A graphene oxide/polyaniline nanocomposite biosensor: synthesis, characterization, and electrochemical detection of bilirubin

被引:33
作者
Ahmed, Noor sabah [1 ]
Hsu, Chou-Yi [2 ]
Mahmoud, Zaid H. [3 ]
Sayadi, Hamidreza [4 ]
Kianfar, Ehsan [5 ,6 ]
机构
[1] Univ Diyala, Coll Sci, Diyala, Iraq
[2] Chia Nan Univ Pharm & Sci, Dept Pharm, Tainan, Taiwan
[3] Univ Diyala, Coll Sci, Chem Dept, Diyala, Iraq
[4] Fac Shahrood Branch, Dept Chem Engn, Shahrood Branch, Shahrood, Iran
[5] Islamic Azad Univ, Dept Chem Engn, Arak Branch, Arak, Iran
[6] Islamic Azad Univ, Gachsaran Branch, Young Researchers & Elite Club, Gachsaran, Iran
关键词
SENSITIVE DETECTION; OXIDE NANOSHEETS; MEMBRANES; SERUM; NANOPARTICLES; SEPARATION; SENSOR;
D O I
10.1039/d3ra06815c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The level of free bilirubin is a considerable index for the characterization of jaundice-related diseases. Herein, a biosensor was fabricated via the immobilization of bilirubin oxidase (BOx) on graphene oxide (GO) and polyaniline (PANI) that were electrochemically co-precipitated on indium tin oxide (ITO) conductive glass. The structural enzyme electrode was characterized by FTIR, XRD, and Raman spectroscopy, while the spectral and thermal properties were investigated by UV-vis and thermogravimetric analysis (TGA). Owing to the activity of the fabricated BOx/GO@PANI/ITO biosensor, it could detect free bilirubin with good selectivity and sensitivity in a low response time. The electrochemical response was studied using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). At polarization potential 0.2 V vs. Ag/AgCl, the fabricated sensor illustrated a response in only 2 s at 30 degrees C and pH 7.5. The LOD and LOQ for the BOx/GO@PANI/ITO biosensor were calculated and found to be 0.15 nM and 2.8 nM, respectively. The electrochemical signal showed a linear response in the concentration range 0.01-250 mu M. At 5 degrees C, the biosensor demonstrated a half-time of 120 days, through which it could be utilized 100 times at this temperature conditions. By using a common colorimetric method, the data on bilirubin levels in serum showed a determination coefficient (R2) of 0.97. The level of free bilirubin is a considerable index for the characterization of jaundice-related diseases.
引用
收藏
页码:36280 / 36292
页数:13
相关论文
共 88 条
[1]   Preparing Hybrid Nanocomposites on the Basis of Resole/Graphene/Carbon Fibers for Investigating Mechanical and Thermal Properties [J].
Abbas, Zainab Sabri ;
Kadhim, Mustafa M. ;
Rheima, Ahmed Mahdi ;
Al-bayati, Alaa Dhari Jawad ;
Abed, Zainab Talib ;
Al-Jaafari, Firas Mohamed Dashoor ;
Jaber, Asala Salam ;
Hachim, Safa K. ;
Mahmoud, Zaid H. ;
Ali, Farah K. ;
Koten, Hasan ;
Kianfar, Ehsan .
BIONANOSCIENCE, 2023, 13 (03) :983-1011
[2]   RETRACTED: Comparison and evaluation of the performance of graphene-based biosensors (Retracted article. See vol. 35, pg. 917, 2025) [J].
Abdelbasset, Walid Kamal ;
Jasim, Saade Abdalkareem ;
Bokov, Dmitry Olegovich ;
Oleneva, Maria Sergeevna ;
Islamov, Anvar ;
Hammid, Ali Thaeer ;
Mustafa, Yasser Fakri ;
Yasin, Ghulam ;
Alguno, Arnold C. ;
Kianfar, Ehsan .
CARBON LETTERS, 2022, 32 (04) :927-951
[3]  
Abdul-Reda Hussein U., 2024, Braz. J. Biol., V84, pe264947, DOI 10.1590/1519-6984.264947
[4]  
AbdulKareem E. A., 2023, CASE STUD CHEM ENV E, V8
[5]  
Ahmad N, 2022, KOREAN J CHEM ENG, V39, P3155, DOI 10.1007/s11814-022-1164-6
[6]  
Al-Awsi G. R. L., 2023, Braz. J. Biol, V84
[7]  
Al-Obaidi NS, 2018, PHARMACOPHORE, V9, P61
[8]  
Al-Salman H. N. K., 2023, CASE STUDIES CHEM EN, V8, DOI DOI 10.1016/J.CSCEE.2023.100426
[9]  
Alabada R., 2023, Case Stud. Chem. Environ. Eng.
[10]   A Cu-CNF-rGO-functionalized carbon film indicated as a versatile electrode for sensing of biomarkers using electropolymerized recognition elements [J].
Ali, Haider ;
Verma, Nishith .
JOURNAL OF MATERIALS SCIENCE, 2022, 57 (11) :6345-6360