Dehumidification load ratio: influence mechanism on air conditioning and energy saving potential analysis for building cooling

被引:4
作者
Jin, Zhineng [1 ]
Zheng, Yanhong [1 ]
Huang, Dongsheng [1 ]
Zhang, Yin [2 ]
Lv, Siqiang [1 ]
Sun, Hongli [1 ,3 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Peoples R China
[2] Southwest Minzu Univ, Sch Architecture, Chengdu 610225, Peoples R China
[3] Sichuan Univ, State Key Lab Hydraul & Mt River Engn, Chengdu 610065, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Building cooling; Air-source heat pump; Dehumidification; Energy saving potential; Load ratio; SOURCE HEAT-PUMP; CHINA CURRENT STATUS; PERFORMANCE; SYSTEM; OPTIMIZATION; TEMPERATURE; SOLAR; POWER;
D O I
10.1016/j.scs.2023.104942
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The construction energy consumption (EC) makes up around 35% of the total energy used. Half of this energy is used for air-conditioning to cool spaces. The effectiveness of cooling relates to various factors, particularly the dynamic thermal performance of air-conditioners (AC) in different conditions. Studying heat pumps in diverse hot and humid climates, especially where dehumidification matters in summer AC, reveals efficiency. Examining the connection between coefficient of performance (COP) and heat removal aids in lowering building energy usage and improving cooling systems. To achieve this, a validated thermodynamic model of heat pumps and a specific transient building heat transfer model were combined. The study focused on three distinct hot and humid climate zones: Guangzhou, Wuhan, and Jiuquan. Simulations of heat pump performance were conducted throughout the year to analyze variations in COP, relative humidity (RH), and latent heat load (LHL).Key findings indicate that the COP of heat pumps is notably influenced by the practical amount of dehumidification required. A positive correlation (correlation coefficient: 0.52151) exists between COP and LHL, emphasizing the importance of addressing dehumidification needs. The research highlights that the COP remains consistently high when the heat pump manages between 45% to 80% of the LHL. Practically, these findings have crucial implications for heat pump applications and building EC reduction, particularly in regions with pronounced dehumidification requirements during the cooling season. By understanding the interplay between heat pump efficiency, humidity, and heat load, practitioners can optimize heat pump performance to achieve energy savings. This research provides a valuable reference for designing and implementing cooling systems in various hot and humid climates, facilitating energy-efficient practices and environmentally friendly building operations.
引用
收藏
页数:23
相关论文
共 50 条
[31]   Energy saving potential of liquid desiccant in evaporative-cooling-assisted 100% outdoor air system [J].
Kim, Min-Hwi ;
Park, Jun-Seok ;
Jeong, Jae-Weon .
ENERGY, 2013, 59 :726-736
[32]   Energy saving potential of an air treatment system for improved building indoor air quality in Singapore [J].
Cui, X. ;
Mohan, B. ;
Islam, M. R. ;
Chou, S. K. ;
Chua, K. J. .
LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 :283-288
[33]   Research on Central Air Conditioning Systems and an Intelligent Prediction Model of Building Energy Load [J].
Pan, Lin ;
Wang, Sheng ;
Wang, Jiying ;
Xiao, Min ;
Tan, Zhirong .
ENERGIES, 2022, 15 (24)
[34]   Modelling the cooling energy saving potential of facade greening in summer for a set of building typologies in mid-latitudes [J].
Hoffmann, Karin A. ;
Suklje, Tomaz ;
Kozamernik, Jana ;
Nehls, Thomas .
ENERGY AND BUILDINGS, 2021, 238
[35]   Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit [J].
Wang, Yang ;
Zhao, Fu-Yun ;
Kuckelkorn, Jens ;
Liu, Di ;
Liu, Li-Qun ;
Pan, Xiao-Chuan .
ENERGY, 2014, 64 :991-1001
[36]   Calculation on Energy Saving Potential of a New Dry-type Air-conditioning System [J].
Hu, Xiaowei ;
Zhang, Yufeng ;
Wei, Lili ;
Wu, Xinhui .
PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON COMPUTER AND INFORMATION APPLICATIONS (ICCIA 2012), 2012, :368-371
[37]   Analysis of the application effect of energy-saving retrofit with additional evaporative cooling condenser for outdoor units of VRF air conditioning systems [J].
Li, Tao ;
Zeng, Kaiwei ;
Xue, Shihai ;
Zhou, Chuanhui ;
Li, Guannan ;
Gao, Jiajia .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 178 :324-335
[38]   Influence from the location of air source heat pump or cooling tower for air conditioning load of high rise buildings [J].
Zhang, JT .
INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03) :82-86
[39]   Energy-Saving Potential of Extending Temperature Set-Points in a VRF Air-Conditioned Building [J].
Kim, Joowook ;
Song, Doosam ;
Kim, Suyeon ;
Park, Sohyun ;
Choi, Youngjin ;
Lim, Hyunwoo .
ENERGIES, 2020, 13 (09)
[40]   Analysis of energy-saving for ventilation and air-conditioning system of subway stations with platform screen doors [J].
Su, Ziyi ;
Li, Xiaofeng .
JOURNAL OF BUILDING ENGINEERING, 2022, 59