Effect of Carbon Fiber Reinforced Peek on Stabilization of Sagittal Split Ramus Osteotomy Fixation and Stresses on Temporomandibular Joint: 3d Finite Element Analysis Study

被引:1
作者
Erdem, Musa [1 ]
Bas, Mehmet Zahit [2 ]
机构
[1] Uskudar Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Saray Mahallesi Ahmet Tevfik Ileri Caddesi 5, Istanbul, Turkiye
[2] Univ Hlth Sci, Fac Dent, Dept Oral & Maxillofacial Surg, Selimiye Mah Tibbiye Cad 38, TR-34668 Istanbul, Turkiye
关键词
Sagittal split ramus osteotomy; Fixation; CFR-PEEK; Stability; Finite element analysis; MANDIBULAR ADVANCEMENT; INTERNAL-FIXATION; STABILITY; POLYETHERETHERKETONE; MINIPLATE; POLYMER;
D O I
10.1007/s40846-023-00843-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeThis study aimed to compare carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates and screws with conventional titanium plates and screws for mandibular orthognathic surgery models.MethodsSagittal split ramus osteotomy (SSRO) was simulated in a 3D finite element model of the mandible. Eight fixation groups with 3 different designs (miniplate, hybrid, and inverted-L) were created using titanium and CFR-PEEK materials. The displacement values in the osteotomy lines, the von Mises stress values on the fixation devices, and the maximum tensile and compressive stress values on the bone in contact with the screws and the temporomandibular joints (TMJ) were compared.ResultsThe displacement in the osteotomy line in the models using the CFR-PEEK polymer was higher than in the titanium models. The stress on the miniplate and screws in the CFR-PEEK models was lower than that in the titanium models. The maximum stress on the miniplates was found close to the fracture line in the distal segment. The stress on the TMJ of the CFR-PEEK models was higher than that of the titanium models.When the fixation designs were compared regardless of the material, the lowest displacement value (CFR-PEEK: 0.268 mm; Titanium: 0.253 mm), the highest screw stress (CFR-PEEK: 372.9 MPa; Titanium: 1185.5 MPa), and the lowest bone stress (CFR-PEEK: 57.216 MPa; Titanium:64.022 MPa) were observed in the models using the inverted-L technique for fixation.ResultsThe displacement in the osteotomy line in the models using the CFR-PEEK polymer was higher than in the titanium models. The stress on the miniplate and screws in the CFR-PEEK models was lower than that in the titanium models. The maximum stress on the miniplates was found close to the fracture line in the distal segment. The stress on the TMJ of the CFR-PEEK models was higher than that of the titanium models.When the fixation designs were compared regardless of the material, the lowest displacement value (CFR-PEEK: 0.268 mm; Titanium: 0.253 mm), the highest screw stress (CFR-PEEK: 372.9 MPa; Titanium: 1185.5 MPa), and the lowest bone stress (CFR-PEEK: 57.216 MPa; Titanium:64.022 MPa) were observed in the models using the inverted-L technique for fixation.ConclusionThe results suggest that CFR-PEEK plates and screws reduce stress on the fixation systems and the associated bone while increasing stress on the TMJ.
引用
收藏
页码:12 / 23
页数:12
相关论文
共 35 条
[1]   Assessment of sagittal split ramus osteotomy rigid internal fixation techniques using a finite element method [J].
Albougha, S. ;
Darwich, K. ;
Darwich, M. A. ;
Albogha, M. H. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (07) :823-829
[2]   Evaluation of the rigidity of sagittal split ramus osteotomy fixation using four designs of biodegradable and titanium plates—a numerical study [J].
Albougha S. ;
Albogha M.H. ;
Darwich M.A. ;
Darwich K. .
Oral and Maxillofacial Surgery, 2015, 19 (3) :281-285
[3]   Investigation of the biomechanical stability of Cfr-PEEK in the treatment of mandibular angulus fractures by finite element analysis [J].
Avci, Tolunay ;
Omezli, Mehmet Melih ;
Torul, Damla .
JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2022, 123 (06) :610-615
[4]  
Bloomquist DS., 2022, PETERSONS PRINCIPLES, P1851, DOI [10.1007/978-3-030-91920-7_62, DOI 10.1007/978-3-030-91920-7_62]
[5]   Comparison of bicortical, miniplate and hybrid fixation techniques in mandibular advancement and counterclockwise rotation: A finite element analysis study [J].
Can, Serhat ;
Basa, Selcuk ;
Varol, Altan .
JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) :E7-E14
[6]   Evaluation of Stress Distribution in Resorbable Screw Fixation System: Three-Dimensional Finite Element Analysis of Mandibular Setback Surgery With Bilateral Sagittal Split Ramus Osteotomy [J].
Choi, Jae-Pyong ;
Baek, Seung-Hak ;
Choi, Jin-Young .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (04) :1104-1109
[7]   Using Single Miniplate in Mandibular Angle Fractures: Finite Elements Analysis [J].
Erdogan, Mehmet Mustafa ;
Simsek, Tugce ;
Ugur, Levent .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (04) :479-487
[8]   Performance study of braided carbon/PEEK composite compression bone plates [J].
Fujihara, K ;
Huang, ZM ;
Ramakrishna, S ;
Satknanantham, K ;
Hamada, H .
BIOMATERIALS, 2003, 24 (15) :2661-2667
[9]   Biodegradable versus titanium osteosynthesis in maxillofacial traumatology: a systematic review with meta-analysis and trial sequential analysis [J].
Gareb, B. ;
van Bakelen, N. B. ;
Dijkstra, P. U. ;
Vissink, A. ;
Bos, R. R. M. ;
van Minnen, B. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (07) :914-931
[10]   Do mandibular miniplates increase the risk of complex fracture in facial trauma recurrence? Case series [J].
Graillon, Nicolas ;
Guyot, Laurent ;
Sigaux, Nicolas ;
Louvrier, Aurelien ;
Trost, Olivier ;
Lutz, Jean-Christophe ;
Foletti, Jean-Marc .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2021, 49 (07) :613-619