Low-energy protons shallow spread-out Bragg peak imaging with a lithium fluoride crystal

被引:0
作者
Nichelatti, E. [1 ]
Piccinini, M. [2 ]
Ronsivalle, C. [2 ]
Ampollini, A. [2 ]
Picardi, L. [2 ]
Astorino, M. D. [2 ]
Nenzi, P. [2 ]
Montereali, R. M. [2 ]
机构
[1] ENEA CR Casaccia, Fus & Technol Safety & Secur Dept, Via Anguillarese 301, I-00123 Rome, Italy
[2] ENEA CR Frascati, Fus & Technol Safety & Secur Dept, Via E Fermi 45, I-00044 Frascati, Rome, Italy
关键词
Lithium fluoride; Color centers; Luminescence; Proton beam; Spread-out Bragg peak; ANALYTICAL APPROXIMATION; CENTERS; DETECTOR; THERAPY; F-2;
D O I
10.1016/j.nimb.2023.04.012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The 35 MeV proton beam produced by a modular linear accelerator was used to irradiate at grazing incidence a LiF crystal through a spinning Mylar multi-sector range modulation wheel and a Pyrex range shifter. Starting from a measured pristine depth dose curve, these energy-modulation devices were designed to plan a test shallow spread-out Bragg peak in water. The irradiation of the LiF crystal produced in its lattice a volume distribution of color centers, which could be visualized in a fluorescence microscope as a fluorescent image under blue-light illumination. Since the intensity of this fluorescent image was proportional point-by-point to the absorbed en-ergy, it was elaborated to obtain an experimental depth dose curve in the LiF crystal, from which the proton beam energy distribution was estimated. This latter was finally used to evaluate the corresponding spread-out Bragg peak that would be obtained in water and compare it to the designed one.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 35 条
[1]   Radiochromic EBT2 film dosimetry for low-energy protontherapy [J].
Angellier, G. ;
Gautier, M. ;
Herault, J. .
MEDICAL PHYSICS, 2011, 38 (11) :6171-6177
[2]  
[Anonymous], IMAGEJ V 1 47
[3]  
[Anonymous], 2010, MATHWORKS MATLAB V 7
[4]   Lithium fluoride as a novel X-ray image detector for biological μ-world capture [J].
Baldacchini, G ;
Bonfigli, F ;
Faenov, A ;
Flora, F ;
Montereali, RM ;
Pace, A ;
Pikuz, T ;
Reale, L .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2003, 3 (06) :483-486
[5]   High-contrast photoluminescent patterns in lithium fluoride crystals produced by soft x-rays from a laser-plasma source [J].
Baldacchini, G ;
Bonfigli, F ;
Flora, F ;
Montereali, RM ;
Murra, D ;
Nichelatti, E ;
Faenov, A ;
Pikuz, T .
APPLIED PHYSICS LETTERS, 2002, 80 (25) :4810-4812
[6]   Optical bands of F2 and F3+ centers in LiF [J].
Baldacchini, G ;
De Nicola, E ;
Montereali, RM ;
Scacco, A ;
Kalinov, V .
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 2000, 61 (01) :21-26
[7]   Dose distribution at the Bragg peak: Dose measurements using EBT and RTQA gafchromic film set at two positions to the central beam axis [J].
Borowicz, Dorota Maria ;
Malicki, Julian ;
Mytsin, Gennady ;
Shipulin, Konstantin .
MEDICAL PHYSICS, 2017, 44 (04) :1538-1544
[8]   An analytical approximation of the Bragg curve for therapeutic proton beams [J].
Bortfeld, T .
MEDICAL PHYSICS, 1997, 24 (12) :2024-2033
[9]   Absolute dose calibration of EBT3 Gafchromic films [J].
Campajola, L. ;
Casolaro, P. ;
Di Capua, F. .
JOURNAL OF INSTRUMENTATION, 2017, 12
[10]   The physics of radiochromic process: one calibration equation for all film types [J].
Casolaro, P. ;
Campajola, L. ;
Di Capua, F. .
JOURNAL OF INSTRUMENTATION, 2019, 14 (08)