Influence of reconstruction techniques on PET/CT image quality and quantitative accuracy: a phantom study

被引:1
作者
Su, Xuesong [1 ]
Geng, Jianhua [1 ]
Liu, Jianing [1 ]
Liu, Fengshuo [1 ]
Wu, Yichen [1 ]
Zheng, Rong [1 ]
Wang, Xuejuan [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Canc Hosp, Dept Nucl Med, Natl Canc Ctr,Natl Clin Res Ctr Canc, Beijing 100021, Peoples R China
关键词
Positron emission tomography (PET); Image quality; Quantification accuracy; Reconstruction techniques; Phantom; TIME-OF-FLIGHT; POINT-SPREAD-FUNCTION; PHYSICAL FIGURES; PERFORMANCE; RESOLUTION; IMPACT; ALGORITHMS; NOISE; MERIT; OSEM;
D O I
10.1007/s41605-023-00441-w
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
PurposeTo investigate the influence of different reconstruction techniques on the quantitative accuracy and image quality of PET/CT.MethodsThe NEMA NU2-2018 image quality phantom was scanned on a GE Discovery Elite PET/CT scanner and the spatial resolution was measured based on NEMA NU2 standard. The same raw data were reconstructed using five different algorithms: ordered subset expectation maximization (OSEM), OSEM with point spread function (PSF) modeling, OSEM with time-of-flight (TOF), OSEM with TOF and PSF, and filtered back-projection (FBP). The recovery coefficient (RC), contrast recovery coefficient (CRC), and contrast-to-noise ratio (CNR) were calculated for the six hot spheres, the percent background variability (PBV) and coefficient of variation (COV) were calculated for the background, and the residual error (RE) was calculated for lung insert in different image slices.ResultsThe incorporation of PSF modeling showed the smallest transverse FWHM and FWTM at both 1 and 10 cm radical offsets. The combination of PSF modeling and TOF improved RCmean and CRC for all spheres and resulted in the highest ratings for the detectability of 10 mm spheres in human observer assessment. PSF modeling played a role in reducing the COV within the background region of interest and increasing the CNR of the spheres, and decreased background noise ratings in human observer assessment. Besides, TOF significantly reduced the RE in lung insert. Neither PSF modeling nor TOF had a significant effect on PBV. Compared to FBP, the OSEM algorithm showed significant advantages in PBV, COV, CNR and RE and human observer ratings of image quality, but worse results for RCmax, RCmean and CRC.ConclusionsThe integration of TOF and PSF modeling into the OSEM algorithm achieves improvements in both quantitative accuracy and image quality, providing distinct advantages. PSF modeling improves the spatial resolution and decreases the visual appearance of background noise. The OSEM algorithm shows significantly better image quality than the FBP algorithm but no distinct advantages concerning quantitative accuracy.
引用
收藏
页码:1171 / 1186
页数:16
相关论文
共 50 条
  • [21] Deep Learning Reconstruction at CT: Phantom Study of the Image Characteristics
    Higaki, Toru
    Nakamura, Yuko
    Zhou, Jian
    Yu, Zhou
    Nemoto, Takuya
    Tatsugami, Fuminari
    Awai, Kazuo
    ACADEMIC RADIOLOGY, 2020, 27 (01) : 82 - 87
  • [22] Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters
    Akamatsu, Go
    Ishikawa, Kaori
    Mitsumoto, Katsuhiko
    Taniguchi, Takafumi
    Ohya, Nobuyoshi
    Baba, Shingo
    Abe, Koichiro
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) : 1716 - 1722
  • [23] A NIM PET/CT phantom for evaluating the PET image quality of micro-lesions and the performance parameters of CT
    Shujie Lu
    Peng Zhang
    Chengwei Li
    Jie Sun
    Wenli Liu
    Pu Zhang
    BMC Medical Imaging, 21
  • [24] Impact of PET/CT image reconstruction methods and liver uptake normalization strategies on quantitative image analysis
    Kuhnert, Georg
    Boellaard, Ronald
    Sterzer, Sergej
    Kahraman, Deniz
    Scheffler, Matthias
    Wolf, Juergen
    Dietlein, Markus
    Drzezga, Alexander
    Kobe, Carsten
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (02) : 249 - 258
  • [25] Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study
    Yang, Ching-Ching
    Liu, Shu-Hsin
    Mok, Greta S. P.
    Wu, Tung-Hsin
    MEDICAL PHYSICS, 2014, 41 (09)
  • [26] Impact of deep learning reconstructions on image quality and liver lesion detectability in dual-energy CT: An anthropomorphic phantom study
    Pauthe, Aurelie
    Milliner, Milan
    Pasquier, Hugo
    Campagnolo, Lucie
    Mule, Sebastien
    Luciani, Alain
    MEDICAL PHYSICS, 2025, : 2257 - 2268
  • [27] TOF-PET Small-Lesion Image Quality Measured Over a Range of Phantom Sizes
    Wilson, Joshua M.
    Turkington, Timothy G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) : 1589 - 1595
  • [28] Impact of reconstruction algorithms at different sphere-to-background ratios on PET quantification: A phantom study
    Mohymen, Ahmed A.
    Farag, Hamed I.
    Reda, Sameh M.
    Monem, Ahmed S.
    Ali, Said A.
    APPLIED RADIATION AND ISOTOPES, 2025, 220
  • [29] Impact of deep learning image reconstruction on volumetric accuracy and image quality of pulmonary nodules with different morphologies in low-dose CT
    D'hondt, L.
    Franck, C.
    Kellens, P-j.
    Zanca, F.
    Buytaert, D.
    Van Hoyweghen, A.
    El Addouli, H.
    Carpentier, K.
    Niekel, M.
    Spinhoven, M.
    Bacher, K.
    Snoeckx, A.
    CANCER IMAGING, 2024, 24 (01)
  • [30] PET IMAGE QUALITY ASSURANCE WITH MADEIRA PHANTOM
    Chipiga, Larisa
    Zvonova, Irina
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 111 - 114