Task-based detectability in anatomical background in digital mammography, digital breast tomosynthesis and synthetic mammography

被引:2
作者
Monnin, P. [1 ,2 ]
Damet, J. [1 ,2 ]
Bosmans, H. [3 ,4 ]
Marshall, N. W. [3 ,4 ]
机构
[1] Lausanne Univ Hosp CHUV, Inst Radiat Phys IRA, Rue Grand Pre 1, CH-1007 Lausanne, Switzerland
[2] Univ Lausanne, Rue Grand Pre 1, CH-1007 Lausanne, Switzerland
[3] Univ Hosp Gasthuisberg, Dept Radiol, Herestr 49, B-3000 Leuven, Belgium
[4] Katholieke Univ Leuven, Med Imaging Res Ctr, Med Phys & Qual Assessment, B-3000 Leuven, Belgium
关键词
detectability; mammography; digital breast tomosynthesis; model observer; anatomical noise; CASCADED SYSTEMS-ANALYSIS; SUBJECTIVE IMAGE QUALITY; CONE-BEAM CT; OBSERVER PERFORMANCE; COMPREHENSIVE MODEL; NOISE; PART; 2D-MAMMOGRAPHY; OPTIMIZATION; VALIDATION;
D O I
10.1088/1361-6560/ad1766
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Determining the detectability of targets for the different imaging modalities in mammography in the presence of anatomical background noise is challenging. This work proposes a method to compare the image quality and detectability of targets in digital mammography (DM), digital breast tomosynthesis (DBT) and synthetic mammography. Approach. The low-frequency structured noise produced by a water phantom with acrylic spheres was used to simulate anatomical background noise for the different types of images. A method was developed to apply the non-prewhitening observer model with eye filter (NPWE) in these conditions. A homogeneous poly(methyl) methacrylate phantom with a 0.2 mm thick aluminium disc was used to calculate 2D in-plane modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta, and system detective quantum efficiency for 30, 50 and 70 mm thicknesses. The in-depth MTFs of DBT volumes were determined using a thin tungsten wire. The MTF, system NPS and anatomical NPS were used in the NPWE model to calculate the threshold gold thickness of the gold discs contained in the CDMAM phantom, which was taken as reference. Main results. The correspondence between the NPWE model and the CDMAM phantom (linear Pearson correlation 0.980) yielded a threshold detectability index that was used to determine the threshold diameter of spherical microcalcifications and masses. DBT imaging improved the detection of masses, which depended mostly on the reduction of anatomical background noise. Conversely, DM images yielded the best detection of microcalcification s. Significance. The method presented in this study was able to quantify image quality and object detectability for the different imaging modalities and levels of anatomical background noise.
引用
收藏
页数:25
相关论文
共 57 条
[31]   Performance evaluation of digital breast tomosynthesis systems: physical methods and experimental data [J].
Marshall, N. W. ;
Bosmans, H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (22)
[32]   A comparison between objective and subjective image quality measurements for a full field digital mammography system [J].
Marshall, N. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) :2441-2463
[33]   Measurements of system sharpness for two digital breast tomosynthesis systems [J].
Marshall, N. W. ;
Bosmans, H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22) :7629-7650
[34]   Image quality assessment in digital mammography: part I. Technical characterization of the systems [J].
Marshall, N. W. ;
Monnin, P. ;
Bosmans, H. ;
Bochud, F. O. ;
Verdun, F. R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) :4201-4220
[35]   Characterizing anatomical variability in breast CT images [J].
Metheany, Kathrine G. ;
Abbey, Craig K. ;
Packard, Nathan ;
Boone, John M. .
MEDICAL PHYSICS, 2008, 35 (10) :4685-4694
[36]   TRANSFER-FUNCTION ANALYSIS OF RADIOGRAPHIC IMAGING-SYSTEMS [J].
METZ, CE ;
DOI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (06) :1079-1106
[37]   In-plane image quality and NPWE detectability index in digital breast tomosynthesis [J].
Monnin, P. ;
Verdun, F. R. ;
Bosmans, H. ;
Marshall, N. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (09)
[38]   A comprehensive model for x-ray projection imaging system efficiency and image quality characterization in the presence of scattered radiation [J].
Monnin, P. ;
Verdun, F. R. ;
Bosmans, H. ;
Perez, S. Rodriguez ;
Marshall, N. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (14) :5691-5722
[39]   A comprehensive model for quantum noise characterization in digital mammography [J].
Monnin, P. ;
Bosmans, H. ;
Verdun, F. R. ;
Marshall, N. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (05) :2083-2108
[40]   Image quality assessment in digital mammography: part II. NPWE as a validated alternative for contrast detail analysis [J].
Monnin, P. ;
Marshall, N. W. ;
Bosmans, H. ;
Bochud, F. O. ;
Verdun, F. R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) :4221-4238