Contrast-Enhanced Cardiac Magnetic Resonance Imaging With a Manganese-Based Alternative to Gadolinium for Tissue Characterization of Acute Myocardial Infarction

被引:15
作者
Bonner, Benjamin P. [1 ,2 ,4 ]
Yurista, Salva R. [1 ,2 ,3 ]
Coll-Font, Jaume [1 ,2 ,3 ]
Chen, Shi [1 ,2 ]
Eder, Robert A. [1 ,2 ]
Foster, Anna N. [1 ,2 ]
Nguyen, Khoi D. [1 ,2 ,3 ]
Caravan, Peter [2 ,3 ]
Gale, Eric M. [2 ,3 ]
Nguyen, Christopher [1 ,2 ,3 ,5 ,6 ,7 ]
机构
[1] Massachusetts Gen Hosp, Cardiovasc Res Ctr, Boston, MA USA
[2] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA USA
[3] Harvard Med Sch, Boston, MA USA
[4] Louisiana State Univ Hlth Sci Ctr, New Orleans, LA USA
[5] Harvard Massachusetts Inst Technol, Div Hlth Sci Technol, Cambridge, MA USA
[6] Cleveland Clin, Heart Vasc & Thorac Inst, Cardiovasc Innovat Res Ctr, Cleveland, OH USA
[7] Cleveland Clin, Heart Vasc & Thorac Inst, Cardiovasc Innovat Res Ctr, 9500 Euclid Ave,JJ50S, Cleveland, OH 44195 USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2023年 / 12卷 / 08期
基金
美国国家卫生研究院;
关键词
contrast agent; gadolinium; magnetic resonance imaging; manganese; myocardial infarction; VENTRICULAR EJECTION FRACTION; HYPERTROPHIC CARDIOMYOPATHY; DELAYED ENHANCEMENT; AMERICAN-COLLEGE; KIDNEY-DISEASE; SIZE; AGENT; RISK; BIODISTRIBUTION; DYSFUNCTION;
D O I
10.1161/JAHA.122.026923
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundLate gadolinium enhancement cardiac magnetic resonance imaging is an effective and reproducible method for characterizing myocardial infarction. However, gadolinium-based contrast agents are contraindicated in patients with acute and chronic renal insufficiency. In addition, several recent studies have noted tissue deposition of free gadolinium in patients who have undergone serial contrast-enhanced magnetic resonance imaging. There is a clinical need for alternative forms of magnetic resonance imaging contrast agents that are acceptable in the setting of renal insufficiency. Methods and ResultsThree days after 80 minutes of ischemia/reperfusion of the left anterior descending coronary artery, cardiac magnetic resonance imaging was performed to assess myocardial lesion burden using both contrast agents. Late gadolinium enhancement cardiac magnetic resonance imaging was examined 10 and 15 minutes after contrast injection. Contrast agents were administered in alternating manner with a 2- to 3-hour washout period between contrast agent injections. Lesion evaluation and image processing were performed using Segment Medviso software. Mean infarct size and transmurality, measured using RVP-001, were not different compared with those measured using late gadolinium enhancement images. Bland-Altman analysis demonstrated a nominal bias of 0.13 mL (<1% of average total lesion volume) for RVP-001 in terms of gross infarct size measurement. ConclusionsThe experimental manganese-based contrast agent RVP-001 appears to be an effective agent for assessment of myocardial infarction location, size, and transmurality, and it may be useful as an alternative to gadolinium-based agents.
引用
收藏
页数:10
相关论文
共 49 条
[1]   Higher New York Heart Association classes and increased mortality and hospitalization in patients with heart failure and preserved left ventricular function [J].
Ahmed, A ;
Aronow, WS ;
Fleg, JL .
AMERICAN HEART JOURNAL, 2006, 151 (02) :444-450
[2]   Biodistribution of Gadolinium-Based Contrast Agents, Including Gadolinium Deposition [J].
Aime, Silvio ;
Caravan, Peter .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (06) :1259-1267
[3]  
Albert NM, 2008, CRIT CARE NURSE, V28, P20
[4]   Delayed Hyper-Enhancement Magnetic Resonance Imaging Provides Incremental Diagnostic and Prognostic Utility in Suspected Cardiac Amyloidosis [J].
Austin, Bethany A. ;
Tang, W. H. Wilson ;
Rodriguez, E. Rene ;
Tan, Carmela ;
Flamm, Scott D. ;
Taylor, David O. ;
Starling, Randall C. ;
Desai, Milind Y. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (12) :1369-1377
[5]   Effect of contrast dose and field strength in the magnetic resonance detection of brain metastases [J].
Ba-Ssalamah, A ;
Nöbauer-Huhmann, IM ;
Pinker, K ;
Schibany, N ;
Prokesch, R ;
Mehrain, S ;
Mlynárik, V ;
Fog, A ;
Heimberger, K ;
Trattnig, S .
INVESTIGATIVE RADIOLOGY, 2003, 38 (07) :415-422
[6]   MR imaging probes: design and applications [J].
Boros, Eszter ;
Gale, Eric M. ;
Caravan, Peter .
DALTON TRANSACTIONS, 2015, 44 (11) :4804-4818
[7]   Manganese metabolism in humans [J].
Chen, Pan ;
Bornhorst, Julia ;
Aschner, Michael .
FRONTIERS IN BIOSCIENCE-LANDMARK, 2018, 23 :1655-1679
[8]   A new automatic algorithm for quantification of myocardial infarction imaged by late gadolinium enhancement cardiovascular magnetic resonance: experimental validation and comparison to expert delineations in multi-center, multi-vendor patient data [J].
Engblom, Henrik ;
Tufvesson, Jane ;
Jablonowski, Robert ;
Carlsson, Marcus ;
Aletras, Anthony H. ;
Hoffmann, Pavel ;
Jacquier, Alexis ;
Kober, Frank ;
Metzler, Bernhard ;
Erlinge, David ;
Atar, Dan ;
Arheden, Hakan ;
Heiberg, Einar .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
[9]   Tumor Contrast Enhancement and Whole-Body Elimination of the Manganese-Based Magnetic Resonance Imaging Contrast Agent Mn-PyC3A [J].
Erstad, Derek J. ;
Ramsay, Ian A. ;
Jordan, Veronica Clavijo ;
Sojoodi, Mozhdeh ;
Fuchs, Bryan C. ;
Tanabe, Kenneth K. ;
Caravan, Peter ;
Gale, Eric M. .
INVESTIGATIVE RADIOLOGY, 2019, 54 (11) :697-703
[10]   Cardiac imaging after myocardial infarction [J].
Flachskampf, Frank A. ;
Schmid, Michael ;
Rost, Christian ;
Achenbach, Stephan ;
DeMaria, Anthony N. ;
Daniel, Werner G. .
EUROPEAN HEART JOURNAL, 2011, 32 (03) :272-283