Monitoring Variations in the Use of Automated Contouring Software

被引:2
作者
Nealon, Kelly A. [1 ,2 ]
Han, Eun Young [3 ]
Kry, Stephen F. [4 ]
Nguyen, Callistus [5 ]
Pham, Mary [5 ]
Reed, Valerie K. [6 ]
Rosenthal, David [6 ]
Simiele, Samantha [3 ]
Court, Laurence E. [3 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys Patient Care, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Radiat Phys Outreach, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys Res, Houston, TX USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
基金
英国惠康基金;
关键词
CLINICAL-EVALUATION; SEGMENTATION; ACCURACY;
D O I
10.1016/j.prro.2023.09.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Our purpose was to identify variations in the clinical use of automatically generated contours that could be attributed to software error, off -label use, or automation bias. Methods and Materials: For 500 head and neck patients who were contoured by an in-house automated contouring system, Dice similarity coefficient and added path length were calculated between the contours generated by the automated system and the final contours after editing for clinical use. Statistical process control was used and control charts were generated with control limits at 3 standard deviations. Contours that exceeded the thresholds were investigated to determine the cause. Moving mean control plots were then generated to identify dosimetrists who were editing less over time, which could be indicative of automation bias. Results: Major contouring edits were flagged for: 1.0% brain, 3.1% brain stem, 3.5% left cochlea, 2.9% right cochlea, 4.8% esophagus, 4.1% left eye, 4.0% right eye, 2.2% left lens, 4.9% right lens, 2.5% mandible, 11% left optic nerve, 6.1% right optic nerve, 3.8% left parotid, 5.9% right parotid, and 3.0% of spinal cord contours. Identified causes of editing included unexpected patient positioning, deviation from standard clinical practice, and disagreement between dosimetrist preference and automated contouring style. A statistically significant (P < .05) difference was identified between the contour editing practice of dosimetrists, with 1 dosimetrist editing more across all organs at risk. Eighteen percent (27/150) of moving mean control plots created for 5 dosimetrists indicated the amount of contour editing was decreasing over time, possibly corresponding to automation bias. Conclusions: The developed system was used to detect statistically significant edits caused by software error, unexpected clinical use, and automation bias. The increased ability to detect systematic errors that occur when editing automatically generated contours will improve the safety of the automatic treatment planning workflow. (c) 2023 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
引用
收藏
页码:e75 / e85
页数:11
相关论文
共 50 条
[31]   Use of License Duration for Segmenting Software Market [J].
Feng, Nan ;
Miao, Yi-yang .
PROCEEDINGS OF THE 6TH INTERNATIONAL ASIA CONFERENCE ON INDUSTRIAL ENGINEERING AND MANAGEMENT INNOVATION, VOL 2: INNOVATION AND PRACTICE OF INDUSTRIAL ENGINEERING AND MANAGMENT, 2016, :901-907
[32]   AI-powered Automated Landscape Monitoring at Global Scale [J].
Hannel, Mark ;
Glennie, Erin ;
McAndrew, Brendan ;
Brumby, Steven P. ;
Larson, Amy E. ;
Mathis, Mark ;
Kerins, Peter ;
Mazzariello, Joseph ;
Hansen, Megan ;
Ermi, Gracie .
APPLICATIONS OF MACHINE LEARNING 2023, 2023, 12675
[33]   MyoVision: software for automated high-content analysis of skeletal muscle immunohistochemistry [J].
Wen, Yuan ;
Murach, Kevin A. ;
Vechetti, Ivan J., Jr. ;
Fry, Christopher S. ;
Vickery, Chase ;
Peterson, Charlotte A. ;
McCarthy, John J. ;
Campbell, Kenneth S. .
JOURNAL OF APPLIED PHYSIOLOGY, 2018, 124 (01) :40-51
[34]   Automated Comparison of State-Based Software Models in Terms of Their Language and Structure [J].
Walkinshaw, Neil ;
Bogdanov, Kirill .
ACM TRANSACTIONS ON SOFTWARE ENGINEERING AND METHODOLOGY, 2013, 22 (02)
[35]   Development and Application of Automated Vocal Fold Tracking Software in a Rat Surgical Model [J].
Pennington-FitzGerald, William ;
Joshi, Abhinav ;
Honzel, Emily ;
Hernandez-Morato, Ignacio ;
Pitman, Michael J. ;
Moayedi, Yalda .
LARYNGOSCOPE, 2024, 134 (01) :340-346
[36]   Vessel Metrics: A software tool for automated analysis of vascular structure in confocal imaging [J].
Mcgarry, Sean D. ;
Adjekukor, Cynthia ;
Ahuja, Suchit ;
Greysson-Wong, Jasper ;
Vien, Idy ;
Rinker, Kristina D. ;
Childs, Sarah J. .
MICROVASCULAR RESEARCH, 2024, 151
[37]   Automated hand hygiene monitoring system validation: Importance evidence overlooked [J].
Hansen, Marco Bo ;
Wismath, Nina ;
Fritz, Evelyn ;
Heininger, Alexandra ;
Moore, Lori D. ;
DiGiorgio, Megan ;
Arbogast, James W. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2021, 49 (06) :855-856
[38]   A contactless automated dynamic monitoring method for organoid morphology on the time axis [J].
Deng, Xun ;
Hu, Lun ;
Jiang, Zekun ;
Liu, Lu ;
Hu, Peng-Wei .
2023 23RD IEEE INTERNATIONAL CONFERENCE ON DATA MINING WORKSHOPS, ICDMW 2023, 2023, :412-417
[39]   Clinical validation of RIA-G, an automated optic nerve head analysis software [J].
Singh, Digvijay ;
Gunasekaran, Srilathaa ;
Hada, Maya ;
Gogia, Varun .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (07) :1089-1094
[40]   TScratch: a novel and simple software tool for automated analysis of monolayer wound healing assays [J].
Gebaeck, Tobias ;
Schulz, Martin Michael Peter ;
Koumoutsakos, Petros ;
Detmar, Michael .
BIOTECHNIQUES, 2009, 46 (04) :265-+