Reliability of lateral wall-thickness measurement in trochanteric fractures and parameters associated with lateral wall integrity

被引:0
|
作者
Ratanakornphan, Chindarat [1 ]
Pikulhom, Thanachart [1 ]
Jenvorapoj, Somjet [2 ]
Amarase, Chavarin [2 ]
Tantavisut, Saran [2 ]
机构
[1] King Chulalongkorn Mem Hosp, Thai Red Cross Soc, Dept Radiol, Bangkok 10330, Thailand
[2] King Chulalongkorn Mem Hosp, Thai Red Cross Soc, Dept Orthopaed, Bangkok 10330, Thailand
关键词
AO/OTA classification; fracture parameter; hip fractures; lateral wall thickness; reliability;
D O I
10.2478/abm-2024-0005
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background The AO Foundation/Orthopaedic Trauma Association (AO/OTA) introduced a new trochanteric fracture classification in January 2018, concerning the lateral wall integrity. It suggested the intramedullary nail fixation in patients with an incompetent lateral wall fracture. Objective To determine the reliability of lateral wall-thickness measurement and the fracture parameters associated with lateral wall integrity. Methods This retrospective study evaluated patients with an intertrochanteric fracture who had had surgery in King Chulalongkorn Memorial Hospital between January 2014 and January 2019. The lateral wall was measured by anteroposterior plain radiography by four raters, two times each. The demographic data and fracture parameters were assessed and compared with respect to lateral wall integrity. Result In a total of 236 femurs and 232 patients having the 2018 AO/OTA-specified 31A1 and 31A2 intertrochanteric fractures, the lateral wall-thickness measurement showed excellent inter-rater reliability at 0.944 (0.927-0.957) and good-to-excellent intra-rater reliability ranging from 0.835 to 0.972. The parameters associated with lateral wall incompetence as per the multivariate logistic regression analysis were fracture angle (odds ratio [OR] = 0.95), distal greater trochanter involvement (OR = 9.47), and fragments at the intertrochanter area (OR = 4.49) and at the lesser trochanter (OR = 2.6). Conclusion Some of the parameters related to trochanteric fractures are associated with lateral wall incompetence. Lateral wall-thickness measurement is a reproducible method, which has been suggested for use by the AO/OTA 2018 classification. It is easy to use and can help select the appropriate treatment for intertrochanteric fracture patients.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [1] Lateral femoral wall thickness in trochanteric hip fractures: a systematic review
    Selim, Amr
    Ponugoti, Nikhil
    Daoub, Ahmed
    Johnson-Lynn, Sarah
    Rhee, Shin Jae
    HIP INTERNATIONAL, 2024, 34 (05) : 668 - 676
  • [2] Unstable trochanteric fractures: the role of lateral wall reconstruction
    Gupta, R. K.
    Sangwan, Kapil
    Kamboj, Pradeep
    Punia, Sarabjeet S.
    Walecha, Pankaj
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (01) : 125 - 129
  • [3] Unstable trochanteric fractures: the role of lateral wall reconstruction
    R. K. Gupta
    Kapil Sangwan
    Pradeep Kamboj
    Sarabjeet S. Punia
    Pankaj Walecha
    International Orthopaedics, 2010, 34 : 125 - 129
  • [4] Relative lateral wall thickness is an improved predictor for postoperative lateral wall fracture after trochanteric femoral fracture osteosynthesis
    van Knegsel, Kenneth P.
    Hsu, C. -E.
    Huang, K. -C.
    Benca, Emir
    Pastor, Torsten
    Ganse, Bergita
    Varga, Peter
    Gueorguiev, Boyko
    Knobe, Matthias
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [5] Integrity of the lateral femoral wall in intertrochanteric hip fractures
    Garg, Bhavuk
    Malhotra, Rajesh
    Jayaswal, Arvind
    Kotwal, P. P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (08): : 1868 - 1868
  • [6] Relative lateral wall thickness is an improved predictor for postoperative lateral wall fracture after trochanteric femoral fracture osteosynthesis
    Kenneth P. van Knegsel
    C.-E. Hsu
    K.-C. Huang
    Emir Benca
    Torsten Pastor
    Bergita Ganse
    Peter Varga
    Boyko Gueorguiev
    Matthias Knobe
    Scientific Reports, 13
  • [7] PULSE METHOD OF WALL-THICKNESS MEASUREMENT
    RAIKHMAN, AZ
    INDUSTRIAL LABORATORY, 1961, 27 (02): : 170 - 171
  • [8] Lateral femoral wall thickness A RELIABLE PREDICTOR OF POST-OPERATIVE LATERAL WALL FRACTURE IN INTERTROCHANTERIC FRACTURES
    Hsu, C-E.
    Shih, C-M.
    Wang, C-C.
    Huang, K-C.
    BONE & JOINT JOURNAL, 2013, 95B (08): : 1134 - 1138
  • [9] LIMITS OF WALL-THICKNESS MEASUREMENT WITH ULTRASONIC THICKNESS GAUGES
    FRIELINGHAUS, R
    CARODISKEY, T
    MATERIALS EVALUATION, 1985, 43 (10) : 1310 - 1310
  • [10] Traction images heavily influence lateral wall measurement in trochanteric hip fractures. A prospective study
    Carmona, Maximiliano
    Gonzalez, Nicolas
    Segovia, Javier
    de Amesti, Martin
    Zamora, Tomas
    Schweitzer, Daniel
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54