Optimal fractionation and timing of weekly cone-beam CT in daily surface-guided radiotherapy for breast cancer

被引:2
|
作者
Peng, Haiyan [1 ]
Yang, Han [1 ]
Lei, Jinyan [1 ]
Dai, Xinyao [1 ]
Cao, Panpan [1 ]
Jin, Fu [1 ]
Luo, Huanli [1 ]
机构
[1] Chongqing Univ, Canc Hosp, Dept Radiat Oncol, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Postmastectomy radiotherapy; Multiple "SGRT plus CBCT" modes; Patient-specific parameters; Setup error; Dose distribution; RADIATION-THERAPY; PATIENT SETUP; SYSTEMS; MOTION; ERRORS;
D O I
10.1186/s13014-023-02279-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeSurface-guided radiotherapy (SGRT) has been demonstrated to be a promising supplement to cone-beam computed tomography (CBCT) in adjuvant breast cancer radiotherapy, but a rational combination mode is lacking in clinical practice. The aim of this study was to explore this mode and investigate its impact on the setup and dose accuracy.Methods and materialsDaily SGRT and weekly CBCT images were acquired for 23 patients with breast cancer who received conventional fractionated radiotherapy after lumpectomy. Sixteen modes were acquired by randomly selecting one (CBCT1), two (CBCTij), three (CBCTijk), four (CBCTijkl), and five (CBCT12345) images from the CBCT images for fusion with the SGRT. The CTV-PTV margins, OAR doses, and dose coverage (V95%) of PTV and CTV was calculated based on SGRT setup errors with different regions of interest (ROIs). Dose correlations between these modalities were investigated using Pearson and Spearman's methods. Patient-specific parameters were recorded to assess their impact on dose.ResultsThe CTV-PTV margins decreased with increasing CBCT frequencies and were close to 5 mm for CBCTijkl and CBCT12345. For the ipsilateral breast ROI, SGRT errors were larger in the AP direction, and target doses were higher in all modes than in the whole breast ROI (P < 0.05). In the ipsilateral ROI, the target dose correlations between all modes increased with increasing CBCT time intervals, decreased, and then increased with increasing CBCT frequencies, with the inflection point being CBCT participation at week 5. The dose deviations in CBCT123, CBCT124, CBCT125, CBCTijkl, and CBCT12345 were minimal and did not differ significantly (P > 0.05). There was excellent agreement between CBCT124 and CBCT1234, and between (CBCTijkl, CBCT12345) and CBCT125 in determining the classification for the percentage of PTV deviation (Kappa = 0.704-0.901). In addition, there were weak correlations between the patient's D-ips_b (ipsilateral breast diameter with bolus) and CTV doses in modes with CBCT participation at week 4 (R = 0.270 to 0.480).ConclusionsBased on weekly CBCT, these modes with ipsilateral ROI and a combination of daily SGRT and a CBCT frequency of & GE; 3 were recommended, and CBCT was required at weeks 1 and 2 for CBCTijk.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Cone-beam computed tomography-guided online adaptive radiotherapy is feasible for prostate cancer patients
    Zwart, Lisanne G. M.
    Ong, Francisca
    Asbroek, Liselotte A. ten
    van Dieren, Erik B.
    Koch, Siete A.
    Bhawanie, Anand
    de Wit, Elisabeth
    Dasselaar, Judith J.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 98 - 103
  • [22] USE OF CONE-BEAM COMPUTED TOMOGRAPHY TO CHARACTERIZE DAILY URINARY BLADDER VARIATIONS DURING FRACTIONATED RADIOTHERAPY FOR CANINE BLADDER CANCER
    Nieset, Jessica R.
    Harmon, Joseph F.
    LaRue, Susan M.
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (05) : 580 - 588
  • [23] Skin marker combined with surface-guided auto-positioning for breast DIBH radiotherapy daily initial patient setup: An optimal schedule for both accuracy and efficiency
    Lai, Jianjun
    Luo, Zhizeng
    Jiang, Lu
    Hu, Haili
    Gao, Chang
    Zhang, Chuanfeng
    Chen, Liting
    Wu, Jing
    Wu, Zhibing
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):
  • [24] Weekly kilovoltage cone-beam computed tomography for detection of dose discrepancies during (chemo)radiotherapy for head and neck cancer
    Hermans, Bregtje C. M.
    Persoon, Lucas C. G. G.
    Podesta, Mark
    Hoebers, Frank J. P.
    Verhaegen, Frank
    Troost, Esther G. C.
    ACTA ONCOLOGICA, 2015, 54 (09) : 1483 - 1489
  • [25] Reproducibility of chestwall and heart position using surface-guided versus RPM-guided DIBH radiotherapy for left breast cancer
    Lu, Wei
    Li, Guang
    Hong, Linda
    Yorke, Ellen
    Tang, Xiaoli
    Mechalakos, James G.
    Zhang, Pengpeng
    Cervino, Laura, I
    Powell, Simon
    Berry, Sean L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):
  • [26] Ultrasound versus Cone-beam CT image-guided radiotherapy for prostate and post-prostatectomy pretreatment localization
    Fargier-Voiron, Marie
    Presles, Benoit
    Pommier, Pascal
    Munoz, Alexandre
    Rit, Simon
    Sarrut, David
    Biston, Marie-Claude
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 997 - 1004
  • [27] UroLift implants as surrogate fiducial markers for cone-beam CT-based prostate image-guided radiotherapy
    Al-Balushi, Ahmed
    Cain, Michelle
    Reynolds, Phil
    Bridge, Pete
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [28] Cone-Beam Computed Tomography-Guided Online Adaptive Radiotherapy: Promising Results for Bladder Cancer Case
    Azzarouali, Sana
    Goudschaal, Karin
    Visser, Jorrit
    Bel, Arjan
    Daniels, Laurien
    den Boer, Duncan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [29] Optimal gantry angles and field sizes in kilovoltage cone-beam tomosynthesis for set-up of women with breast cancer undergoing radiotherapy treatment
    Lyatskaya, Yulia
    Buehler, Andreas
    Ng, Sook-Kien
    Wong, Julia
    Bellon, Jennifer R.
    Zygmanski, Piotr
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (03) : 633 - 638
  • [30] A study of the dosimetric impact of daily setup variations measured with cone-beam CT on three-dimensional conformal radiotherapy for early-stage breast cancer delivered in the prone position
    Xiao, Annie
    Jutzy, Jessica
    Hubert, Greg
    Edens, Meghan
    Washington, Maxine
    Hasan, Yasmin
    Chmura, Steven J.
    Al-Hallaq, Hania A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 146 - 154