Rapid retrofit of substandard short RC columns with buckled longitudinal bars using CFRP jacketing

被引:1
作者
Moretti, Marina L. [1 ]
机构
[1] Natl Tech Univ Athens, Sch Architecture, GR-10682 Athens, Greece
关键词
axial compressive strength; buckling of longitudinal bars; damage level; retrofit with CFRP jacket; short reinforced concrete column; stiffness and ductility; REINFORCED-CONCRETE COLUMNS; SEISMIC PERFORMANCE; REPAIR; DAMAGE; BEHAVIOR; DESIGN; CARBON; POSTEARTHQUAKE; CONFINEMENT; BUILDINGS;
D O I
10.12989/eas.2023.24.2.097
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This experimental study investigates the effectiveness of applying carbon fiber reinforced polymer (CFRP) jackets for the retrofit of short reinforced concrete (RC) columns with inadequate transverse reinforcement and stirrup spacing to longitudinal rebar diameter equal to 12. RC columns scaled at 1/3, with round and square section, were subjected to axial compression up to failure. A damage scale is introduced for the assessment of the damage severity, which focusses on the extent of buckling of the longitudinal rebars. The damaged specimens were subsequently repaired with unidirectional CFRP jackets without any treatment of the buckled reinforcing bars and were finally re-tested to failure. Test results indicate that CFRP jackets may be effectively applied to rehabilitate RC columns (a) with inadequate transverse reinforcement constructed according to older practices so as to meet modern code requirements, and (b) with moderately buckled bars without the need of previously repairing the reinforcement bars, an application technique which may considerably facilitate the retrofit of earthquake damaged RC columns. Factors for the estimation of the reduced mechanical properties of the repaired specimens compared to the respective values for intact CFRP-jacketed specimens, in relation to the level of damage prior to retrofit, are proposed both for the compressive strength and the average modulus of elasticity. It was determined that the compressive strength of the retrofitted CFRP-jacketed columns is reduced by 90% to 65%, while the average modulus of elasticity is lower by 60% to 25% in respect to similar undamaged columns jacketed with the same layers of CFRP.
引用
收藏
页码:97 / 109
页数:13
相关论文
共 66 条
  • [1] Post-earthquake emergency assessment of building damage, safety and usability - Part 1: Technical issues
    Anagnostopoulos, S.
    Moretti, M.
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2008, 28 (03) : 223 - 232
  • [2] [Anonymous], 2005, Eurocode 8
  • [3] [Anonymous], 2004, EUROCODE 8
  • [4] [Anonymous], 2004, EUROCODE 2
  • [5] [Anonymous], 1983, CEB B
  • [6] [Anonymous], 1996, ATC-32
  • [7] [Anonymous], 1991, ATC20 GOV OFF EM SER
  • [8] Buckling of steel reinforcing bars in FRP-confined RC columns: An experimental study
    Bai, Yu-Lei
    Dai, Jian-Guo
    Teng, J. G.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 140 : 403 - 415
  • [9] Seismic Behavior of Repaired and Externally FRP-Jacketed Short Columns Built with Extremely Low-Strength Concrete
    Bedirhanoglu, Idris
    Ilki, Alper
    Triantafillou, Thanasis C.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2022, 26 (01)
  • [10] Bar Buckling in RC Columns Confined with Composite Materials
    Bournas, D. A.
    Triantafillou, T. C.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (03) : 393 - 403