AN EXPERIMENTAL INVESTIGATION TO PREDICT OPTIMUM CHARGE OF A HEAT PUMP SYSTEM

被引:10
作者
Afshari, Faraz [1 ]
Khanlari, Ataollah [2 ]
Tuncer, Azim Dogus [3 ,4 ]
Soezen, Adnan [5 ]
机构
[1] Erzurum Tech Univ, Fac Engn, Dept Mech Engn, Erzurum, Turkiye
[2] Tarsus Univ, Fac Engn, Dept Mech Engn, Mersin, Turkiye
[3] Burdur Mehmet Akif Ersoy Univ, Fac Engn Architecture, Dept Energy Syst Engn, Burdur, Turkiye
[4] Gazi Univ, Inst Nat & Appl Sci, Ankara, Turkiye
[5] Gazi Univ, Fac Technol, Dept Energy Syst Engn, Ankara, Turkiye
关键词
heat pump; refrigerant; optimization; overcharge; undercharge; REFRIGERANT CHARGE; PERFORMANCE ANALYSIS; AIR-FLOW; WATER;
D O I
10.1615/HeatTransRes.2022044669
中图分类号
O414.1 [热力学];
学科分类号
摘要
Working principles of heat pumps is an important matter from a thermodynamic point of view that has been researched from various aspects. In this study, undercharged, optimum charged, and overcharged conditions of a heat pump were investigated using R134a refrigerant. Variations in temperature, pressure, and the coefficient of performance have been evaluated and it was aimed to find out the optimum charge condition considering different parameters. According to the experimentally obtained findings, the coefficient of performance was increased by more than three times when the refrigerant amount increased from 2000 g to similar to 7300 g. The general outcomes of the present study indicated that optimum refrigerant charge amount can notably affect the performance of heat pump apparatus. It was shown that the P-h diagram of all heat pump systems depends on the working conditions and the refrigerant charge is a very important criterion that can make significant changes in the P-h diagram. It was found that, by increasing refrigerant charge, after the downtrend starts in the compressor inlet temperature, 20% refrigerant can be added to achieve the maximum COP value. Additionally, the critical point in expansion valve outlet temperature was used to find the optimum charge. It was revealed that if 140% refrigerant is added to the given refrigerant at critical point, the optimum COP value can be achieved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 42 条
[1]   Heat transition in the European building sector: Overview of the heat decarbonisation practices through heat pump technology [J].
Abbasi, Mohammad Hosein ;
Abdullah, Badr ;
Ahmad, Muhammad Waseem ;
Rostami, Ali ;
Cullen, Jeff .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 48
[2]   Thermodynamic analysis of a system converted from heat pump to refrigeration device [J].
Afshari, Faraz ;
Karagoz, Sendogan ;
Comakli, Omer ;
Zavaragh, Hadi Ghasemi .
HEAT AND MASS TRANSFER, 2019, 55 (02) :281-291
[3]   Comparative performance analysis of a solar assisted heat pump for greenhouse heating in Tunisia [J].
Agrebi, Sameh ;
Chargui, Ridha ;
Tashtoush, Bourhan ;
Guizani, AmenAllah .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 :547-558
[4]   Evaluation of the impacts of high stage refrigerant charge on cascade heat pump performance [J].
Chae, Jung-Hoon ;
Choi, Jong Min .
RENEWABLE ENERGY, 2015, 79 :66-71
[5]   Effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump [J].
Cho, HY ;
Ryu, CG ;
Kim, YC ;
Kim, HY .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08) :1266-1273
[6]   Refrigerant amount detection algorithm for a ground source heat pump unit [J].
Choi, Hangseok ;
Cho, Honghyun ;
Choi, Jong Min .
RENEWABLE ENERGY, 2012, 42 :111-117
[7]   Influence of the expansion device on the performance of a heat pump using R407C under a range of charging conditions [J].
Choi, J ;
Kim, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04) :378-384
[8]   The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube [J].
Choi, JM ;
Kim, YC .
ENERGY, 2002, 27 (04) :391-404
[9]   Design and performance study of the ground-coupled heat pump system with an operating parameter [J].
Chung, Jin Taek ;
Choi, Jong Min .
RENEWABLE ENERGY, 2012, 42 :118-124
[10]   Performance analysis on the charging and discharging process of a household heat pump water heater [J].
Dai, Nannan ;
Li, Shuhong ;
Ye, Qiang .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 98 :266-273