Comparison of a Presbyopia-Correcting Supplementary Intraocular Lens Combination and a Capsular-Bag Lens: An In Vitro Study

被引:3
|
作者
Khoramnia, Ramin [1 ]
Baur, Isabella Diana [1 ]
Yan, Weijia [1 ]
Labuz, Grzegorz [1 ]
Auffarth, Gerd Uwe [1 ]
机构
[1] Heidelberg Univ, David J Apple Ctr Vis Res, Dept Ophthalmol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
polypseudophakia; trifocality; optical quality; OPTICAL-QUALITY DIFFERENCES; IMPLANTATION; CATARACT; OUTCOMES; ADD;
D O I
10.3390/diagnostics13081482
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the optical quality of two approaches to trifocality: polypseudophakia versus monopseudophakia. The combination (polypseudophakia) of a monofocal Basis Z B1AWY0 and AddOn Trifocal A4DW0M intraocular lens (IOL) was compared to using one Basis Z Trifocal B1EWYN IOL, all from 1stQ GmbH. In both approaches, we measured modulation transfer function (MTF) and Strehl Ratio (SR) values at 3.0 and 4.5 mm pupil sizes. We determined the through-focus (TF) MTF at 25, 50 and 100 lp/mm for the 3 mm aperture. United States Air Force (USAF) target images were recorded. MTF measurement of the trifocal lens and the combined monofocal and trifocal AddOn IOL showed good performance at the far and near focus for the 3 mm aperture. For the 4.5 mm aperture the MTF improved for the far focus but decreased for the intermediate and near focus. TF MTF showed better contrast at the far focus for the polypseudophakic setup but at the expense of the efficiency at the near focus. However, the USAF chart images revealed only minimal differences between both approaches. The optical quality of the polypseudophakic approach was not affected by the presence of two IOLs instead of one and proved to be comparable with the performance of one capsular-bag-fixated trifocal IOL. Differences between the single vs. two-lens approach seen in the TF MTF analysis could be attributed to the optical design that varied between the trifocal models.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effect of total lens epithelial cell destruction on intraocular lens fixation in the human capsular bag
    Spalton, David J.
    Russell, Sarah L.
    Evans-Gowing, Richard
    Eldred, Julie A.
    Wormstone, I. Michael
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (02) : 306 - 312
  • [22] Visual outcomes and patient satisfaction after implantation of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and multifocal profiles
    Ribeiro, Filomena J.
    Ferreira, Tiago B.
    Silva, Diana
    Matos, Ana Claudia
    Gaspar, Sylvia
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (11) : 1448 - 1453
  • [23] Multifocal Intraocular Lens Results in Correcting Presbyopia in Eyes After Radial Keratotomy
    Kim, Kyeong Hwan
    Seok, Kyung-won
    Kim, Wan Soo
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (06): : E22 - E25
  • [24] Posterior capsule opacification and capsular bag performance of a microincision intraocular lens
    Gangwani, Vinod
    Hirnschall, Nino
    Koshy, John
    Crnej, Alja
    Nishi, Yutaro
    Maurino, Vincenzo
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) : 1988 - 1992
  • [25] Novel trocar assisted intraocular lens and capsular bag complex fixation
    Parkash, Rohit Om
    Gurnani, Bharat
    Kaur, Kirandeep
    Parkash, Tushya Om
    Vajpayee, Rasik B.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (02) : 583 - 588
  • [26] Scleral fixation of Carlevale intraocular lens: A new tool in correcting aphakia with no capsular support
    Georgalas, Ilias
    Spyropoulos, Dimitrios
    Gotzaridis, Stratos
    Papakonstantinou, Evangelia
    Kandarakis, Stylianos
    Kanakis, Menelaos
    Karamaounas, Aristotelis
    Petrou, Petros
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (01) : 527 - 533
  • [27] Recommendation for Presbyopia-Correcting Intraocular Lenses: A Delphi Consensus Statement by the ESASO Study Group
    Romano, Vito
    Madrid-Costa, David
    Alfonso, Jose F.
    Alio, Jorge
    Allan, Bruce
    Angunawela, Romesh
    Auffarth, Gerd
    Carones, Francesco
    Khoramnia, Ramin
    Moore, Johnny
    Nanavaty, Mayank A.
    Savini, Giacomo
    Pagano, Luca
    Romano, Mario R.
    Virgili, Gianni
    Fernandez-Vega-Cueto, Luis
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 253 : 169 - 180
  • [28] Geometry of Modern Presbyopia-Correcting Intraocular Lenses and Changes in Haptic-Capsular Bag Behavior According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography
    Borkenstein, Andreas F.
    Borkenstein, Eva-Maria
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (12) : 3059 - 3077
  • [29] Comparison of Five Presbyopia-Correcting Intraocular Lenses: Optical-Bench Assessment with Visual-Quality Simulation
    Labuz, Grzegorz
    Yan, Weijia
    Baur, Isabella D. D.
    Khoramnia, Ramin
    Auffarth, Gerd U. U.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)
  • [30] Comparison of Through-Focus Image Sharpness Across Five Presbyopia-Correcting Intraocular Lenses
    Pepose, Jay S.
    Wang, Daozhi
    Altmann, Griffith E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (01) : 20 - 28