Dynamic Ramping of Retrofitted Coal -Fired Power Plants: Basic Formulation and Tightened Approximation

被引:0
作者
Lei, Chao [1 ,2 ]
Bu, Siqi [1 ,2 ]
Wang, Qianggang [3 ]
Chen, Qifan [1 ,2 ]
机构
[1] Hong Kong Polytech Univ, Dept Elect Engn, Hong Kong, Peoples R China
[2] Ctr Adv Reliabil & Safety CAiRS, Hong Kong, Peoples R China
[3] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing, Peoples R China
来源
2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM | 2023年
基金
国家重点研发计划;
关键词
Dynamic ramping; retrofitted coal-fired units; ramping margin formulations; power system flexibility; MODEL;
D O I
10.1109/PESGM52003.2023.10253043
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Decarbonization initiatives play a major role in avoiding worldwide climate change effects. One of the effective actions is expected to upgrade existing aged coal-fired plants to retrofitted coal-fired plants by installing pollution reduction technology for emission reduction. Besides this merit, retrofitted coal-fired units can enable faster ramp rates and achieve lower minimal output power levels, which substantially relieves the peak regulation stress. In this paper, we focus on the dynamic ramp rate characteristics and then derive a new family of nonlinear ramping margin formulations of retrofitted coal-fired units. Moreover, we further tighten proposed nonlinear ramping margins to be a set of linear constraints with a minor inner approximation error. Results of case study validate the effectiveness of the proposed dynamic ramping margin formulation for retrofitted coal-fired power units.
引用
收藏
页数:6
相关论文
共 14 条
  • [1] Campbell Richard J, 2013, INCREASING EFFICIENC, P10
  • [2] Dynamic Ramping Model Including Intraperiod Ramp-Rate Changes in Unit Commitment
    Correa-Posada, Carlos M.
    Morales-Espana, German
    Duenas, Pablo
    Sanchez-Martin, Pedro
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2017, 8 (01) : 43 - 50
  • [3] Ess F., 2017, Tech. Rep. 115/04-S-2017/EN
  • [4] He G, 2020, NAT COMMUN, V11, DOI 10.1038/s41467-020-16184-x
  • [5] Challenges of renewable energy penetration on power system flexibility: A survey
    Impram, Semich
    Nese, Secil Varbak
    Oral, Bulent
    [J]. ENERGY STRATEGY REVIEWS, 2020, 31
  • [6] Data-Driven Look-Ahead Unit Commitment Considering Forbidden Zones and Dynamic Ramping Rates
    Jin, Ziliang
    Pan, Kai
    Fan, Lei
    Ding, Tao
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (06) : 3267 - 3276
  • [7] Lei C, 2023, IEEE Trans. Power Syst., P1
  • [8] Dynamic ramping in unit commitment
    Li, Tao
    Shahidehpour, Mohammad
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) : 1379 - 1381
  • [9] HOW CHINA COULD BE CARBON NEUTRAL BY MID-CENTURY
    Mallapaty, Smriti
    [J]. NATURE, 2020, 586 (7830) : 482 - 483
  • [10] Economic Decision-Making for Coal Power Flexibility Retrofitting and Compensation in China
    Na, Chunning
    Yuan, Jiahai
    Zhu, Yuhong
    Xue, Li