Minimally invasive CAD/CAM lithium disilicate partial-coverage restorations show superior in-vitro fatigue performance than single crowns

被引:3
作者
Spitznagel, F. A. [1 ,2 ,3 ]
Prott, L. S. [1 ,2 ,6 ,7 ]
Hoppe, J. S. [1 ,2 ]
Manitckaia, T. [1 ,2 ]
Blatz, M. B. [3 ]
Zhang, Y. [3 ]
Langner, R. [4 ,5 ]
Gierthmuehlen, P. C. [1 ,2 ]
机构
[1] Heinrich Heine Univ, Med Fac, Dept Prosthodont, Dusseldorf, Germany
[2] Heinrich Heine Univ, Univ Hosp Dusseldorf, Dusseldorf, Germany
[3] Univ Penn, Dept Prevent & Restorat Sci, Penn Dent Med, Philadelphia, PA USA
[4] Heinrich Heine Univ Dusseldorf, Inst Syst Neurosci, Med Fac, Dusseldorf, Germany
[5] Res Ctr Julich, Inst Neurosci & Med Brain & Behav INM-7, Julich, Germany
[6] Heinrich Heine Univ, Med Fac, Dept Prosthodont, Moorenstr 5, D-40225 Dusseldorf, Germany
[7] Heinrich Heine Univ, Univ Hosp Dusseldorf, Moorenstr 5, D-40225 Dusseldorf, Germany
关键词
ceramics; computer-aided design; fatigue; full-veneer; partial-coverage restoration; FRACTURE-RESISTANCE; OCCLUSAL VENEERS; POSTERIOR TEETH; MOLAR CROWNS; ZIRCONIA; WEAR; LOAD; THICKNESS; STRENGTH; SURVIVAL;
D O I
10.1111/jerd.13169
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To analyze the influence of restoration design (partial-coverage restoration vs. crown) and ceramic layer thickness on the performance and failure loads of CAD/CAM-fabricated lithium disilicate (LDS) reconstructions on molars after fatigue.Materials and Methods: Seventy-two posterior monolithic CAD/CAM-fabricated LDS restorations (IPS e.max CAD, Ivoclar Vivadent) with different occlusal/buccal ceramic layer thicknesses (1.5/0.8, 1.0/0.6, and 0.5/0.4 mm) and restoration designs (PCR: non-retentive full-veneer/partial-coverage restoration, C: crown,) were investigated and divided into six groups (n = 12, test: PCR-1.5, PCR-1.0, PCR-0.5; control: C-1.5, C-1.0, C-0.5). LDS restorations were adhesively bonded (Variolink Esthetic DC, Ivoclar Vivadent) to dentin-analogue composite dies (Z100, 3M ESPE). All specimens were subjected to thermomechanical loading (1.2 million cycles, 49 N, 1.6 Hz, 5-55 degrees C) and exposed to single load to failure testing. Failure analysis was performed with light and scanning electron microscopies. Data were statistically analyzed using ANOVA, Tukey-Test, and t-test (p < 0.05).Results: Eight crown samples (C-0.5) and one PCR specimen (PCR-0.5) revealed cracks after fatigue, resulting in an overall success rate of 87.5% (crowns: 75%, PCRs: 96.88%). Direct comparisons of PCRs versus crowns for thicknesses of 0.5 mm (p < 0.001) and 1.0 mm (p = 0.004) were significant and in favor of PCRs. Minimally invasive PCRs (0.5 and 1.0 mm) outperformed crowns with the identical ceramic thickness. No difference was detected (p = 0.276) between thickness 1.5 mm PCRs and crowns.Conclusions: Minimally invasive monolithic CAD/CAM-fabricated posterior LDS PCRs (0.5 and 1.0 mm) resulted in superior failure load values compared to minimally invasive crowns. Minimally invasive crowns (0.5 mm) are prone to cracks after fatigue.
引用
收藏
页码:94 / 106
页数:13
相关论文
共 63 条
  • [11] Clinical performance of occlusal onlays made of lithium disilicate ceramic in patients with severe tooth wear up to 11 years
    Edelhoff, D.
    Gueth, J. F.
    Erdelt, K.
    Brix, O.
    Liebermann, A.
    [J]. DENTAL MATERIALS, 2019, 35 (09) : 1319 - 1330
  • [12] Edelhoff D, 2002, INT J PERIODONT REST, V22, P241
  • [13] Pressable lithium disilicate ceramic versus CAD/CAM resin composite restorations in patients with moderate to severe tooth wear: Clinical observations up to 13 years
    Edelhoff, Daniel
    Erdelt, Kurt-Juergen
    Stawarczyk, Bogna
    Liebermann, Anja
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (01) : 116 - 128
  • [14] Biting and chewing in overdentures, full dentures, and natural dentitions
    Fontijn-Tekamp, FA
    Slagter, AP
    Van Der Bilt, A
    Van 'T Hof, MA
    Witter, DJ
    Kalk, W
    Jansen, JA
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 (07) : 1519 - 1524
  • [15] Influence of ceramic thickness and dental substrate on the survival rate and failure load of non-retentive occlusal veneers after fatigue
    Gierthmuehlen, Petra C.
    Spitznagel, Frank A.
    Koschate, Maximilian
    Bonfante, Estevam A.
    Prott, Lea S.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (02) : 373 - 380
  • [16] Posterior minimally invasive full-veneers: Effect of ceramic thicknesses, bonding substrate, and preparation designs on failure-load and -mode after fatigue
    Gierthmuehlen, Petra C.
    Jerg, Annika
    Fischer, Johannes Benjamin
    Bonfante, Estevam A.
    Spitznagel, Frank A.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (01) : 145 - 153
  • [17] Grand View Research Inc, 2019, DENT CROWNS BRIDG MA
  • [18] Guess PC, 2013, J PROSTHET DENT, V110, P264, DOI 10.1016/S0022-3913(13)60374-1
  • [19] Monolithic Zirconia Partial Coverage Restorations: An In Vitro Mastication Simulation Study
    Gupta, Savita
    Abdulmajeed, Awab
    Donovan, Terry
    Boushell, Lee
    Bencharit, Sompop
    Sulaiman, Taiseer A.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (01): : 76 - 82
  • [20] Using a chewing simulator for fatigue testing of metal ceramic crowns
    Heintze, S. D.
    Eser, A.
    Monreal, D.
    Rousson, V.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 65 : 770 - 780