Oval Root Canals Prepared With Two Different Endodontic Rotary Files: An In Vitro Study Comparing the Incidence of Dental Defects

被引:1
|
作者
Bhavsar, Bhavika A. [1 ]
Sharma, Pranjely [1 ]
Surana, Pratik [2 ]
Badnaware, Sheetal [3 ]
Jadhaw, Dimple [4 ]
Jain, Arvind [4 ]
机构
[1] RKDF Dent Coll & Res Ctr, Dept Conservat Dent & Endodont, Bhopal, India
[2] Maitri Coll Dent & Res Ctr, Dept Pedodont & Prevent Dent, Durg, India
[3] Banaras Hindu Univ, Fac Dent Sci, Dept Pedodont & Prevent Dent, Varanasi, Uttar Pradesh, India
[4] Govt Coll Dent, Dept Conservat Dent & Endodont, Indore, India
关键词
tooth wear; dentin; fracture; cracked teeth; sem; PROTAPER UNIVERSAL; ENLARGEMENT; CRACKS; HAND; GOLD;
D O I
10.7759/cureus.35914
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aims to investigate and compare the establishment of dentinal cracks during root canal preparation using a stereomicroscope and a scanning electron microscope (SEM). Materials and methods: Sixty removed human mandibular premolars were separated into three groups of 20: two experimental and one control. Within the randomized controlled experimental groups, root canals were constructed. Group I: the Waldent walflex file and Group II: the Trunatomy (TRN) file. Group III: the control group received no preparations. The surfaces of the roots were checked for dentinal cracks using a stereomicroscope and SEM following sectioning at 3, 6, and 9 mm from the apex. The Chi-square test was used to examine the data. Results: In the control group, no fissures appeared. Cracks in Waldent Walflex were almost 66.7% between the 3mm and 6mm range. At both the 6 mm and 9 mm levels, there was no statistically significant difference between the experimental groups (P > 0.05). Defects were found to be substantially higher in the apical region of samples than in the median and coronal sections. Conclusion: Dentinal fissures were created by every rotary file used in the tests. There were more flaws in the Waldent Walflex file group than in the Trunatomy file group.
引用
收藏
页数:7
相关论文
共 9 条
  • [1] A Comparative Examination of Cyclic Fatigue and Fragment Length of Three Different Types of Endodontic Rotary Files: An In Vitro Study
    Saleh, Hanaa Abduljabbar
    Abdulhameed, Othman Husham
    DENTAL HYPOTHESES, 2022, 13 (02): : 49 - 52
  • [2] EVALUATION OF APICAL TRANSPORTATION AND APICAL ROOT SEALING IN ROOT CANALS PREPARED WITH MTWO ROTARY SYSTEM WITH AND WITHOUT APICAL ENLARGEMENT - AN IN VITRO STUDY
    Souza, Matheus Albino
    De Carli, Joao Paulo
    Rodrigues, Fernando Tolfo
    Piuco, Larissa
    Bischoff, Karolina Frick
    Bervian, Juliane
    Zandona, Julia
    Doffo Winocur, Estela Marta
    Soares, Adriana de Jesus
    BIOSCIENCE JOURNAL, 2021, 37
  • [3] Micro-computed tomography evaluation of dentinal cracks after root canal preparation with different endodontic rotary files: An ex vivo study
    Alzamanan, Mohammed Mana
    Albassam, Abdullah Abdulrahman
    Khattab, Emad Mahmoud
    Alghamdi, Faisal Turki
    DENTAL AND MEDICAL PROBLEMS, 2025, 62 (01) : 89 - 98
  • [4] Comparative Evaluation of Incidence of Dentinal Defects After Root Canal Preparation Using Hand, Rotary, and Reciprocating Files: An Ex Vivo Study
    Das, Debanjan
    Barai, Sudipto
    Kumar, Rohit
    Bhattacharyya, Sourav
    Maity, Asim
    Shankarappa, Pushpa
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2022, 14 (01): : 78 - 85
  • [5] Cyclic fatigue resistance of two pediatric rotary files manufactured with different heat treatments: an in-vitro study
    Sandino-Lacayo, Krisna Lorena
    Vega-Gonzalez, Marina
    Soza-Bolanos, Ana Isabel
    Herrera-Alaniz, Laura Celeste
    Al Omari, Taher
    Dominguez-Perez, Ruben Abraham
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2024, 48 (05) : 102 - 109
  • [6] Morphological Changes of the Apical Foramen in Curved Root Canals After Use of Different Heat Treated NiTi Rotary Files: A Scanning Electron Microscopy Study
    Hamid, Tahira
    Malik, Azhar
    Kumar, Ajay
    Hamid, Saima
    Anjum, Shamim
    EUROPEAN ENDODONTIC JOURNAL, 2024, 9 (04): : 425 - 431
  • [7] Comparative evaluation of extrusion of apical debris in primary anterior teeth using two different rotary systems and hand files: An In Vitro study
    Asif, Ahsana
    Jeevanandan, Ganesh
    Govindaraju, Lavanya
    Vignesh, R.
    Subramanian, E. M. G.
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (03) : 512 - 516
  • [8] Comparative Analysis of Apical Root Crack Propagation after Root Canal Preparation at Different Instrumentation Lengths Using ProTaper Universal, ProTaper Next and ProTaper Gold Rotary Files: An In vitro Study
    Nishad, Sonalkumari Vakilram
    Shivamurthy, G. B.
    CONTEMPORARY CLINICAL DENTISTRY, 2018, 9 : S34 - S38
  • [9] Comparative Evaluation of Time Taken to Retrieve Gp Using Two Different Retreatment Files In Root Canal Treated Teeth- An In Vitro Study
    Sankar, Anjali
    Solete, Pradeep
    Jeevanandan, Ganesh
    Antony, S. Delphine Priscilla
    JOURNAL OF POPULATION THERAPEUTICS AND CLINICAL PHARMACOLOGY, 2023, 30 (10): : E392 - E398