Surface plasmon resonance biosensor sensitivity improvement employing of 2D materials and BaTiO3 with bimetallic layers of silver

被引:29
作者
Uniyal, Arun [1 ]
Pal, Amrindra [1 ]
Srivastava, Gaurav [2 ]
Rana, Md. Masud [3 ]
Taya, Sofyan A. [4 ]
Sharma, Amandeep [1 ]
Altahan, Baraa Riyadh [5 ]
Tomar, Sanjiv [1 ]
Singh, Yadvendra [6 ]
Parajuli, Deependra [7 ,8 ]
Smirani, Lassaad K. [9 ]
Ahammad, S. K. Hasane [10 ]
Rashed, Ahmed Nabih Zaki [11 ,12 ]
机构
[1] DIT Univ, Dept EECE, Dehra Dun 248009, India
[2] Univ Allahabad, Dept Elect & Commun, Allahabad, Nepal
[3] Rajshahi Univ Engn & Technol, Dept Elect & Elect Engn, Rajshahi, Bangladesh
[4] Islamic Univ Gaza, Phys Dept, POB 108, Gaza, Palestine
[5] Al Mustaqbal Univ Coll, Med Instrumentat Tech Engn Dept, Hilla 51001, Babil, Iraq
[6] Uttaranchal Univ, Uttaranchal Inst Technol, Dept Elect & Commun Engn, Dehra Dun 248009, India
[7] Tribhuvan Univ, Dept Phys, Trichandra Multiple Campus, Kathmandu 44600, Nepal
[8] Tribhuvan Univ, Res Ctr Appl Sci & Technol, Kirtipur, Nepal
[9] Umm Al Qura Univ, Elearning Deanship & Distance Educ, Mecca 24381, Saudi Arabia
[10] Koneru Lakshmaiah Educ Fdn, Dept ECE, Vaddeswaram 522302, Andhra Pradesh, India
[11] Menoufia Univ, Fac Elect Engn, Elect & Elect Commun Engn Dept, Menoufia 32951, Egypt
[12] SIMATS, Inst Elect & Commun Engn, Saveetha Sch Engn, Dept VLSI Microelect, Chennai 602105, Tamilnadu, India
关键词
ENHANCEMENT; MONOLAYER; TRANSITION; GRAPHENE; SENSOR;
D O I
10.1007/s10854-023-09821-w
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a surface plasmon resonance (SPR) biosensor built on bimetallic layers of Silver, BaTiO3, and transition metal dichalcogenide material (MoS2/MoSe2/WS2/WSe2) are proposed. The proposed SPR biosensor is based on the attenuated total reflection (ATR) method and relies on the Kretschmann configuration to examine the performance parameters. Sensitivity, quality factor, full width at half maximum, and detection accuracy have all been numerically evaluated and assessed concerning the performance of the proposed SPR biosensor. The numerical investigation reveals the proposed biosensor structure has a much better sensitivity than the conventional structure. It has been found that by optimizing the structure with two metallic silver layers of 50 nm and 10 nm thickness, five layers of MoS2 (each of 0.4 nm), and a monolayer of BaTiO3 (5 nm), attained the highest sensitivity is 446 degree/RIU. The findings will pave the way for a novel heterostructure-based SPR biosensor for gas and biological sensing in the visible region.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] Numerical analysis of a Kretschmann surface plasmon resonance sensor with silver/TiO2/BaTiO3/silver/graphene for refractive index sensing
    Zain, Huda A.
    Batumalay, Malathy
    Rahim, Hazli R. A.
    Harun, Sulaiman Wadi
    [J]. OPTOELECTRONICS LETTERS, 2023, 19 (10) : 583 - 586
  • [12] Numerical Study of 2D Nanomaterial-Based Surface Plasmon Resonance Biosensor
    Jaiswal, Laxmi
    Dwivedi, D. K.
    Lohia, Pooja
    Mishra, Adarsh Chandra
    Yadav, Sapana
    Yadav, R. K.
    [J]. PLASMONICS, 2024, 19 (06) : 3287 - 3297
  • [13] WS2-CH3NH3PbI3 Perovskite Nanostructure based Bimetallic Surface Plasmon Resonance Biosensor with High Sensitivity and High Resolution
    Miah, Mohammad Abu Raihan
    Shaikh, Al-Amin
    [J]. 2019 JOINT 8TH INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION (ICIEV) AND 2019 3RD INTERNATIONAL CONFERENCE ON IMAGING, VISION & PATTERN RECOGNITION (ICIVPR) WITH INTERNATIONAL CONFERENCE ON ACTIVITY AND BEHAVIOR COMPUTING (ABC), 2019, : 234 - 237
  • [14] Simulation of a Surface Plasmon Resonance Biosensor Using a Combination of TiO2 and 2D Materials for Blood Glucose Detection
    Kouhi, Mohammad
    [J]. PLASMONICS, 2025,
  • [15] Sensitivity enhancement of surface plasmon resonance sensor using Al-Au-BaTiO3-Graphene layers
    Suresh, N. Veerabagu
    Rajesh, K. B.
    Pillai, T. V. S.
    [J]. JOURNAL OF OPTICS-INDIA, 2021, 50 (02): : 152 - 159
  • [16] Sensitivity Improvement of Surface Plasmon Resonance Biosensors with GeS-Metal Layers
    Jia, Yue
    Liao, Yunlong
    Cai, Houzhi
    [J]. ELECTRONICS, 2022, 11 (03)
  • [17] High performance SPR biosensor using Cu-Pt bimetallic layers and 2D materials
    Maheswari, P.
    Ravi, V.
    Rajesh, K. B.
    Rahman, S. M. H.
    Jha, R.
    [J]. DIGEST JOURNAL OF NANOMATERIALS AND BIOSTRUCTURES, 2023, 18 (01) : 221 - 234
  • [18] Sensitivity Enhancement of 2D Material-Based Surface Plasmon Resonance Sensor with an Al-Ni Bimetallic Structure
    Hu, Miaosen
    Li, Min
    Li, Ming-Yu
    Wen, Xiaoyan
    Deng, Shuo
    Liu, Sisi
    Lu, Haifei
    [J]. SENSORS, 2023, 23 (03)
  • [19] Sensitivity enhancement of SPR biosensors employing heterostructure of PtSe2 and 2D materials
    Rahman, Md Mahabubur
    Rana, Md Masud
    Rahman, Md Saifur
    Anower, M. S.
    Mollah, Md Aslam
    Paul, Alok Kumar
    [J]. OPTICAL MATERIALS, 2020, 107
  • [20] Advancing Sensitivity in Guided-Wave Surface Plasmon Resonance Sensor through Integration of 2D BlueP/MoS2 Hybrid Layers
    Yuan, Xixi
    Wu, Leiming
    Qin, Yuwen
    [J]. BIOSENSORS-BASEL, 2024, 14 (01):