Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study

被引:9
作者
Kuusisto, Niina [1 ,2 ]
Abushahba, Faleh [3 ]
Syrjanen, Stina [1 ]
Huumonen, Sisko [4 ,5 ]
Vallittu, Pekka [6 ,7 ,8 ]
Narhi, Timo [3 ]
机构
[1] Univ Turku, Inst Dent, Dept Oral Pathol & Radiol, Turku, Finland
[2] Paijat Hame Cent Hosp, Dept Radiol, Lahti, Finland
[3] Univ Turku, Inst Dent, Dept Prosthet Dent & Stomatognath Physiol, Turku, Finland
[4] Univ Eastern Finland, Inst Dent, Kuopio, Finland
[5] Kuopio Univ Hosp, Diagnost Imaging Ctr, Kuopio, Finland
[6] Univ Turku, Inst Dent, Dept Biomat Sci, Turku, Finland
[7] Univ Turku, Inst Dent, Turku Clin Biomat Ctr TCBC, Turku, Finland
[8] Welf Div, City Of Turku, Finland
关键词
peri-implantitis; artifact; cone beam computed tomography; FIBER-REINFORCED COMPOSITE; DENTAL IMPLANTS; RADIOGRAPHY; DIAGNOSIS; ACCURACY;
D O I
10.1259/dmfr.20230252
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Three-dimensional cone beam computed tomography (CBCT) imaging can be considered, especially in patients with complicated peri-implantitis (PI). Artifacts induced by dense materials are the drawback of CBCT imaging and the peri-implant bone condition may not be assessed reliably because the artifacts are present in the same area. This pilot study investigates the performance of the artifact reduction algorithm (ARA) of the Planmeca Viso G7 CBCT device (Planmeca, Helsinki, Finland) with three different implant materials and imaging parameters.Methods: Three pairs of dental implants consisting of titanium, zirconia, and fiber reinforced composite (FRC) were set into a pig mandible. A vertical defect simulating peri-implantitis bone loss was made on the buccal side of one of each implant. The defect was identified and measured by two observers and compared to the actual dimensions. In addition, the bone structure and the marginal cortex visibility between the implants were estimated visually.Results: The bone defect and its dimensions with the zirconia implant could not be identified in any image with or without the metal artifact reduction algorithm. The bone defect of titanium and FRC implants were identified with all three imaging parameters or even without ARA. The interobserver agreement between the two observers was almost perfect for all categories analyzed.Conclusion: Peri-implantitis defect of the zirconia implant and the peri-implant bone structure of the zirconia implants cannot be recognized reliably with any ARA levels, or any imaging parameters used with the Planmeca Viso G7. The need for ARA when imaging the peri-implant bone condition of the titanium and FRC implants may be unnecessary.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Blood and fibroblast responses to thermoset BisGMA-TEGDMA/glass fiber-reinforced composite implants in vitro
    Abdulmajeed, Aous A.
    Walboomers, X. F.
    Massera, Jonathan
    Kokkari, Anne K.
    Vallittu, Pekka K.
    Narhi, Timo O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (07) : 843 - 851
  • [2] Candida albicans adhesion on reinforced polymethylmethacrylate denture resin: effect of fibre architecture and exposure to saliva
    Akalin-Evren, Buket
    Kulak-Ozkan, Yasemin
    Ozcan, Mutlu
    Kadir, Tanju
    [J]. GERODONTOLOGY, 2014, 31 (03) : 194 - 201
  • [3] Bone tissue responses to glass fiber-reinforced composite implants - a histomorphometric study
    Ballo, A. M.
    Akca, E. A.
    Ozen, T.
    Lassila, L.
    Vallittu, P. K.
    Narhi, T. O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (06) : 608 - 615
  • [4] Detection of simulated periodontal defects using cone-beam CT and digital intraoral radiography
    Bayat, Samaneh
    Talaeipour, Ahmad Reza
    Sarlati, Fatemeh
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (06)
  • [5] Correlation of Three-Dimensional Radiologic Data with Subsequent Treatment Approach in Patients with Peri-implantitis: A Retrospective Analysis
    Bender, Philip
    Salvi, Giovanni E.
    Buser, Daniel
    Sculean, Anton
    Bornstein, Michael M.
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2017, 37 (04) : 481 - 489
  • [6] In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography
    Benic, Goran I.
    Sancho-Puchades, Manuel
    Jung, Ronald E.
    Deyhle, Hans
    Haemmerle, Christoph H. F.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) : 378 - 383
  • [7] Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions
    Berglundh, Tord
    Armitage, Gary
    Araujo, Mauricio G.
    Avila-Ortiz, Gustavo
    Blanco, Juan
    Camargo, Paulo M.
    Chen, Stephen
    Cochran, David
    Derks, Jan
    Figuero, Elena
    Hammerle, Christoph H. F.
    Heitz-Mayfield, Lisa J. A.
    Guy Huynh-Ba
    Iacono, Vincent
    Koo, Ki-Tae
    Lambert, France
    McCauley, Laurie
    Quirynen, Marc
    Renvert, Stefan
    Salvi, Giovanni E.
    Schwarz, Frank
    Tarnow, Dennis
    Tomasi, Cristiano
    Wang, Hom-Lay
    Zitzmann, Nicola
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2018, 45 : S286 - S291
  • [8] Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research
    Bornstein, Michael M.
    Horner, Keith
    Jacobs, Reinhilde
    [J]. PERIODONTOLOGY 2000, 2017, 73 (01) : 51 - 72
  • [9] Flexural strengths of fiber-reinforced composites polymerized with conventional light-curing and additional postcuring
    Cacciafesta, Vittorio
    Sfondrini, Maria Francesca
    Lena, Alessandro
    Scribante, Andrea
    Vallittu, Pekka K.
    Lassila, Lippo V.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 132 (04) : 524 - 527
  • [10] Distinguishing predictive profiles for patient-based risk assessment and diagnostics of plaque induced, surgically and prosthetically triggered peri-implantitis
    Canullo, Luigi
    Tallarico, Marco
    Radovanovic, Sandro
    Delibasic, Boris
    Covani, Ugo
    Rakic, Mia
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (10) : 1243 - 1250