Online adaptive radiotherapy for bladder cancer using a simultaneous integrated boost and fiducial markers

被引:12
作者
Azzarouali, Sana [1 ,2 ,3 ]
Goudschaal, Karin [2 ,3 ]
Visser, Jorrit [2 ,3 ]
Hulshof, Maarten [2 ,3 ]
Admiraal, Marjan [1 ,2 ]
van Wieringen, Niek [2 ,3 ]
Nieuwenhuijzen, Jakko [2 ,4 ]
Wiersma, Jan [2 ,3 ]
Daniels, Laurien [2 ,3 ]
den Boer, Duncan [1 ,2 ]
Bel, Arjan [2 ,3 ]
机构
[1] Vrije Univ Amsterdam, Radiat Oncol, Amsterdam UMC locat, Amsterdam, Netherlands
[2] Canc Ctr Amsterdam, Canc Therapy Treatment & qual life, Amsterdam, Netherlands
[3] Univ Amsterdam, Radiat Oncol, Amsterdam UMC locat, Meibergdreef 9, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, Amsterdam UMC locat, De Boelelaan 1117, Amsterdam, Netherlands
关键词
Online adaptive radiotherapy; Bladder cancer; Fiducial markers; Reoptimization; Artificial intelligence; Radiotherapy; CBCT; Focal boost; Cone Beam CT; RADIATION-THERAPY; RADICAL CYSTECTOMY; GUIDED RADIOTHERAPY; SELECTION; VOLUME; VARIABILITY; OUTCOMES; MOTION; TUMOR;
D O I
10.1186/s13014-023-02348-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeThe aim was to assess the feasibility of online adaptive radiotherapy (oART) for bladder cancer using a focal boost by focusing on the quality of the online treatment plan and automatic target delineation, duration of the workflow and performance in the presence of fiducial markers for tumor bed localization.MethodsFifteen patients with muscle invasive bladder cancer received daily oART with Cone Beam CT (CBCT), artificial intelligence (AI)-assisted automatic delineation of the daily anatomy and online plan reoptimization. The bladder and pelvic lymph nodes received a total dose of 40 Gy in 20 fractions, the tumor received an additional simultaneously integrated boost (SIB) of 15 Gy. The dose distribution of the reference plan was calculated for the daily anatomy, i.e. the scheduled plan. Simultaneously, a reoptimization of the plan was performed i.e. the adaptive plan. The target coverage and V95% outside the target were evaluated for both plans. The need for manual adjustments of the GTV delineation, the duration of the workflow and the influence of fiducial markers were assessed.ResultsAll 300 adaptive plans met the requirement of the CTV-coverage V95%>= 98% for both the boost (55 Gy) and elective volume (40 Gy). For the scheduled plans the CTV-coverage was 53.5% and 98.5%, respectively. Significantly less tissue outside the targets received 55 Gy in case of the adaptive plans as compared to the scheduled plans. Manual corrections of the GTV were performed in 67% of the sessions. In 96% of these corrections the GTV was enlarged and resulted in a median improvement of 1% for the target coverage. The median on-couch time was 22 min. A third of the session time consisted of reoptimization of the treatment plan. Fiducial markers were visible on the CBCTs and aided the tumor localization.ConclusionsAI-driven CBCT-guided oART aided by fiducial markers is feasible for bladder cancer radiotherapy treatment including a SIB. The quality of the adaptive plans met the clinical requirements and fiducial markers were visible enabling consistent daily tumor localization. Improved automatic delineation to lower the need for manual corrections and faster reoptimization would result in shorter session time.
引用
收藏
页数:12
相关论文
共 41 条
[1]  
[Anonymous], 2010, Journal of the ICRU, V10, DOI DOI 10.1093/JICRUNDQ001
[2]   A systematic review and meta-analysis of clinical trials of bladder-sparing trimodality treatment for muscle-invasive bladder cancer (MIBC) [J].
Arcangeli, Giorgio ;
Arcangeli, Stefano ;
Strigari, Lidia .
CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2015, 94 (01) :105-115
[3]  
Archambault Y, 2020, Med Phys Int J, V8, P77
[4]   Online adaptive radiotherapy of urinary bladder cancer with full re-optimization to the anatomy of the day: Initial experience and dosimetric benefits [J].
Astrom, Lina M. ;
Behrens, Claus P. ;
Calmels, Lucie ;
Sjostrom, David ;
Geertsen, Poul ;
Mouritsen, Lene Sonne ;
Serup-Hansen, Eva ;
Lindberg, Henriette ;
Sibolt, Patrik .
RADIOTHERAPY AND ONCOLOGY, 2022, 171 :37-42
[5]   BEHAVIOR OF LIPIODOL MARKERS DURING IMAGE GUIDED RADIOTHERAPY OF BLADDER CANCER [J].
Chai, Xiangfei ;
van Herk, Marcel ;
de Kamer, Jeroen B. van ;
Remeijer, Peter ;
Bex, Axel ;
Betgen, Anja ;
De Rejke, Theo M. ;
Hulshof, Maarten C. C. M. ;
Pos, Floris J. ;
Bel, Arjan .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (01) :309-314
[6]   A review of plan library approaches in adaptive radiotherapy of bladder cancer [J].
Collins, Shane D. ;
Leech, Michelle M. .
ACTA ONCOLOGICA, 2018, 57 (05) :566-573
[7]   Generalized overlap measures for evaluation and validation in medical image analysis [J].
Crum, William R. ;
Camara, Oscar ;
Hill, Derek L. G. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (11) :1451-1461
[8]   BioXmark® liquid fiducial markers for image-guided radiotherapy in muscle invasive bladder cancer: a safety and performance trial [J].
de Ridder, Mischa ;
Gerbrandy, Lara C. ;
de Reijke, Theo M. ;
Hinnen, Karel A. ;
Hulshof, Maarten C. C. M. .
BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1111)
[9]   Inter- and intra-fractional bladder motion during radiotherapy for bladder cancer: A comparison of full and empty bladders [J].
Dees-Ribbers, Hermine M. ;
Betgen, Anja ;
Pos, Floris J. ;
Witteveen, Thelma ;
Remeijer, Peter ;
van Herk, Marcel .
RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) :254-259
[10]   Image guided radiation therapy for bladder cancer: Assessment of bladder motion using implanted fiducial markers [J].
Della Biancia, Cesar ;
Yorke, Ellen ;
Kollmeier, Marisa A. .
PRACTICAL RADIATION ONCOLOGY, 2014, 4 (02) :108-115