Verification of neuronavigated TMS accuracy using structured-light 3D scans

被引:2
作者
Matilainen, Noora [1 ]
Kataja, Juhani [1 ]
Laakso, Ilkka [1 ,2 ]
机构
[1] Aalto Univ, Dept Elect Engn & Automat, Espoo, Finland
[2] Aalto Univ, Aalto Neuroimaging, Aalto, Finland
基金
芬兰科学院;
关键词
transcranial magnetic stimulation; dosimetric modelling; navigated TMS; navigation accuracy; landmark pointing; electric field; TRANSCRANIAL MAGNETIC STIMULATION; SURFACE-BASED ANALYSIS;
D O I
10.1088/1361-6560/ad33b8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To investigate the reliability and accuracy of the manual three-point co-registration in neuronavigated transcranial magnetic stimulation (TMS). The effect of the error in landmark pointing on the coil placement and on the induced electric and magnetic fields was examined. Approach. The position of the TMS coil on the head was recorded by the neuronavigation system and by 3D scanning for ten healthy participants. The differences in the coil locations and orientations and the theoretical error values for electric and magnetic fields between the neuronavigated and 3D scanned coil positions were calculated. In addition, the sensitivity of the coil location on landmark accuracy was calculated. Main results. The measured distances between the neuronavigated and 3D scanned coil locations were on average 10.2 mm, ranging from 3.1 to 18.7 mm. The error in angles were on average from two to three degrees. The coil misplacement caused on average a 29% relative error in the electric field with a range from 9% to 51%. In the magnetic field, the same error was on average 33%, ranging from 10% to 58%. The misplacement of landmark points could cause a 1.8-fold error for the coil location. Significance. TMS neuronavigation with three landmark points can cause a significant error in the coil position, hampering research using highly accurate electric field calculations. Including 3D scanning to the process provides an efficient method to achieve a more accurate coil position.
引用
收藏
页数:11
相关论文
共 30 条
[1]   A high-resolution computational localization method for transcranial magnetic stimulation mapping [J].
Aonuma, Shinta ;
Gomez-Tames, Jose ;
Laakso, Ilkka ;
Hirata, Akimasa ;
Takakura, Tomokazu ;
Tamura, Manabu ;
Muragaki, Yoshihiro .
NEUROIMAGE, 2018, 172 :85-93
[2]   Repetitive Transcranial Magnetic Stimulation for the Acute Treatment of Major Depressive Episodes A Systematic Review With Network Meta-analysis [J].
Brunoni, Andre R. ;
Chaimani, Anna ;
Moffa, Adriano H. ;
Razza, Lais B. ;
Gattaz, Wagner F. ;
Daskalakis, Zafiris J. ;
Carvalho, Andre F. .
JAMA PSYCHIATRY, 2017, 74 (02) :143-152
[3]   Where does TMS Stimulate the Motor Cortex? Combining Electrophysiological Measurements and Realistic Field Estimates to Reveal the Affected Cortex Position [J].
Bungert, Andreas ;
Antunes, Andre ;
Espenhahn, Svenja ;
Thielscher, Axel .
CEREBRAL CORTEX, 2017, 27 (11) :5083-5094
[4]   Neuronavigation maximizes accuracy and precision in TMS positioning: Evidence from 11,230 distance, angle, and electric field modeling measurements [J].
Caul, Kevin A. ;
Fleischmann, Holly H. ;
Cox, Claire E. ;
Wolf, Julia P. ;
George, Mark S. ;
McTeague, Lisa M. .
BRAIN STIMULATION, 2022, 15 (05) :1192-1205
[5]   Cortical surface-based analysis - I. Segmentation and surface reconstruction [J].
Dale, AM ;
Fischl, B ;
Sereno, MI .
NEUROIMAGE, 1999, 9 (02) :179-194
[6]   Accurate Coil Positioning is Important for Single and Paired Pulse TMS on the Subject Level [J].
de Goede, Annika A. ;
ter Braack, Esther M. ;
van Putten, Michel J. A. M. .
BRAIN TOPOGRAPHY, 2018, 31 (06) :917-930
[7]   Cortical surface-based analysis - II: Inflation, flattening, and a surface-based coordinate system [J].
Fischl, B ;
Sereno, MI ;
Dale, AM .
NEUROIMAGE, 1999, 9 (02) :195-207
[8]   Repetitive transcranial magnetic stimulation for obsessive-compulsive disorder: A systematic review and pairwise/network meta-analysis [J].
Fitzsimmons, Sophie M. D. D. ;
van der Werf, Ysbrand D. ;
van Campen, A. Dilene ;
Arns, Martijn ;
Sack, Alexander T. ;
Hoogendoorn, Adriaan W. ;
van den Heuvel, Odile A. .
JOURNAL OF AFFECTIVE DISORDERS, 2022, 302 :302-312
[9]   Fast computational optimization of TMS coil placement for individualized electric field targeting [J].
Gomez, Luis J. ;
Dannhauer, Moritz ;
Peterchev, Angel, V .
NEUROIMAGE, 2021, 228
[10]   Conditions for numerically accurate TMS electric field simulation [J].
Gomez, Luis J. ;
Dannhauer, Moritz ;
Koponen, Lari M. ;
Peterchev, Angel V. .
BRAIN STIMULATION, 2020, 13 (01) :157-166