Optimized detector configurations for the reconstruction of phase-contrast images in scanning transmission electron microscopy

被引:1
作者
Oster, Alex [1 ]
Kohl, Helmut [1 ]
机构
[1] Univ Munster, Westfal Wilhelms Univ Munster, Wilhelm Klemm Str, D-48149 Munster, Germany
关键词
Scanning Transmission Electron Microscopy; Phase contrast transfer; Signal-to-noise ratio; Optimized detector geometries; Pixelated detector; 4D-STEM; Phase contrast methods; Image formation;
D O I
10.1016/j.ultramic.2022.113670
中图分类号
TH742 [显微镜];
学科分类号
摘要
Using the differential phase contrast mechanism and anti-symmetric detector geometries it is possible to image distributions of electric and magnetic fields in a scanning transmission electron microscope. Different detector geometries can be used for imaging and, due to their efficiency, mainly ring quadrant detectors and pixelated detectors have been used in recent high resolution differential phase contrast experiments. In 4D-Scanning Transmission Electron Microscopy one uses a pixelated (2D) detector to obtain the complete scattering distribution for every (2D) image point. The accuracy of pixelated detectors increases with an increasing number of pixels, which in turn also leads to a larger amount of data that needs to be evaluated. To reduce the required numerical effort, we are looking for alternative detector geometries by further segmenting ring quadrant detectors. To compare the different geometries, their signal-to-noise ratios are calculated for an ideal STEM and several weak phase objects. Images can be obtained by combining the data of different detector pixels using a scheme similar to a reconstruction from a focal series. The procedure can be interpreted as the simplest example of ptychography including only the first-order diffraction disks. Our results show that a 50-segment annular bright-field detector can reach a signal-to-noise ratio close to that of a 128 x 128 pixelated detector, while having a significantly lower number of segments that need to be evaluated.
引用
收藏
页数:7
相关论文
共 14 条
[1]  
Bosch E.G. T., 2016, Microsc. Microanal, V22, P306, DOI [10.1017/s1431927616002385, DOI 10.1017/S1431927616002385]
[2]  
DEKKERS NH, 1974, OPTIK, V41, P452
[3]  
Glauber R.J., 1959, Lectures on Theoretical Physics
[4]   OPTIMUM ROTATIONALLY SYMMETRICAL DETECTOR CONFIGURATIONS FOR PHASE-CONTRAST IMAGING IN SCANNING-TRANSMISSION ELECTRON-MICROSCOPY [J].
HAMMEL, M ;
ROSE, H .
ULTRAMICROSCOPY, 1995, 58 (3-4) :403-415
[5]  
Hammel M., 1992, OPTIMALE DETEKTORSTR
[6]   DYNAMIC THEORY OF CRYSTALLINE STRUCTURE ANALYSIS BY ELECTRON DIFFRACTION IN INHOMOGENEOUS PRIMARY WAVE FIELD [J].
HEGERL, R ;
HOPPE, W .
BERICHTE DER BUNSEN-GESELLSCHAFT FUR PHYSIKALISCHE CHEMIE, 1970, 74 (11) :1148-&
[7]   High-resolution STEM imaging with a quadrant detector Conditions for differential phase contrast microscopy in the weak phase object approximation [J].
Majert, S. ;
Kohl, H. .
ULTRAMICROSCOPY, 2015, 148 :81-86
[8]   Comparison of first moment STEM with conventional differential phase contrast and the dependence on electron dose [J].
Mueller-Caspary, Knut ;
Krause, Florian F. ;
Winkler, Florian ;
Beche, Armand ;
Verbeeck, Johan ;
Van Aert, Sandra ;
Rosenauer, Andreas .
ULTRAMICROSCOPY, 2019, 203 (95-104) :95-104
[9]   Four-Dimensional Scanning Transmission Electron Microscopy (4D-STEM): From Scanning Nanodiffraction to Ptychography and Beyond [J].
Ophus, Colin .
MICROSCOPY AND MICROANALYSIS, 2019, 25 (03) :563-582
[10]  
Reimer L., 2008, Transmission electron microscopy, DOI [10.1007/978-0-387-40093-8, DOI 10.1007/978-0-387-40093-8]