Monitoring Variations in the Use of Automated Contouring Software

被引:1
|
作者
Nealon, Kelly A. [1 ,2 ]
Han, Eun Young [3 ]
Kry, Stephen F. [4 ]
Nguyen, Callistus [5 ]
Pham, Mary [5 ]
Reed, Valerie K. [6 ]
Rosenthal, David [6 ]
Simiele, Samantha [3 ]
Court, Laurence E. [3 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys Patient Care, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Radiat Phys Outreach, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys Res, Houston, TX USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
基金
英国惠康基金;
关键词
CLINICAL-EVALUATION; SEGMENTATION; ACCURACY;
D O I
10.1016/j.prro.2023.09.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Our purpose was to identify variations in the clinical use of automatically generated contours that could be attributed to software error, off -label use, or automation bias. Methods and Materials: For 500 head and neck patients who were contoured by an in-house automated contouring system, Dice similarity coefficient and added path length were calculated between the contours generated by the automated system and the final contours after editing for clinical use. Statistical process control was used and control charts were generated with control limits at 3 standard deviations. Contours that exceeded the thresholds were investigated to determine the cause. Moving mean control plots were then generated to identify dosimetrists who were editing less over time, which could be indicative of automation bias. Results: Major contouring edits were flagged for: 1.0% brain, 3.1% brain stem, 3.5% left cochlea, 2.9% right cochlea, 4.8% esophagus, 4.1% left eye, 4.0% right eye, 2.2% left lens, 4.9% right lens, 2.5% mandible, 11% left optic nerve, 6.1% right optic nerve, 3.8% left parotid, 5.9% right parotid, and 3.0% of spinal cord contours. Identified causes of editing included unexpected patient positioning, deviation from standard clinical practice, and disagreement between dosimetrist preference and automated contouring style. A statistically significant (P < .05) difference was identified between the contour editing practice of dosimetrists, with 1 dosimetrist editing more across all organs at risk. Eighteen percent (27/150) of moving mean control plots created for 5 dosimetrists indicated the amount of contour editing was decreasing over time, possibly corresponding to automation bias. Conclusions: The developed system was used to detect statistically significant edits caused by software error, unexpected clinical use, and automation bias. The increased ability to detect systematic errors that occur when editing automatically generated contours will improve the safety of the automatic treatment planning workflow. (c) 2023 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
引用
收藏
页码:e75 / e85
页数:11
相关论文
共 50 条
  • [1] Deep Learning for Automated Contouring of Gross Tumor Volumes in Esophageal Cancer
    Jin, Linzhi
    Chen, Qi
    Shi, Aiwei
    Wang, Xiaomin
    Ren, Runchuan
    Zheng, Anping
    Song, Ping
    Zhang, Yaowen
    Wang, Nan
    Wang, Chenyu
    Wang, Nengchao
    Cheng, Xinyu
    Wang, Shaobin
    Ge, Hong
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [2] Automated measurement of fracture callus in radiographs using portable software
    Porter, Stephen M.
    Dailey, Hannah L.
    Hollar, Katherine A.
    Klein, Karina
    Harty, James A.
    Lujan, Trevor J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2016, 34 (07) : 1224 - 1233
  • [3] Deep Learning for Automated Contouring of Primary Tumor Volumes by MRI for Nasopharyngeal Carcinoma
    Lin, Li
    Dou, Qi
    Jin, Yue-Ming
    Zhou, Guan-Qun
    Tang, Yi-Qiang
    Chen, Wei-Lin
    Su, Bao-An
    Liu, Feng
    Tao, Chang-Juan
    Jiang, Ning
    Li, Jun-Yun
    Tang, Ling-Long
    Xie, Chuan-Miao
    Huang, Shao-Min
    Ma, Jun
    Heng, Pheng-Ann
    Wee, Joseph T. S.
    Chua, Melvin L. K.
    Chen, Hao
    Sun, Ying
    RADIOLOGY, 2019, 291 (03) : 677 - 686
  • [4] Automated contouring and statistical process control for plan quality in a breast clinical trial
    Baroudi, Hana
    Nguyen, Callistus I. Huy Minh
    Maroongroge, Sean
    Smith, Benjamin D.
    Niedzielski, Joshua S.
    Shaitelman, Simona F.
    Melancon, Adam
    Shete, Sanjay
    Whitaker, Thomas J.
    Mitchell, Melissa P.
    Arzu, Isidora Yvonne
    Duryea, Jack
    Hernandez, Soleil
    El Basha, Daniel
    Mumme, Raymond
    Netherton, Tucker
    Hoffman, Karen
    Court, Laurence
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
  • [5] Methodological approach to create an atlas using a commercial auto-contouring software
    Casati, Marta
    Piffer, Stefano
    Calusi, Silvia
    Marrazzo, Livia
    Simontacchi, Gabriele
    Di Cataldo, Vanessa
    Greto, Daniela
    Desideri, Isacco
    Vernaleone, Marco
    Francolini, Giulio
    Livi, Lorenzo
    Pallotta, Stefania
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 219 - 230
  • [6] Automated contouring and planning pipeline for hippocampal-avoidant whole-brain radiotherapy
    Feng, Christine H.
    Cornell, Mariel
    Moore, Kevin L.
    Karunamuni, Roshan
    Seibert, Tyler M.
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [7] Clinical assessment of a novel machine-learning automated contouring tool for radiotherapy planning
    Hu, Yunfei
    Nguyen, Huong
    Smith, Claire
    Chen, Tom
    Byrne, Mikel
    Archibald-Heeren, Ben
    Rijken, James
    Aland, Trent
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (07):
  • [8] PET Lesion Segmentation Using Automated Iso-intensity Contouring in Head and Neck Cancer
    Simon, Edmund
    Fox, Timothy H.
    Lee, Daniel
    Waller, Anthony F.
    Pantalone, Paul
    Jani, Ashesh B.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (04) : 249 - 255
  • [9] Clinical evaluation of the efficacy of limbus artificial intelligence software to augment contouring for prostate and nodes radiotherapy
    Starke, Alison
    Poxon, Jacqueline
    Patel, Kishen
    Wells, Paula
    Morris, Max
    Rudd, Pandora
    Tipples, Karen
    MacDougall, Niall
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1158) : 1125 - 1131
  • [10] Portable Ultrasound Research System for Use in Automated Bladder Monitoring with Machine-Learning-Based Segmentation
    Fournelle, Marc
    Gruen, Tobias
    Speicher, Daniel
    Weber, Steffen
    Yilmaz, Mehmet
    Schoeb, Dominik
    Miernik, Arkadiusz
    Reis, Gerd
    Tretbar, Steffen
    Hewener, Holger
    SENSORS, 2021, 21 (19)