Finite element analysis of minimally invasive nail placement and traditional nail placement in the treatment of lumbar 1 vertebral compression fracture

被引:1
作者
Huang, Chunbo [1 ]
Zhang, Chunling [2 ,3 ]
Su, Feng [2 ]
Su, Liu [2 ]
Ma, Pengpeng [2 ]
Zong, Zhiguo [2 ]
Zhang, Xin [2 ]
Li, Wei [2 ]
Cai, Ming [2 ]
机构
[1] Hebei North Univ, Dept Orthopaed, Zhangjiakou, Peoples R China
[2] Hebei North Univ, Affiliated Hosp 1, Dept Orthoped, Zhangjiakou, Peoples R China
[3] Hebei North Univ, Affiliated Hosp 1, Dept Orthoped, 26 Changqing Rd, Zhangjiakou 075000, Hebei, Peoples R China
关键词
finite element analysis; pedicle screw fixation; thoracolumbar fractures; MANAGEMENT; SPINE; INSTRUMENTATION; FUSION;
D O I
10.1097/MD.0000000000034145
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Using the finite element analysis method to help us better understand the biomechanical changes of the spine after surgery and the changes in the stress distribution around the screw implantation area. The finite element model of L1 vertebral compression fracture was constructed by using a large number of finite element programs. On the fracture model, 2 kinds of internal fixation devices are set up, namely: the first type of 4 screws across the injured vertebra through the adjacent upper and lower vertebrae + transverse connector; the second type of 4 screws crosses the injured vertebra through the adjacent upper and lower vertebrae + non-transverse connector. To study the distribution of the maximum displacement and von Mises stress of the intramedullary pedicle screws and rods of the 2 types of internal fixation devices after implantation in the spine under certain loading conditions. In traditional open pedicle screw fixation, the maximum stress in the pedicle screw fixation system in the direction of 3D movement is higher than in percutaneous pedicle screw fixation. There is no significant difference in the Von Mises stress of the pedicle screw between the 2 procedures when the spine performs flexion-extension and lateral flexion activities. When the spine is rotating axially, the Von Mises stress of the pedicle screw in conventional open surgery is significantly less than that of the screw in percutaneous pedicle screw fixation. Traditional open internal fixation produces stress peaks of 891.7 MPa and 886.34 MPa at the transverse joint during axial rotation. Only when the spine is rotating in the axial direction, the maximum displacement of traditional open pedicle screw fixation is smaller than that of percutaneous pedicle screw fixation. There is no significant difference in the maximum displacement between the 2 procedures when the spine is moving in other directions. Traditional open pedicle screw fixation can strengthen the stability of the spine in the direction of axial rotation, and can also be greater to reduce the maximum stress of the pedicle screw axial rotation, so the clinical treatment of unstable fractures of the thoracolumbar spine instability is of great significance.
引用
收藏
页数:9
相关论文
共 44 条
  • [31] Finite element analysis of different surgical approaches in various occlusal loading locations for zygomatic implant placement for the treatment of atrophic maxillae
    Ishak, M. I.
    Kadir, M. R. Abdul
    Sulaiman, E.
    Abu Kasim, N. H.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (09) : 1077 - 1089
  • [32] Novel screw-cable integrated system(SCIS) for minimally invasive treatment of patella transverse fractures: a finite element analysis
    Songyang Liu
    Shen Liu
    Feng Gu
    Xing Wei
    Yonghui Liang
    Journal of Orthopaedic Surgery and Research, 18
  • [33] Novel screw-cable integrated system(SCIS) for minimally invasive treatment of patella transverse fractures: a finite element analysis
    Liu, Songyang
    Liu, Shen
    Gu, Feng
    Wei, Xing
    Liang, Yonghui
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [34] Biomechanical assessment and 3D finite element analysis of the treatment of tibial fractures using minimally invasive percutaneous plates
    Hu, Xin-Jia
    Wang, Hua
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (02) : 1692 - 1698
  • [35] Biomechanical Study of Minimally Invasive Nonfusion Surgery for Treatment of Disc Herniation Associated with Adjacent Segment Disease: A Finite Element Analysis
    Li, Kai-Hua
    Li, Zhi-Guo
    Xiong, Hui -Ling
    Liu, Xiao-Ning
    Ma, Xin-Long
    WORLD NEUROSURGERY, 2023, 179 : E305 - E313
  • [36] Screw placement through a higher medial portal provides better initial stability in arthroscopic ACL tibial avulsion fracture fixation: a finite element analysis
    Xiao, Yang
    Shi, Changhao
    Deng, Geyang
    Ding, Zichu
    Xu, Jinhuang
    Chen, Bin
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [37] The morphological mapping of lateral compression type 1 pelvic fracture and pelvic ring stability classification: a finite element analysis
    Bin-Fei Zhang
    Jun Wang
    Yu-Min Zhang
    Hui-Guang Cheng
    Qian-Yue Cheng
    Wen-Wen Cao
    Journal of Orthopaedic Surgery and Research, 16
  • [38] Biomechanical characteristic differences of two new types of intramedullary nail devices in the treatment of comminuted intertrochanteric fractures of femur: a comparative study based on finite element analysis
    Tang, Zhongjian
    Lv, Yongxiang
    Zhu, Zhexi
    Lu, Yafei
    Zhou, Haibin
    Zhang, Yazhong
    Liao, Yifeng
    Wang, Bin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [39] The morphological mapping of lateral compression type 1 pelvic fracture and pelvic ring stability classification: a finite element analysis
    Zhang, Bin-Fei
    Wang, Jun
    Zhang, Yu-Min
    Cheng, Hui-Guang
    Cheng, Qian-Yue
    Cao, Wen-Wen
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [40] Comparative finite element analysis of three implants fixing stable and unstable subtrochanteric femoral fractures: Proximal Femoral Nail Antirotation (PFNA), Proximal Femoral Locking Plate (PFLP), and Reverse Less Invasive Stabilization System (LISS)
    Wang, Jie
    Ma, Jian-Xiong
    Lu, Bin
    Bai, Hao-Hao
    Wang, Ying
    Ma, Xin-Long
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (01) : 95 - 101