DMEK graft: One size does not fit all

被引:15
作者
Parekh, Mohit [1 ]
Romano, Davide [2 ]
Wongvisavavit, Rintra [3 ,4 ]
Coco, Giulia [5 ]
Giannaccare, Giuseppe [6 ]
Ferrari, Stefano [7 ]
Rocha-de-Lossada, Carlos [8 ,9 ,10 ]
Levis, Hannah J. [11 ]
Semeraro, Francesco [2 ]
Calvo-de-Mora, Marina Rodriguez [8 ,9 ,12 ]
Scorcia, Vincenzo [6 ]
Romano, Vito [2 ]
机构
[1] Harvard Med Sch, Massachusetts Eye & Ear, Schepens Eye Res Inst, Dept Ophthalmol, Boston, MA 02115 USA
[2] Univ Brescia, Dept Med & Surg Specialties Radiol Sci & Publ Hlt, Eye Clin, Piazzale Spedali Civili 1, I-25125 Brescia, Italy
[3] UCL, Inst Ophthalmol, London, England
[4] Chulabhorn Royal Acad, HRH Princess Chulabhorn Coll Med Sci, Fac Med & Publ Hlth, Bangkok, Thailand
[5] Univ Roma Tor Vergata, Dept Clin Sci & Translat Med, Rome, Italy
[6] Magna Graecia Univ Catanzaro, Dept Ophthalmol, Catanzaro, Italy
[7] Fdn Banca Occhi Veneto, Int Ctr Ocular Physiopathol, Venice, Italy
[8] Vithas Virgen Mar Hosp, Dept Ophthalmol Qvis, Almeria, Spain
[9] Hosp Univ Virgen Las Nieves, Dept Ophthalmol, Granada, Spain
[10] Univ Seville, Area Oftalmol, Dept Cirugia, Seville, Spain
[11] Univ Liverpool, Inst Life Course & Med Sci, Dept Eye & Vision Sci, Liverpool, Merseyside, England
[12] Hosp Reg Univ, Ophthalmol Dept, Malaga, Spain
关键词
corneal transplant; descemetorhexis; DMEK; folding; graft size; large graft; small graft; MEMBRANE ENDOTHELIAL KERATOPLASTY; TISSUE-PREPARATION; SURVIVAL; TRANSPLANTATION; CELLS;
D O I
10.1111/aos.15202
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Descemet membrane endothelial keratoplasty (DMEK) is a popular procedure for the treatment of corneal endothelial diseases mainly targeting Fuchs endothelial corneal dystrophy (FECD) and pseudophakic bullous keratopathy (PBK). Although DMEK has multiple advantages, it is challenging in terms of graft preparation and delivery. One of the crucial factors of DMEK graft preparation is determining the size of the graft. Evaluating risks and benefits of transplanting larger or smaller grafts compared with the descemetorhexis performed following a standard DMEK procedure thus becomes important. Advanced techniques like pre-loaded DMEK requires pre-selection of graft diameter without physical examination of the eye making it more challenging. Therefore, recognizing the benefits of graft size and the number of transplanted endothelial cells becomes essential. Smaller DMEK grafts have been preferred and accepted for grafting. Larger diameter grafts have advantages but can be challenging due to higher detachment rates. We thus aim to review the challenges of preparing and delivering DMEK tissues with small or large diameter based on selected descemetorhexis area, discuss the outcomes based on different graft sizes, highlight related complications and suggest which cases may benefit from adopting smaller or larger graft size.
引用
收藏
页码:E14 / E25
页数:12
相关论文
共 63 条
[1]   Mini-Descemet Membrane Endothelial Keratoplasty for the Early Treatment of Acute Corneal Hydrops in Keratoconus [J].
Bachmann, Bjoern ;
Haendel, Alexander ;
Siebelmann, Sebastian ;
Matthaei, Mario ;
Cursiefen, Claus .
CORNEA, 2019, 38 (08) :1043-1048
[3]   Five-Year Graft Survival and Clinical Outcomes of 500 Consecutive Cases After Descemet Membrane Endothelial Keratoplasty [J].
Birbal, Renuka S. ;
Dhubhghaill, Sorcha Ni ;
Bourgonje, Vincent J. A. ;
Hanko, Jennifer ;
Ham, Lisanne ;
Jager, Martine J. ;
Bohringer, Stefan ;
Oellerich, Silke ;
Melles, Gerrit R. J. .
CORNEA, 2020, 39 (03) :290-297
[4]   Donor Tissue Preparation for Descemet Membrane Endothelial Keratoplasty: An Updated Review [J].
Birbal, Renuka S. ;
Sikder, Shameema ;
Lie, Jessica T. ;
Groeneveld-van Beek, Esther A. ;
Oellerich, Silke ;
Melles, Gerrit R. J. .
CORNEA, 2018, 37 (01) :128-135
[5]   Importance of Axial Length and Functional Corneal Endothelial Cells in Descemet Membrane Endothelial Keratoplasty [J].
Borroni, Davide ;
Ferronato, Melanie ;
Krumina, Zita ;
Parekh, Mohit .
CORNEA, 2017, 36 (12) :E35-E36
[6]   Clinical Outcomes of Preloaded Descemet Membrane Endothelial Keratoplasty Grafts With Endothelium Tri-Folded Inwards [J].
Busin, Massimo ;
Leon, Pia ;
D'Angelo, Sergio ;
Ruzza, Alessandro ;
Ferrari, Stefano ;
Ponzin, Diego ;
Parekh, Mohit .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 193 :106-113
[7]   Contact Lens-Assisted Pull-Through Technique for Delivery of Tri-Folded (Endothelium in) DMEK Grafts Minimizes Surgical Time and Cell Loss [J].
Busin, Massimo ;
Leon, Pia ;
Scorcia, Vincenzo ;
Ponzin, Diego .
OPHTHALMOLOGY, 2016, 123 (03) :476-483
[8]   Descemet Endothelial Thickness Comparison Trial A Randomized Trial Comparing Ultrathin Descemet Stripping Automated Endothelial Keratoplasty with Descemet Membrane Endothelial Keratoplasty [J].
Chamberlain, Winston ;
Lin, Charles C. ;
Austin, Ariana ;
Schubach, Nicholas ;
Clover, Jameson ;
McLeod, Stephen D. ;
Porco, Travis C. ;
Lietman, Thomas M. ;
Rose-Nussbaumer, Jennifer .
OPHTHALMOLOGY, 2019, 126 (01) :19-26
[9]   Novel Technique for Descemetorhexis Under Ophthalmic Viscosurgical Devices and Air [J].
Coco, Giulia ;
Pagano, Luca ;
Borgia, Alfredo ;
Kaye, Stephen B. ;
Romano, Vito .
CORNEA, 2021, 40 (09) :1215-1217
[10]   Standardized "No-Touch" Technique for Descemet Membrane Endothelial Keratoplasty [J].
Dapena, Isabel ;
Moutsouris, Kyros ;
Droutsas, Konstantinos ;
Ham, Lisanne ;
van Dijk, Korine ;
Melles, Gerrit R. J. .
ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (01) :88-94