Accuracy of the SRK/T Formula in Pediatric Cataract Surgery

被引:2
作者
Irfani, Irawati [1 ,2 ]
Wahyu, Tri [1 ]
Oktarima, Primawita [1 ,2 ]
Caesarya, Sesy [1 ,2 ]
Sari, Maya [1 ,2 ]
Karfiati, Feti [1 ,2 ]
机构
[1] Univ Padjadjaran, Dept Ophthalmol, Fac Med, Bandung, West Java, Indonesia
[2] Cicendo Natl Eye Hosp, Pediat Ophthalmol & Strabismus Div, Bandung, West Java, Indonesia
来源
CLINICAL OPTOMETRY | 2023年 / 15卷
关键词
absolute prediction error; SRK; T formula; pediatric cataract; INTRAOCULAR-LENS IMPLANTATION; POWER CALCULATION; IMMERSION; CONTACT;
D O I
10.2147/OPTO.S390994
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Determining IOL power is an important step in achieving the desired postoperative refractive target, but this determination remains challenging, as currently the used formulas were developed using IOL power calculations derived from adults.Patients and Methods: This is a retrospective analytical study with the period of June 2018 to May 2019. All of the data were taken from medical records in referral tertiary eye hospital in Indonesia. All type of cataracts underwent uncomplicated surgeries and in-the-bag IOL implantation were included in this study, while aphakia, secondary IOL implantation, primary sulcus implantation, and history of ocular disorders were excluded. The data were analyzed using Wilcoxon sign-rank, paired t, and Kruskal-Wallis tests.Results: Sixty-seven patients (106 eyes) were found to meet the inclusion criteria, average age was 7.35 +/- 4.61 years (1.00 to 17.00 years). Average targeted refraction was 1.69 +/- 2.06 D (-0.38-+6.99 D), and spherical equivalent (actual postoperative refraction) was -0.90 +/- 1.45 D (-4.38 to +2.75 D). There was statistically significant difference between preoperative targeted refraction and actual postoperative refraction (p < 0.001). Mean absolute prediction error (APE) in general was 1.34 +/- 1.18 D, 1.22 +/- 0.88 D (in short eyes), 1.52 +/- 1.37 D (in moderate eyes), and 0.69 +/- 0.52 D (in long eyes) (p = 0.202). Mean APE in age group <7 years old was 1.27 +/- 1.18 D and >= 7 years-old was 1.42 +/- 1.19 D (p = 0.429).Conclusion: SRK/T formula is fairly accurate in calculating IOL power in pediatric cataract surgery. Mean APE in this study was within the range of accurate mean APE in pediatric patients despite differentiated axial length and age.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 26 条
  • [1] Update of intraocular lens implantation in children
    Al Shamrani, Mohammed
    Al Turkmani, Shahira
    [J]. SAUDI JOURNAL OF OPHTHALMOLOGY, 2012, 26 (03) : 271 - 275
  • [2] Accuracy of IOL calculations in children: A comparison of immersion versus contact A-scan biometery
    Ben-Zion, Itay
    Neely, Daniel E.
    Plager, David A.
    Ofner, Susan
    Sprunger, Derek T.
    Roberts, Gavin J.
    [J]. JOURNAL OF AAPOS, 2008, 12 (05): : 440 - 444
  • [3] Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients
    Chang, Pingjun
    Lin, Lei
    Li, Zhangliang
    Wang, Li
    Huang, Jinhai
    Zhao, Yun-e
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (05) : 1123 - 1131
  • [4] Surgery for sight: outcomes of congenital and developmental cataracts operated in Durban, South Africa
    Gogate, P.
    Parbhoo, D.
    Ramson, P.
    Budhoo, R.
    Overland, L.
    Mkhize, N.
    Naidoo, K.
    Levine, S.
    du Bryn, A.
    Benjamin, L.
    [J]. EYE, 2016, 30 (03) : 406 - 412
  • [5] Gupta R, 2016, J OPHTHALMOL, P250, DOI [10.7869/djo.184, DOI 10.7869/DJO.184]
  • [6] Indaram M, 2017, SEMIN OPHTHALMOL, V33, P1
  • [7] Joshi P, 2014, NEPAL J OPHTHALMOL, V6, P56, DOI 10.3126/nepjoph.v6i1.10773
  • [8] Pediatric cataract
    Khokhar, Sudarshan Kumar
    Pillay, Ganesh
    Dhull, Chirakshi
    Agarwal, Esha
    Mahabir, Manish
    Aggarwal, Pulak
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1340 - 1349
  • [9] Comparison of the Accuracy of IOL Power Calculation Formulas for Pediatric Eyes in Children of Different Ages
    Kou, Jiaojiao
    Chang, Pingjun
    Lin, Lei
    Li, Zhangliang
    Fu, Yana
    Zhao, Yun-e
    [J]. JOURNAL OF OPHTHALMOLOGY, 2020, 2020