Comparison of robot-assisted versus fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar spinal diseases: 2-year follow-up

被引:14
作者
Wang, Lianlei [1 ]
Li, Chao [1 ]
Wang, Zheng [1 ]
Li, Donglai [1 ]
Tian, Yonghao [1 ]
Yuan, Suomao [1 ]
Liu, Xinyu [1 ]
机构
[1] Shandong Univ, Dept Orthoped, Qilu Hosp, Wenhua West Rd 107, Jinan 250012, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Robot-assisted MIS-TLIF; Fluoroscopy-assisted MIS-TLIF; PURELY-FA MIS-TLIF; MINIMALLY-FA RA-MIS-TLIF; Degenerative spinal disease; PEDICLE SCREW PLACEMENT; FACET JOINT VIOLATIONS; ADJACENT SEGMENT DISEASE; PERCUTANEOUS PLACEMENT; ACCURACY; SYSTEM; FIXATION; INSTRUMENTATION; COMPLICATIONS; INSERTION;
D O I
10.1007/s11701-022-01442-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study was performed to prospectively compare the clinical and radiographic outcomes between robot-assisted minimally invasive transforaminal lumbar interbody fusion (RA MIS-TLIF) and fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion (FA MIS-TLIF) in patients with degenerative lumbar spinal diseases. One hundred and twenty-three patients with lumbar degenerative diseases (lumbar spinal stenosis with instability and spondylolisthesis [degenerative spondylolisthesis or isthmic spondylolisthesis]) who underwent MIS-TLIF in our hospital were included in this study. Sixty-one patients underwent RA MIS-TLIF (Group A) and 62 patients underwent FA MIS-TLIF (Group B). Group A was further divided into Subgroup AI (46 single-level procedures) and Subgroup AII (15 double-level procedures). Group B was further divided into Subgroup BI (45 single-level procedures) and Subgroup BII (17 double-level procedures). The clinical outcome parameters were the visual analog scale (VAS) score, Oswestry Disability Index (ODI) score, operative time, number of intraoperative fluoroscopies, blood loss, postoperative hospital stay, and postoperative complications. The radiographic change measures were the accuracy of screw placement, facet joint violation (FJV), fusion status, and change in disc height at the proximal adjacent segment at the 2-year follow-up. There were no significant differences in the VAS and ODI scores, blood loss, or postoperative hospital stay between Groups A and B (p > 0.05). The operative time was longer in Group A than B (p = 0.018). The operative time was longer in Subgroup AI than BI (p = 0.001). However, there was no significant difference between Subgroups AII and BII (p > 0.05). There was no significant difference in the number of intraoperative fluoroscopies for patients between Groups A and B (p > 0.05). Although the number of intraoperative fluoroscopies for patients was significantly higher in Subgroup AI than BI (p = 0.019), there was no significant difference between Subgroups AII and BII (p > 0.05). The number of intraoperative fluoroscopies for the surgeon was significantly lower in Group A than B (p < 0.001). For surgeons, the difference in the average number of intraoperative fluoroscopies between Subgroups AI and AII was 2.98, but that between Subgroups BI and BII was 10.73. In Group A, three guide pins exhibited drift and one patient developed a lateral wall violation by a pedicle screw. One pedicle screw perforated the anterior wall of the vertebral body and another caused an inner wall violation in Group B. The rate of a perfect screw position (grade A) was higher in Group A than B (p < 0.001). However, there was no significant difference in the proportion of clinically acceptable screws (grades A and B) between the two groups. The mean FJV grade was significantly higher in Group B than A (p < 0.001). During at 2-year postoperative follow-up, there was no significant difference in the fusion status between the two groups (p > 0.05); however, the decrease in disc height at the proximal adjacent segment was significantly less in Group A than B (p < 0.001). Robot-assisted percutaneous pedicle screw placement is a safer and more accurate alternative to conventional freehand fluoroscopy-assisted percutaneous pedicle screw insertion in MIS-TLIF.
引用
收藏
页码:473 / 485
页数:13
相关论文
共 50 条
  • [21] Cantilever Transforaminal Lumbar Interbody Fusion for Upper Lumbar Degenerative Diseases (Minimum 2 Years Follow Up)
    Hioki, Akira
    Miyamoto, Kei
    Hosoe, Hideo
    Sugiyama, Seiichi
    Suzuki, Naoki
    Shimizu, Katsuji
    YONSEI MEDICAL JOURNAL, 2011, 52 (02) : 314 - 321
  • [22] Minimally Invasive Lumbar Decompression Versus Minimally Invasive Transforaminal Lumbar Interbody Fusion for Treatment of Low-Grade Lumbar Degenerative Spondylolisthesis
    Bovonratwet, Patawut
    Samuel, Andre M.
    Mok, Jung Kee
    Vaishnav, Avani S.
    Morse, Kyle W.
    Song, Junho
    Steinhaus, Michael E.
    Jordan, Yusef J.
    Gang, Catherine H.
    Qureshi, Sheeraz A.
    SPINE, 2022, 47 (21) : 1505 - 1514
  • [23] Comparison of bilateral versus unilateral decompression incision of minimally invasive transforaminal lumbar interbody fusion in two-level degenerative lumbar diseases
    Zhao, Yongzhao
    Zhu, Yanjie
    Zhang, Hailong
    Wang, Chuanfeng
    He, Shisheng
    Gu, Guangfei
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (12) : 2835 - 2842
  • [24] Minimally Invasive Lateral Lumbar Interbody Fusion Clinical and Radiographic Outcome at a Minimum 2-year Follow-up
    Kotwal, Suhel
    Kawaguchi, Satoshi
    Lebl, Darren
    Hughes, Alexander
    Huang, Russel
    Sama, Andrew
    Cammisa, Frank
    Girardi, Federico
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (04): : 119 - 125
  • [25] Minimally invasive transforaminal lumbar interbody fusion versus oblique lateral interbody fusion for lumbar degenerative disease: a meta-analysis
    Zhang, Qing-Yi
    Tan, Jie
    Huang, Kai
    Xie, Hui-Qi
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [26] Efficacy and safety of navigation robot-assisted versus conventional oblique lateral lumbar interbody fusion with internal fixation in the treatment of lumbar degenerative diseases: A retrospective study
    Tong, Min
    Zhang, Siping
    Zhang, Wenhao
    Mou, Limin
    Dong, Zhenyu
    Wang, Rong
    Li, Shida
    Huang, Yifei
    MEDICINE, 2024, 103 (32) : e39261
  • [27] Comparison of Postoperative Outcomes Between Percutaneous Endoscopic Lumbar Interbody Fusion and Minimally Invasive Transforaminal Lumbar Interbody Fusion for Lumbar Spinal Stenosis
    Lin, Lu
    Liu, Xiao-Qin
    Shi, Lei
    Cheng, Si
    Wang, Zhi-Qiang
    Ge, Qi-Jun
    Gao, Ding-Zhi
    Ismail, Amadou Cheffou
    Ke, Zhen-Yong
    Chu, Lei
    FRONTIERS IN SURGERY, 2022, 9
  • [28] Comparison of Lumbosacral Fusion Grade in Patients after Transforaminal and Anterior Lumbar Interbody Fusion with Minimum 2-Year Follow-Up
    Liu, Jinping
    Xie, Rong
    Chin, Cynthia T.
    Rajagopalan, Priya
    Duan, Ping-Guo
    Li, Bo
    Burch, Shane
    Berven, Sigurd H.
    Mummaneni, Praveen V.
    Chou, Dean
    ORTHOPAEDIC SURGERY, 2023, 15 (09) : 2334 - 2341
  • [29] Adjacent segment disease after minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar diseases: incidence and risk factors
    Yuan, Chao
    Zhou, Jing
    Wang, Liran
    Deng, Zhongliang
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [30] Instrumentation-related complications of lumbar degenerative disc diseases treated by minimally invasive transforaminal lumbar interbody fusion
    Xinyu Yang
    Xinyu Liu
    BrainScienceAdvances, 2019, 5 (03) : 213 - 219