Monitoring Variations in the Use of Automated Contouring Software

被引:1
作者
Nealon, Kelly A. [1 ,2 ]
Han, Eun Young [3 ]
Kry, Stephen F. [4 ]
Nguyen, Callistus [5 ]
Pham, Mary [5 ]
Reed, Valerie K. [6 ]
Rosenthal, David [6 ]
Simiele, Samantha [3 ]
Court, Laurence E. [3 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys Patient Care, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Radiat Phys Outreach, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys Res, Houston, TX USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
基金
英国惠康基金;
关键词
CLINICAL-EVALUATION; SEGMENTATION; ACCURACY;
D O I
10.1016/j.prro.2023.09.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Our purpose was to identify variations in the clinical use of automatically generated contours that could be attributed to software error, off -label use, or automation bias. Methods and Materials: For 500 head and neck patients who were contoured by an in-house automated contouring system, Dice similarity coefficient and added path length were calculated between the contours generated by the automated system and the final contours after editing for clinical use. Statistical process control was used and control charts were generated with control limits at 3 standard deviations. Contours that exceeded the thresholds were investigated to determine the cause. Moving mean control plots were then generated to identify dosimetrists who were editing less over time, which could be indicative of automation bias. Results: Major contouring edits were flagged for: 1.0% brain, 3.1% brain stem, 3.5% left cochlea, 2.9% right cochlea, 4.8% esophagus, 4.1% left eye, 4.0% right eye, 2.2% left lens, 4.9% right lens, 2.5% mandible, 11% left optic nerve, 6.1% right optic nerve, 3.8% left parotid, 5.9% right parotid, and 3.0% of spinal cord contours. Identified causes of editing included unexpected patient positioning, deviation from standard clinical practice, and disagreement between dosimetrist preference and automated contouring style. A statistically significant (P < .05) difference was identified between the contour editing practice of dosimetrists, with 1 dosimetrist editing more across all organs at risk. Eighteen percent (27/150) of moving mean control plots created for 5 dosimetrists indicated the amount of contour editing was decreasing over time, possibly corresponding to automation bias. Conclusions: The developed system was used to detect statistically significant edits caused by software error, unexpected clinical use, and automation bias. The increased ability to detect systematic errors that occur when editing automatically generated contours will improve the safety of the automatic treatment planning workflow. (c) 2023 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
引用
收藏
页码:e75 / e85
页数:11
相关论文
共 50 条
  • [21] Automated robotic monitoring and inspection of steel structures and bridges
    Hung Manh La
    Tran Hiep Dinh
    Nhan Huu Pham
    Quang Phuc Ha
    Anh Quyen Pham
    ROBOTICA, 2019, 37 (05) : 947 - 967
  • [22] Developing an Automated Monitoring System for Cable Yarding Systems
    Gallo, Raimondo
    Visser, Rien
    Mazzetto, Fabrizio
    CROATIAN JOURNAL OF FOREST ENGINEERING, 2021, 42 (02) : 213 - 225
  • [23] False-response monitoring during automated perimetry
    Vingrys, AJ
    Demirel, S
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (07) : 513 - 517
  • [24] Renal cortical volume measured using automatic contouring software for computed tomography and its relationship with BMI, age and renal function
    Muto, Natalia Sayuri
    Kamishima, Tamotsu
    Harris, Ardene A.
    Kato, Fumi
    Onodera, Yuya
    Terae, Satoshi
    Shirato, Hiroki
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (01) : 151 - 156
  • [25] Stratified assessment of an FDA-cleared deep learning algorithm for automated detection and contouring of metastatic brain tumors in stereotactic radiosurgery
    Wang, Jen-Yeu
    Qu, Vera
    Hui, Caressa
    Sandhu, Navjot
    Mendoza, Maria G. G.
    Panjwani, Neil
    Chang, Yu-Cheng
    Liang, Chih-Hung
    Lu, Jen-Tang
    Wang, Lei
    Kovalchuk, Nataliya
    Gensheimer, Michael F. F.
    Soltys, Scott G. G.
    Pollom, Erqi L. L.
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [26] Validation of a Fully Automated Hybrid Deep Learning Cardiac Substructure Segmentation Tool for Contouring and Dose Evaluation in Lung Cancer Radiotherapy
    Chin, V.
    Finnegan, R. N.
    Chlapy, P.
    Otton, J.
    Haidar, A.
    Holloway, L.
    Thwaites, D. I.
    Dowling, J.
    Delaney, G. P.
    Vinod, S. K.
    CLINICAL ONCOLOGY, 2023, 35 (06) : 370 - 381
  • [27] AI-powered Automated Landscape Monitoring at Global Scale
    Hannel, Mark
    Glennie, Erin
    McAndrew, Brendan
    Brumby, Steven P.
    Larson, Amy E.
    Mathis, Mark
    Kerins, Peter
    Mazzariello, Joseph
    Hansen, Megan
    Ermi, Gracie
    APPLICATIONS OF MACHINE LEARNING 2023, 2023, 12675
  • [28] Use of License Duration for Segmenting Software Market
    Feng, Nan
    Miao, Yi-yang
    PROCEEDINGS OF THE 6TH INTERNATIONAL ASIA CONFERENCE ON INDUSTRIAL ENGINEERING AND MANAGEMENT INNOVATION, VOL 2: INNOVATION AND PRACTICE OF INDUSTRIAL ENGINEERING AND MANAGMENT, 2016, : 901 - 907
  • [29] Automated Comparison of State-Based Software Models in Terms of Their Language and Structure
    Walkinshaw, Neil
    Bogdanov, Kirill
    ACM TRANSACTIONS ON SOFTWARE ENGINEERING AND METHODOLOGY, 2013, 22 (02)
  • [30] Development and Application of Automated Vocal Fold Tracking Software in a Rat Surgical Model
    Pennington-FitzGerald, William
    Joshi, Abhinav
    Honzel, Emily
    Hernandez-Morato, Ignacio
    Pitman, Michael J.
    Moayedi, Yalda
    LARYNGOSCOPE, 2024, 134 (01) : 340 - 346