Exposure Monitoring Strategies for Applying Low-Cost PM Sensors to Assess Flour Dust in Industrial Bakeries

被引:7
作者
Ruiter, Sander [1 ]
Bard, Delphine [2 ]
Ben Jeddi, Hasnae [1 ]
Saunders, John
Snawder, John [3 ]
Warren, Nick [2 ]
Gorce, Jean-Philippe [2 ]
Cauda, Emanuele [3 ]
Kuijpers, Eelco [1 ]
Pronk, Anjoeka [1 ]
机构
[1] Netherlands Org Appl Sci Res TNO, Hlth Living & Work, RAPID, NL-3584 CB Utrecht, Netherlands
[2] HSE Sci & Res Ctr, Hlth & Safety Execut HSE, Harpur Hill, Buxton SK17 9JN, England
[3] Ctr Dis Control & Prevent, NIOSH, 1090 Tusculum Ave, Cincinnati, OH 45226 USA
关键词
bakery; exposure; flour dust; low-cost devices; monitors; occupational; particulate matter (PM); sensors; TIME;
D O I
10.1093/annweh/wxac088
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Low-cost particulate matter (PM) sensors provide new methods for monitoring occupational exposure to hazardous substances, such as flour dust. These devices have many possible benefits, but much remains unknown about their performance for different exposure monitoring strategies in the workplace. We explored the performance of PM sensors for four different monitoring strategies (time-weighted average and high time resolution, each quantitative and semi-quantitative) for assessing occupational exposure using low-cost PM sensors in a field study in the industrial bakery sector. Measurements were collected using four types of sensor (PATS+, Isensit, Airbeam2, and Munisense) and two reference devices (respirable gravimetric samplers and an established time-resolved device) at two large-scale bakeries, spread over 11 participants and 6 measurement days. Average PM2.5 concentrations of the low-cost sensors were compared with gravimetric respirable concentrations for 8-h shift periods and 1-min PM2.5 concentrations of the low-cost sensors were compared with time-resolved PM2.5 data from the reference device (quantitative monitoring strategy). Low-cost sensors were also ranked in terms of exposure for 8-h shifts and for 15-min periods with a shift (semi-quantitative monitoring strategy). Environmental factors and methodological variables, which can affect sensor performance, were investigated. Semi-quantitative monitoring strategies only showed more accurate results compared with quantitative strategies when these were based on shift-average exposures. The main factors that influenced sensor performance were the type of placement (positioning the devices stationary versus personal) and the company or workstation where measurements were collected. Together, these findings provide an overview of common strengths and drawbacks of low-cost sensors and different ways these can be applied in the workplace. This can be used as a starting point for further investigations and the development of guidance documents and data analysis methods.
引用
收藏
页码:379 / 391
页数:13
相关论文
共 29 条
[1]  
American Industrial Hygiene Association, 2016, FUT SENS PROT WORK H, P6
[2]  
[Anonymous], 2014, Guidelines for Canadian Drinking Water Quality-Summary Table, P1
[3]   Effectiveness of interventions to reduce flour dust exposures in supermarket bakeries in South Africa [J].
Baatjies, Roslynn ;
Meijster, Tim ;
Heederik, Dick ;
Sander, Ingrid ;
Jeebhay, Mohamed F. .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2014, 71 (12) :811-818
[4]   Fitting Linear Mixed-Effects Models Using lme4 [J].
Bates, Douglas ;
Maechler, Martin ;
Bolker, Benjamin M. ;
Walker, Steven C. .
JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01) :1-48
[5]   The Occupational Burden of Nonmalignant Respiratory Diseases An Official American Thoracic Society and European Respiratory Society Statement [J].
Blanc, Paul D. ;
Annesi-Maesano, Isabella ;
Balmes, John R. ;
Cummings, Kristin J. ;
Fishwick, David ;
Miedinger, David ;
Murgia, Nicola ;
Naidoo, Rajen N. ;
Reynolds, Carl J. ;
Sigsgaard, Torben ;
Toren, Kjell ;
Vinnikov, Denis ;
Redlich, Carrie A. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199 (11) :1312-1334
[6]   Personal exposure to UFP in different micro-environments and time of day [J].
de Kluizenaar, Y. ;
Kuijpers, E. ;
Eekhout, I. ;
Voogt, M. ;
Vermeulen, R. C. H. ;
Hoek, G. ;
Sterkenburg, R. P. ;
Pierik, F. H. ;
Duyzer, J. H. ;
Meijer, E. W. ;
Pronk, A. .
BUILDING AND ENVIRONMENT, 2017, 122 :237-246
[7]   Global and regional burden of disease and injury in 2016 arising from occupational exposures: a systematic analysis for the Global Burden of Disease Study 2016 [J].
Driscoll, Tim ;
Rushton, Lesley ;
Hutchings, Sally J. ;
Straif, Kurt ;
Steenland, Kyle ;
Abate, Degu ;
Abbafat, Cristiana ;
Acharya, Dilaram ;
Adebayo, Oladimeji M. ;
Afshari, Mahdi ;
Akinyemiju, Tomi ;
Alahdab, Fares ;
Anjomshoa, Mina ;
Antonio, Carl Abelardo T. ;
Aremu, Olatunde ;
Ataro, Zerihun ;
Quintanilla, Beatriz Paulina Ayala ;
Banoub, Joseph Adel Mattar ;
Barker-Collo, Suzanne Lyn ;
Barnighausen, Till Winfried ;
Barrero, Lope H. ;
Bedi, Neeraj ;
Behzadifar, Masoud ;
Behzadifar, Meysam ;
Benavides, Fernando G. ;
Beuran, Mircea ;
Bhattacharyya, Krittika ;
Bijani, Ali ;
Cardenas, Rosario ;
Carrero, Juan J. ;
Carvalho, Felix ;
Castaneda-Orjuela, Carlos A. ;
Cerin, Ester ;
Cooper, Cyrus ;
Dandona, Lalit ;
Dandona, Rakhi ;
Dang, Anh Kim ;
Daryani, Ahmad ;
Desalegn, Beruk Berhanu ;
Dharmaratne, Samath Dhamminda ;
Dubljanin, Eleonora ;
El-Khatib, Ziad ;
Eskandarieh, Sharareh ;
Fareed, Mohammad ;
Faro, Andre ;
Fereshtehnejad, Seyed-Mohammad ;
Fernandes, Eduarda ;
Filip, Irina ;
Fischer, Florian ;
Fukumoto, Takeshi .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2020, 77 (03) :133-141
[8]   Future Prospects of Occupational Exposure Modelling of Substances in the Context of Time-Resolved Sensor Data Comment [J].
Goede, Henk ;
Kuijpers, Eelco ;
Krone, Tanja ;
le Feber, Maaike ;
Franken, Remy ;
Fransman, Wouter ;
Duyzer, Jan ;
Pronk, Anjoeka .
ANNALS OF WORK EXPOSURES AND HEALTH, 2021, 65 (03) :246-254
[9]   Advanced sensor technologies and the future of work [J].
Howard, John ;
Murashov, Vladimir ;
Cauda, Emanuele ;
Snawder, John .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2022, 65 (01) :3-11
[10]   Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements [J].
Huang, Ching-Hsuan ;
He, Jiayang ;
Austin, Elena ;
Seto, Edmund ;
Novosselov, Igor .
PLOS ONE, 2021, 16 (11)