Experimental and theoretical examination of the energy performance and CO2 emissions of room air conditioners utilizing natural refrigerant R290 as a substitute for R22

被引:10
作者
Shaik, Sharmas Vali [1 ]
Gorantla, Kirankumar [2 ]
Shaik, Saboor [3 ]
Afzal, Asif [4 ]
Rajhi, Ali A. [5 ]
Cuce, Erdem [6 ,7 ]
机构
[1] Srinivasa Ramanujan Inst Technol Autonomous, Dept Mech Engn, Ananthapuramu 515701, Andhra Pradesh, India
[2] Aditya Coll Engn, Dept Humanities & Basic Sci, Surampalem 533437, Andhra Pradesh, India
[3] Vellore Inst Technol, Sch Mech Engn, Vellore 632014, Tamil Nadu, India
[4] Chandigarh Univ, Univ Ctr Res & Dev, Dept Mech Engn, Gharuan Mohali, India
[5] King Khalid Univ, Coll Engn, Dept Mech Engn, POB 394, Abha 61413, Saudi Arabia
[6] Recep Tayyip Erdogan Univ, Fac Engn & Architecture, Low Zero Carbon Energy Technol Lab, Zihni Derin Campus, TR-53100 Rize, Turkiye
[7] Recep Tayyip Erdogan Univ, Fac Engn & Architecture, Dept Mech Engn, Zihni Derin Campus, TR-53100 Rize, Turkiye
关键词
Cooling capacity; CO2; emissions; Energy efficiency ratio; GWP; R22 alternative refrigerants; FRICTIONAL PRESSURE-DROP; CONDENSATION HEAT-TRANSFER; EXERGY ANALYSIS; ROTARY-COMPRESSOR; STARTUP CHARACTERISTICS; GENERAL CORRELATION; IN SUBSTITUTE; MIXTURE; SYSTEM; FLOW;
D O I
10.1007/s10973-022-11888-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
The purpose of this research is to analyze the performance of an air conditioner that uses natural refrigerant R290 both analytically and experimentally. The feasibility of R290 for R22 air conditioner is examined thoroughly. Since the alternatives used in R22 air conditioners possess high GWPs and they are controlled by the Kyoto Protocol. The Kyoto Protocol mainly indicates that the high GWP refrigerants used in refrigeration and air conditioning sectors are classified into one among the targeted greenhouse gases. Therefore, the present work focuses on ecofriendly-refrigerant R290 as a substitute to R22. In comparison to R22, R290 has no ODP and a very low GWP. An analytical study is conducted based on the actual VCR cycle. An experimental study was conducted on the R22 air conditioner with R290 at various outdoor conditions. Test results revealed that electrical energy consumption of air conditioner with R290 was 12.30% lower compared to R22 for the lower operating conditions and it was 11.40% lower compared to R22 for the higher operating conditions. Cooling capacity of R290 compared to R22 is lower in the range of 6.37-9.24% for the test conditions studied. For the operating circumstances studied, the energy efficiency ratio of R290 is higher than R22, ranging from 2.41 to 6.77%. Compressor discharge temperature of R290 is lower in the range of 8.67-15.32 ? for all the investigated conditions. When compared to R22, CO2 emissions from air conditioners operating with R290 are lower in the range from 13.10 to 14.18%. The study revealed that R290 is a viable option to replace R22 used in air conditioners in terms of performance and environmental aspects.
引用
收藏
页码:8223 / 8241
页数:19
相关论文
共 57 条
[1]   Thermodynamic performance of automobile air conditioners working with R430A as a drop-in substitute to R134a [J].
Abraham, J. D. Andrew Pon ;
Mohanraj, M. .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 136 (05) :2071-2086
[2]  
AHRI standard, 2015, PERFORMANCE RATING P
[3]   Soft computing based optimization of a novel solar heliostat integrated energy system using artificial neural networks [J].
Alirahmi, S. Mojtaba ;
Khoshnevisan, A. ;
Shirazi, P. ;
Ahmadi, P. ;
Kari, D. .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 50
[4]   A study on the use of propane (R-290) in vending machines as a substitute for R-134a to minimise the global warming potential [J].
Alkhaledi, Khaled A. ;
Means, Kenneth .
INTERNATIONAL JOURNAL OF GLOBAL WARMING, 2018, 14 (01) :131-141
[5]   Exergy analysis and experimental study of a vapor compression refrigeration cycle A technical note [J].
Anand, S. ;
Tyagi, S. K. .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2012, 110 (02) :961-971
[6]  
[Anonymous], 2017, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Chapter 14, Climatic Design Information, ASHRAE Handbook-Fundamentals
[7]  
[Anonymous], 2018, BITZER REFRIGERANT R
[8]  
[Anonymous], 1992, IS: 73. Paving bitumen specification, V2nd
[9]   Exergy analysis of a vapour compression refrigeration system with r-22, R-407C and R-410A [J].
Arora, Akhilesh ;
Arora, B. B. ;
Pathak, B. D. ;
Sachdev, H. L. .
INTERNATIONAL JOURNAL OF EXERGY, 2007, 4 (04) :441-454
[10]  
Arora C P., 2009, Refrigeration and Air Conditioning, VThird