 Satellite Using Flexible Automatic Corner Reflector

被引:11
作者
Huang, Qiqi [1 ,2 ]
Zhang, Fengli [1 ,2 ]
Li, Lu [1 ,2 ]
Liu, Xiaochen [1 ]
Jiao, Yanan [1 ,2 ]
Yuan, Xinzhe [3 ]
Li, Huirong [4 ]
机构
[1] Chinese Acad Sci, Aerosp Informat Res Inst, Beijing 100101, Peoples R China
[2] Univ Chinese Acad Sci, Coll Resources & Environm, Beijing 100049, Peoples R China
[3] Natl Satellite Ocean Applicat Serv, Beijing 100081, Peoples R China
[4] Xilinhot Natl Climat Observ, Xilinhot 026000, Peoples R China
关键词
C-SAR; 01; flexible automatic corner reflector; radiometric calibration; validation; SAR; STABILITY; ACCURACY;
D O I
10.3390/rs15010104
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
C-SAR/01, the successor of China's Gaofen-3 Satellite, which launched on 23 November 2021, is the first synthetic aperture radar (SAR) satellite to be launched in China's civil space infrastructure plan and has served as an invaluable data resource. Radiometric calibration and validation are prerequisites for the quantitative application of SAR data. In this study, the radiometric calibration experiments of C-SAR/01 data of the ultra-fine strip (UFS) and fine strip I (FSI) modes were conducted applying flexible automatic triangular trihedral corner reflectors deployed in Xilinhot SAR satellite calibration and validation site. Accordingly, the image quality and radiometric calibration accuracy were evaluated. The results show that the spatial resolution, peak sidelobe ratio, and integrated sidelobe ratio of UFS and FSI mode data of C-SAR/01 are better than those of the design indexes, and the calibration results from the integral method are more stable than those from the peak method. Furthermore, the standard deviation of the calibration constant for UFS mode data is 0.234 dB, with the relative and absolute calibration accuracies obtained as 0.233 and 0.532 dB, respectively, whereas the standard deviation calibration constant for FSI mode data is 0.198 dB, with its relative and absolute calibration accuracies evaluated as 0.199 and 0.333 dB, respectively.
引用
收藏
页数:20
相关论文
共 28 条
[1]  
[Anonymous], 2014, INT J ADV ENG RES SC
[2]   Polarimetric Calibration and Quality Assessment of the GF-3 Satellite Images [J].
Chang, Yonglei ;
Li, Pingxiang ;
Yang, Jie ;
Zhao, Jinqi ;
Zhao, Lingli ;
Shi, Lei .
SENSORS, 2018, 18 (02)
[3]  
Cumming I. G., 2005, ARTECH REM, V1, P108
[4]  
Doerry A.W., 2008, Reflectors for SAR Performance Testing
[5]  
Dring B., 2007, P WAVE PROPAGATION C, P86
[6]   Airborne SAR radiometric calibration using point targets [J].
Feng Zongmin ;
Huang Lei ;
Tang Zhihua ;
Liu Jiuli ;
Zhao Liangbo .
35TH INTERNATIONAL SYMPOSIUM ON REMOTE SENSING OF ENVIRONMENT (ISRSE35), 2014, 17
[7]   SAR CALIBRATION - AN OVERVIEW [J].
FREEMAN, A .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1992, 30 (06) :1107-1121
[8]   In-Depth Verification of Sentinel-1 and TerraSAR-X Geolocation Accuracy Using the Australian Corner Reflector Array [J].
Gisinger, Christoph ;
Schubert, Adrian ;
Breit, Helko ;
Garthwaite, Matthew ;
Balss, Ulrich ;
Willberg, Martin ;
Small, David ;
Eineder, Michael ;
Miranda, Nuno .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2021, 59 (02) :1154-1181
[9]   SYNTHETIC APERTURE RADAR CALIBRATION USING REFERENCE REFLECTORS [J].
GRAY, AL ;
VACHON, PW ;
LIVINGSTONE, CE ;
LUKOWSKI, TI .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1990, 28 (03) :374-383
[10]  
Kuang G., 2007, SYNTHETIC APERTURE R