Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study

被引:9
作者
Kuusisto, Niina [1 ,2 ]
Abushahba, Faleh [3 ]
Syrjanen, Stina [1 ]
Huumonen, Sisko [4 ,5 ]
Vallittu, Pekka [6 ,7 ,8 ]
Narhi, Timo [3 ]
机构
[1] Univ Turku, Inst Dent, Dept Oral Pathol & Radiol, Turku, Finland
[2] Paijat Hame Cent Hosp, Dept Radiol, Lahti, Finland
[3] Univ Turku, Inst Dent, Dept Prosthet Dent & Stomatognath Physiol, Turku, Finland
[4] Univ Eastern Finland, Inst Dent, Kuopio, Finland
[5] Kuopio Univ Hosp, Diagnost Imaging Ctr, Kuopio, Finland
[6] Univ Turku, Inst Dent, Dept Biomat Sci, Turku, Finland
[7] Univ Turku, Inst Dent, Turku Clin Biomat Ctr TCBC, Turku, Finland
[8] Welf Div, City Of Turku, Finland
关键词
peri-implantitis; artifact; cone beam computed tomography; FIBER-REINFORCED COMPOSITE; DENTAL IMPLANTS; RADIOGRAPHY; DIAGNOSIS; ACCURACY;
D O I
10.1259/dmfr.20230252
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Three-dimensional cone beam computed tomography (CBCT) imaging can be considered, especially in patients with complicated peri-implantitis (PI). Artifacts induced by dense materials are the drawback of CBCT imaging and the peri-implant bone condition may not be assessed reliably because the artifacts are present in the same area. This pilot study investigates the performance of the artifact reduction algorithm (ARA) of the Planmeca Viso G7 CBCT device (Planmeca, Helsinki, Finland) with three different implant materials and imaging parameters.Methods: Three pairs of dental implants consisting of titanium, zirconia, and fiber reinforced composite (FRC) were set into a pig mandible. A vertical defect simulating peri-implantitis bone loss was made on the buccal side of one of each implant. The defect was identified and measured by two observers and compared to the actual dimensions. In addition, the bone structure and the marginal cortex visibility between the implants were estimated visually.Results: The bone defect and its dimensions with the zirconia implant could not be identified in any image with or without the metal artifact reduction algorithm. The bone defect of titanium and FRC implants were identified with all three imaging parameters or even without ARA. The interobserver agreement between the two observers was almost perfect for all categories analyzed.Conclusion: Peri-implantitis defect of the zirconia implant and the peri-implant bone structure of the zirconia implants cannot be recognized reliably with any ARA levels, or any imaging parameters used with the Planmeca Viso G7. The need for ARA when imaging the peri-implant bone condition of the titanium and FRC implants may be unnecessary.
引用
收藏
页数:13
相关论文
共 50 条
[1]   Blood and fibroblast responses to thermoset BisGMA-TEGDMA/glass fiber-reinforced composite implants in vitro [J].
Abdulmajeed, Aous A. ;
Walboomers, X. F. ;
Massera, Jonathan ;
Kokkari, Anne K. ;
Vallittu, Pekka K. ;
Narhi, Timo O. .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (07) :843-851
[2]   Candida albicans adhesion on reinforced polymethylmethacrylate denture resin: effect of fibre architecture and exposure to saliva [J].
Akalin-Evren, Buket ;
Kulak-Ozkan, Yasemin ;
Ozcan, Mutlu ;
Kadir, Tanju .
GERODONTOLOGY, 2014, 31 (03) :194-201
[3]   Bone tissue responses to glass fiber-reinforced composite implants - a histomorphometric study [J].
Ballo, A. M. ;
Akca, E. A. ;
Ozen, T. ;
Lassila, L. ;
Vallittu, P. K. ;
Narhi, T. O. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (06) :608-615
[4]   Detection of simulated periodontal defects using cone-beam CT and digital intraoral radiography [J].
Bayat, Samaneh ;
Talaeipour, Ahmad Reza ;
Sarlati, Fatemeh .
DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (06)
[5]   Correlation of Three-Dimensional Radiologic Data with Subsequent Treatment Approach in Patients with Peri-implantitis: A Retrospective Analysis [J].
Bender, Philip ;
Salvi, Giovanni E. ;
Buser, Daniel ;
Sculean, Anton ;
Bornstein, Michael M. .
INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2017, 37 (04) :481-489
[6]   In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography [J].
Benic, Goran I. ;
Sancho-Puchades, Manuel ;
Jung, Ronald E. ;
Deyhle, Hans ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) :378-383
[7]   Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions [J].
Berglundh, Tord ;
Armitage, Gary ;
Araujo, Mauricio G. ;
Avila-Ortiz, Gustavo ;
Blanco, Juan ;
Camargo, Paulo M. ;
Chen, Stephen ;
Cochran, David ;
Derks, Jan ;
Figuero, Elena ;
Hammerle, Christoph H. F. ;
Heitz-Mayfield, Lisa J. A. ;
Guy Huynh-Ba ;
Iacono, Vincent ;
Koo, Ki-Tae ;
Lambert, France ;
McCauley, Laurie ;
Quirynen, Marc ;
Renvert, Stefan ;
Salvi, Giovanni E. ;
Schwarz, Frank ;
Tarnow, Dennis ;
Tomasi, Cristiano ;
Wang, Hom-Lay ;
Zitzmann, Nicola .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2018, 45 :S286-S291
[8]   Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research [J].
Bornstein, Michael M. ;
Horner, Keith ;
Jacobs, Reinhilde .
PERIODONTOLOGY 2000, 2017, 73 (01) :51-72
[9]   Flexural strengths of fiber-reinforced composites polymerized with conventional light-curing and additional postcuring [J].
Cacciafesta, Vittorio ;
Sfondrini, Maria Francesca ;
Lena, Alessandro ;
Scribante, Andrea ;
Vallittu, Pekka K. ;
Lassila, Lippo V. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 132 (04) :524-527
[10]   Distinguishing predictive profiles for patient-based risk assessment and diagnostics of plaque induced, surgically and prosthetically triggered peri-implantitis [J].
Canullo, Luigi ;
Tallarico, Marco ;
Radovanovic, Sandro ;
Delibasic, Boris ;
Covani, Ugo ;
Rakic, Mia .
CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (10) :1243-1250