Impact of superconducting fault current limiters on Delayed Current Zeros in industrial power systems

被引:8
|
作者
Silva, R. F. [1 ]
Mafra, G. R. F. Q. [2 ]
Sotelo, G. G. [1 ]
Fortes, M. Z. [1 ]
Trillaud, F. [3 ]
Guillen, D. [4 ]
机构
[1] Fluminense Fed Univ UFF, Engn Sch, Passo Patria Str, 156, Room E347, BR-21240210 Niteroi, RJ, Brazil
[2] Petrobras SA, Republ Chile Str, 65, BR-20031912 Rio De Janeiro, RJ, Brazil
[3] Univ Nacl Autonoma Mexico, Inst Engn, Mexico City 04510, Mexico
[4] Tecnol Monterrey, Sch Engn & Sci, Monterrey 64849, Mexico
关键词
Superconductor fault current limiter; Delayed Current Zero; Vacuum circuit-breaker; Industrial power system; CIRCUIT-BREAKER; SIMULATIONS; PERFORMANCE;
D O I
10.1016/j.ijepes.2022.108594
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electric power systems may exhibit fault currents with high asymmetry when generators are close to large motors and loads. In this condition and depending on the fault inception instants, the fault current waveforms may present Delayed Current Zeros (DCZ). During transient studies, in some cases, breakers do not see the current zero-crossing for several cycles. Indeed, if the breaker opens just after a transient when the current has not reached steady-state and may be offset by a slow exponentially decaying DC component, then, the breaker will fail to open as the current will not cross zero within the interruption time. Here, the main concern associated with DCZ is however related to the interruption of the circuit breakers on a current wave crossing zero. At this moment, the interruption is accompanied of an electrical arc having the potential to damage equipment. Resistive superconducting fault current limiters (r-SFCL) are a known solution to reduce the magnitude of short-circuit current in electrical systems. It is a versatile technology that can tackle both fault and stability issues in aging and modern power grids alike. As a side benefit, it may also address the DCZ problem. The present work aims at investigating the impact that an r-SFCL may have on DCZ and, in particular, its ability to eliminate this issue altogether. To that end, a r-SFCL based on an existing design was modeled using the consolidated thermal-electrical analogy. This approach has proven to be fairly accurate to model the transient behavior of the superconducting device. Here, the case study simulates a solid short-circuit at the terminal of a generator in a specific bus, simulating an industrial power system, that includes a circuit breaker, a motor load, and a r-SFCL. The electromagnetic transient computations were carried out considering load and no-load conditions with and without the r-SFCL. Eight scenarios were considered, showing that r-SFCLs can actually address DCZ in addition to limit the fault level.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Practical application issues of superconducting fault current limiters for electric power systems
    Lee, B. W.
    Sim, J.
    Park, K. B.
    Oh, I. S.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 620 - 623
  • [12] Development of superconducting fault current limiters
    Xin, Ying
    Gong, Weizhi
    Niu, Xiaoye
    Cao, Zhengjian
    Xi, Haixia
    Zhang, Jingyin
    Wang, Yang
    Tian, Bo
    Hou, Bo
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 569 - +
  • [13] Impact on Superconducting Fault Current Limiters on Circuit Breaker Capability
    Bahirat, H. J.
    Khaparde, S. A.
    Kodle, S.
    Dabeer, V.
    2016 NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2016,
  • [14] Impact of the superconducting fault current limiters in distribution network architecture
    Gandioli, Camille
    Tixador, Pascal
    Alvarez-Herault, Marie-Cecile
    Hadjsaid, Nouredine
    2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [15] Analysis of unsymmetrical faults in high voltage power systems with superconducting fault current limiters
    Stemmle, Mark
    Neumann, Claus
    Merschel, Frank
    Schwing, Ulrich
    Weck, Karl-Heinz
    Noe, Mathias
    Breuer, Frank
    Elschner, Steffen
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 2347 - 2350
  • [16] Impacts of Superconducting Fault Current Limiters on the Recloser Operation in Distribution Electric Power Systems
    Rhee, S. B.
    Lee, J. K.
    Lee, B. W.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 2197 - 2200
  • [17] Power quality, micro superconducting magnetic energy storage systems, and fault current limiters
    Parizh, M
    APPLICATIONS OF SUPERCONDUCTIVITY, 1999, 365 : 415 - 455
  • [18] Fault Current Limiters in Power Systems: A Comprehensive Review
    Alam, Md Shafiul
    Abido, Mohammad Ali Yousef
    El-Amin, Ibrahim
    ENERGIES, 2018, 11 (05)
  • [19] Analysis on the impact of HTS cables and fault-current limiters on power systems
    Martini, LE
    Bigoni, L
    Cappai, G
    Iorio, R
    Malgarotti, S
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 1818 - 1821
  • [20] Power Differential Protection for Transmission Lines with Superconducting Fault Current Limiters
    Mansour, Diaa-Eldin A.
    Ahmed, Eman S.
    2019 21ST INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON 2019), 2019, : 337 - 341