Interfacial Electromigration for Analysis of Biofluid Lipids in Small Volumes

被引:3
|
作者
Edwards, Madison E. [1 ]
Freitas, Dallas P. [1 ]
Hirtzel, Erin A. [1 ]
White, Nicholas [1 ]
Wang, Hongying [2 ]
Davidson, Laurie A. [2 ]
Chapkin, Robert S. [2 ]
Sun, Yuxiang [2 ]
Yan, Xin [1 ]
机构
[1] Texas A&M Univ, Dept Chem, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Nutr, College Stn, TX 77845 USA
基金
美国国家科学基金会;
关键词
IONIZATION MASS-SPECTROMETRY; DOUBLE-BOND POSITION; INDUCED DISSOCIATION; ALZHEIMERS-DISEASE; NANO-ELECTROSPRAY; BIOMARKERS; ELUCIDATION; EPOXIDATION; EXTRACTION; PLATFORM;
D O I
10.1021/acs.analchem.3c04309
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lipids are important biomarkers within the field of disease diagnostics and can serve as indicators of disease progression and predictors of treatment effectiveness. Although lipids can provide important insight into how diseases initiate and progress, mass spectrometric methods for lipid characterization and profiling are limited due to lipid structural diversity, particularly the presence of various lipid isomers. Moreover, the difficulty of handling small-volume samples exacerbates the intricacies of biological analyses. In this work, we have developed a strategy that electromigrates a thin film of a small-volume biological sample directly to the air-liquid interface formed at the tip of a theta capillary. Importantly, we seamlessly integrated in situ biological lipid extraction with accelerated chemical derivatization, enabled by the air-liquid interface, and conducted isomeric structural characterization within a unified platform utilizing theta capillary nanoelectrospray ionization mass spectrometry, all tailored for small-volume sample analysis. We applied this unified platform to the analysis of lipids from small-volume human plasma and Alzheimer's disease mouse serum samples. Accelerated electro-epoxidation of unsaturated lipids at the interface allowed us to characterize lipid double-bond positional isomers. The unique application of electromigration of a thin film to the air-liquid interface in combination with accelerated interfacial reactions holds great potential in small-volume sample analysis for disease diagnosis and prevention.
引用
收藏
页码:18557 / 18563
页数:7
相关论文
共 50 条
  • [21] INTERFACIAL TENSION BETWEEN LIPIDS AND FIXATIVES
    JOHNSON, FB
    BRYANT, MJ
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1967, 15 (12) : 788 - &
  • [22] Effects of electromigration on interfacial reactions in cast Sn/Cu joints
    Chen S.-W.
    Wang C.-H.
    J Mater Res, 2007, 3 (695-702): : 695 - 702
  • [23] Effects of electromigration on interfacial reactions in cast Sn/Cu joints
    Chen, Sinn-Wen
    Wang, Chao-Hong
    JOURNAL OF MATERIALS RESEARCH, 2007, 22 (03) : 695 - 702
  • [24] Effect of interfacial condition on electromigration for narrow and wide copper interconnects
    Cheng, Yi-Lung
    Wang, Ying-Lang
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (05) : 2494 - 2499
  • [25] THE USE OF SEM FOR MULTIELEMENT ANALYSIS IN SMALL VOLUMES AND LOW CONCENTRATIONS
    BACHMANN, K
    STEIGERWALD, K
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (04): : 410 - 413
  • [26] SMALL VOLUMES QUANTIFIED
    MONNAT, RJ
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1979, 103 (11) : 602 - 602
  • [28] DIALYSIS OF SMALL VOLUMES
    ARIF, BM
    BIOTECHNIQUES, 1986, 4 (06) : 499 - 499
  • [29] BIOFLUID ANALYSIS OF HEMORRHAGIC SHOCK USING METABOLOMICS
    Lusczek, E.
    Lexcen, D.
    Witowski, N.
    Greenberg, J.
    Mulier, K.
    Chipman, J.
    Beilman, G.
    SHOCK, 2010, 33 : 47 - 47
  • [30] Microcuvette for-integration with infrared spectrometer for biofluid analysis
    Shenoy, G
    Srivastava, R
    Forrest, S
    Besser, RS
    McShane, MJ
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1665 - 1666