Thermal performance of two evacuated tube solar collectors with flat heat pipes

被引:10
作者
Zhang, Dengke [1 ]
Diao, Yanhua [1 ]
Wang, Zeyu [2 ]
Pan, Yawen [1 ]
Sun, Mengda [1 ]
Wang, Xinran [1 ]
Du, Peiyuan [1 ]
Zhao, Yaohua [1 ,3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
[2] China Nucl Power Engn Co Ltd, Beijing 100089, Peoples R China
[3] Zibo Boienergy Sci & Technol Co Ltd, Shandong 255000, Peoples R China
关键词
Flat micro-heat pipe array; Multi-channel flat tube; Louver fin; Solar water collector; Evacuated tube collector; AIR HEATER; PLATE; SYSTEMS; DESIGN;
D O I
10.1016/j.applthermaleng.2024.122366
中图分类号
O414.1 [热力学];
学科分类号
摘要
To promote the transition to clean heating methods in rural areas and improve solar energy utilization efficiency, two new types of solar water collectors with evacuated tubes, namely finned and finless collectors, are constructed with multi-channel flat tubes and flat micro-heat pipe arrays, and comparison experiments are conducted. By integrating with multi-channel flat tubes, the micro-heat pipe arrays, which function as the central heat transfer component, are capable of attaining effective thermal transmission. The multi-channel flat tubes have a substantial surface area available for heat transfer with the thermal fluid, while the evacuated tubes exhibit superior thermal insulation performance. The structural discrepancy between the two collectors lies in the presence or absence of louvered fins attached to the flat heat pipes inside the evacuated tubes. The comparative analysis of the two collectors includes time constant, thermal resistance analysis, distribution of temperature, normalized temperature difference, pressure drop, and actual operation effect under different conditions. The average thermal efficiency of the finless collector (59.4 %) is lower than that of the finned collector (78.2 %) on a typical experimental day. Then, further investigations are conducted to explore the effects of heat transfer fluid volume flow rate and inlet temperature on the thermal performance of finned solar water collector. With the heat transfer fluid volume flow rate of 120 L/h and the inlet temperature at 15 C, the finned collector can achieve its maximum thermal efficiency of 86.4 %.
引用
收藏
页数:25
相关论文
共 44 条
[1]   Improving the performance of evacuated tube heat pipe collectors using oil and foamed metals [J].
Abd-Elhady, M. S. ;
Nasreldin, M. ;
Elsheikh, M. N. .
AIN SHAMS ENGINEERING JOURNAL, 2018, 9 (04) :2683-2689
[2]   Recent progress in solar water heaters and solar collectors: A comprehensive review [J].
Ahmed, Sumair Faisal ;
Khalid, Mohammad ;
Vaka, Mahesh ;
Walvekar, Rashmi ;
Numan, Arshid ;
Rasheed, Abdul Khaliq ;
Mubarak, Nabisab Mujawar .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 25
[3]   A review on applications and techniques of improving the performance of heat pipe-solar collector systems [J].
Alshukri, Mohammed J. ;
Hussein, Ahmed Kadhim ;
Eidan, Adel A. ;
Alsabery, Ammar, I .
SOLAR ENERGY, 2022, 236 :417-433
[4]   Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate [J].
Ayompe, L. M. ;
Duffy, A. ;
Mc Keever, M. ;
Conlon, M. ;
McCormack, S. J. .
ENERGY, 2011, 36 (05) :3370-3378
[5]   Thermal Performance Enhancement in Flat Plate Solar Collector Solar Water Heater: A Review [J].
Azha, Nurril Ikmal Shamsul ;
Hussin, Hilmi ;
Nasif, Mohammad Shakir ;
Hussain, Tanweer .
PROCESSES, 2020, 8 (07)
[6]   Selection of phase change material for solar thermal storage application: a comparative study [J].
Babar, Onkar A. ;
Arora, Vinkel K. ;
Nema, Prabhat K. .
JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2019, 41 (09)
[7]   Concentrating photovoltaic thermal (CPVT) collectors and systems: Theory, performance assessment and applications [J].
Daneshazarian, Reza ;
Cuce, Erdem ;
Cuce, Pinar Mert ;
Sher, Farooq .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 :473-492
[8]   Experimental investigation of convective heat transfer performance of TiN nanofluid charged U-pipe evacuated tube solar thermal collector [J].
Deshmukh, Kishor ;
Karmare, Suhas ;
Patil, Pradeep .
APPLIED THERMAL ENGINEERING, 2023, 225
[9]   Study on an ETC solar water heater using flat and wavy diffuse reflectors [J].
Dinesh, S. N. ;
Ravi, S. ;
Kumar, P. Manoj ;
Subbiah, Ram ;
Karthick, Alagar ;
Saravanakumar, P. T. ;
Pranav, R. Aravinth .
MATERIALS TODAY-PROCEEDINGS, 2021, 47 :5228-5232
[10]  
Du B, 2021, Sustain. Energy Technol. Assess., V44