Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout

被引:6
作者
Seo, Minjee [1 ,2 ]
Park, Haewook [1 ,2 ]
Lee, Seungeun [1 ,2 ]
Ko, Guen Bae [3 ,4 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Biomed Sci, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Nucl Med, 103 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
[4] Brightonix Imaging Inc, 25 Yeonmujang 5Ga Gil, Seoul 04782, South Korea
基金
新加坡国家研究基金会;
关键词
depth-of-interaction (DOI); dual-ended signal readout; high-resolution; positron emission tomography (PET); silicon photomultiplier (SiPM); CRYSTAL ARRAY; DOI DETECTOR; PET DETECTOR; PERFORMANCE; SCANNER; DESIGN;
D O I
10.1002/mp.16355
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundSmall-animal positron emission tomography (PET) systems are widely used in molecular imaging research and drug development. There is also growing interest in organ-dedicated clinical PET systems. In these small-diameter PET systems, the measurement of the depth-of-interaction (DOI) of annihilation photons in scintillation crystals allows for the correction of parallax error in PET system, leading to an improvement on the spatial resolution uniformity. The DOI information is also useful for improving the timing resolution of PET system as it enables the correction of DOI-dependent time walk in the arrival time difference measurement of annihilation photon pairs. The dual-ended readout scheme is one of the most widely investigated DOI measurement methods, which collects visible photons using a pair of photosensors located at both ends of the scintillation crystal. Although the dual-ended readout allows for simple and accurate DOI estimation, it requires twice the number of photosensors compared to the single-ended readout scheme. PurposeTo effectively reduce the number of photosensors in a dual-ended readout scheme, we propose a novel PET detector configuration that employs 45 degrees tilted and sparsely arranged silicon photomultipliers (SiPMs). In this configuration, the angle between the scintillation crystal and SiPM is 45 degrees. Therefore, and thus, the diagonal of the scintillation crystal matches one of the lateral sides of the SiPM. Accordingly, it allows for the use of SiPM device larger than the scintillation crystal, thereby improving light collection efficiency with a higher fill factor and reducing SiPM quantity. In addition, all scintillation crystals can achieve more uniform performance than other dual-ended readout methods with a sparse SiPM arrangement because 50% of the scintillation crystal cross section is commonly in contact with the SiPM. MethodsTo demonstrate the feasibility of our proposed concept, we implemented a PET detector that employs a 4x${\rm{\;}} \times \;$4 LSO block with a single crystal dimension of 3.03 x 3.03 x 20 mm(3) and a 45 degrees tilted SiPM array. The 45 degrees tilted SiPM array consists of 2 x 3 SiPM elements at the top ("Top SiPM") and 3 x 2 SiPM elements at the bottom ("Bottom SiPM"). Each crystal element of the 4 x 4 LSO block is optically coupled with each quarter section of the Top SiPM and Bottom SiPM pair. To characterize the performance of the PET detector, the energy, DOI, and timing resolution were measured for all 16 crystals. The energy data was obtained by summing all the charges from the Top SiPMs and Bottom SiPMs, and the DOI resolution was measured by irradiating the side of the crystal block at five different depths (2, 6, 10, 14, and 18 mm). The timing was estimated by averaging the arrival time of the annihilation photons measured at the Top SiPMs and Bottom SiPMs (Method 1). The DOI-dependent time-walk effect was further corrected by using DOI information and statistical variations in the trigger times at the Top SiPMs and Bottom SiPMs (Method 2). ResultsThe average DOI resolution of the proposed PET detector was 2.5 mm, thereby resolving the DOI at five different depths, and the average energy resolution was 16% full width at half maximum (FWHM). When Methods 1 and 2 were applied, the coincidence timing resolutions were 448 and 411 ps FWHM, respectively. ConclusionsWe expect that our novel low-cost PET detector design with 45 degrees tilted SiPMs and a dual-ended readout scheme would be a suitable solution for constructing a high-resolution PET system with DOI encoding capability.
引用
收藏
页码:4112 / 4121
页数:10
相关论文
共 47 条
[1]   Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors [J].
Akamatsu, Go ;
Tashima, Hideaki ;
Iwao, Yuma ;
Wakizaka, Hidekatsu ;
Maeda, Takamasa ;
Mohammadi, Akram ;
Takyu, Sodai ;
Nitta, Munetaka ;
Nishikido, Fumihiko ;
Rutherford, Harley ;
Chacon, Andrew ;
Safavi-Naeini, Mitra ;
Yoshida, Eiji ;
Yamaya, Taiga .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09)
[2]   NINO: An ultrafast low-power front-end amplifier discriminator for the time-of-flight detector in the ALICE experiment [J].
Anghinolfi, F ;
Jarron, P ;
Krummenacher, F ;
Usenko, E ;
Williams, MCS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :1974-1978
[3]   Development of Dedicated Brain PET Imaging Devices: Recent Advances and Future Perspectives [J].
Catana, Ciprian .
JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (08) :1044-1052
[4]   Molecular imaging of small animals with dedicated PET tomographs [J].
Chatziioannou, AF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) :98-114
[5]  
Du JW, 2022, IEEE T RADIAT PLASMA, V6, P522, DOI [10.1109/TRPMS.2021.3096534, 10.1109/trpms.2021.3096534]
[6]   Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals [J].
Du, Junwei ;
Arino-Estrada, Gerard ;
Bai, Xiaowei ;
Cherry, Simon R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
[7]   Performance evaluation of a high resolution dedicated breast PET scanner [J].
Garcia Hernandez, Trinitat ;
Vicedo Gonzalez, Aurora ;
Ferrer Rebolleda, Jose ;
Sanchez Jurado, Raul ;
Rosello Ferrando, Joan ;
Brualla Gonzalez, Luis ;
Granero Cabanero, Domingo ;
Cozar Santiago, Maria del Puig .
MEDICAL PHYSICS, 2016, 43 (05) :2261-2272
[8]   Characterization of a high-resolution hybrid DOI detector for a dedicated breast PET/CT scanner [J].
Godinez, Felipe ;
Chaudhari, Abhijit J. ;
Yang, Yongfeng ;
Farrell, Richard ;
Badawi, Ramsey D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11) :3435-3449
[9]   Organ-Dedicated Molecular Imaging Systems [J].
Gonzalez, Antonio J. ;
Sanchez, Filomeno ;
Benlloch, Jose M. .
IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (05) :388-403
[10]  
Guo L, 2020, J INSTRUM, V15, DOI [10.1088/1748-0221/15/01/p01003, 10.1088/1748-0221/15/01/P01003]