Amplifying the Effects of Contrast Agents on Magnetic Resonance Images Using a Deep Learning Method Trained on Synthetic Data

被引:13
作者
Fringuello Mingo, Alberto [1 ]
Colombo Serra, Sonia [1 ]
Macula, Anna [2 ]
Bella, Davide [1 ]
La Cava, Francesca [1 ]
Ali, Marco [1 ,3 ]
Papa, Sergio [3 ]
Tedoldi, Fabio [1 ]
Smits, Marion [4 ,5 ]
Bifone, Angelo [2 ]
Valbusa, Giovanni [1 ,6 ]
机构
[1] Bracco Imaging Spa, Milan, Italy
[2] Univ Torino, Turin, Italy
[3] Ctr Diagnost Italiano, Milan, Italy
[4] Erasmus Univ, Dept Radiol & Nucl Med, Med Ctr Rotterdam, Rotterdam, Netherlands
[5] Med Delta, Delft, Netherlands
[6] Bracco Imaging Spa, Via Ribes 5, I-10010 Turin, Italy
关键词
diagnostic imaging; deep learning; amplification of image enhancement; contrast media; novel deep learning training strategy; synthetic data; MULTIPLE-SCLEROSIS; MRI; STANDARD; REDUCTION; LESIONS; TRACER; BLOOD; DTPA;
D O I
10.1097/RLI.0000000000000998
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesArtificial intelligence (AI) methods can be applied to enhance contrast in diagnostic images beyond that attainable with the standard doses of contrast agents (CAs) normally used in the clinic, thus potentially increasing diagnostic power and sensitivity. Deep learning-based AI relies on training data sets, which should be sufficiently large and diverse to effectively adjust network parameters, avoid biases, and enable generalization of the outcome. However, large sets of diagnostic images acquired at doses of CA outside the standard-of-care are not commonly available. Here, we propose a method to generate synthetic data sets to train an "AI agent" designed to amplify the effects of CAs in magnetic resonance (MR) images. The method was fine-tuned and validated in a preclinical study in a murine model of brain glioma, and extended to a large, retrospective clinical human data set.Materials and MethodsA physical model was applied to simulate different levels of MR contrast from a gadolinium-based CA. The simulated data were used to train a neural network that predicts image contrast at higher doses. A preclinical MR study at multiple CA doses in a rat model of glioma was performed to tune model parameters and to assess fidelity of the virtual contrast images against ground-truth MR and histological data. Two different scanners (3 T and 7 T, respectively) were used to assess the effects of field strength. The approach was then applied to a retrospective clinical study comprising 1990 examinations in patients affected by a variety of brain diseases, including glioma, multiple sclerosis, and metastatic cancer. Images were evaluated in terms of contrast-to-noise ratio and lesion-to-brain ratio, and qualitative scores.ResultsIn the preclinical study, virtual double-dose images showed high degrees of similarity to experimental double-dose images for both peak signal-to-noise ratio and structural similarity index (29.49 dB and 0.914 dB at 7 T, respectively, and 31.32 dB and 0.942 dB at 3 T) and significant improvement over standard contrast dose (ie, 0.1 mmol Gd/kg) images at both field strengths. In the clinical study, contrast-to-noise ratio and lesion-to-brain ratio increased by an average 155% and 34% in virtual contrast images compared with standard-dose images. Blind scoring of AI-enhanced images by 2 neuroradiologists showed significantly better sensitivity to small brain lesions compared with standard-dose images (4.46/5 vs 3.51/5).ConclusionsSynthetic data generated by a physical model of contrast enhancement provided effective training for a deep learning model for contrast amplification. Contrast above that attainable at standard doses of gadolinium-based CA can be generated through this approach, with significant advantages in the detection of small low-enhancing brain lesions.
引用
收藏
页码:853 / 864
页数:12
相关论文
共 54 条
[1]  
[Anonymous], 2002, Guidance Document on the Recognition, Assessment and Use of Clinical Signs as Human Endpoints for Experimental Animals Used in Safety Evaluation, DOI DOI 10.1787/9789264078376-EN
[2]   A method for machine learning generation of realistic synthetic datasets for validating healthcare applications [J].
Arvanitis, Theodoros N. ;
White, Sean ;
Harrison, Stuart ;
Chaplin, Rupert ;
Despotou, George .
HEALTH INFORMATICS JOURNAL, 2022, 28 (02)
[3]   Post-contrast 3D T1-weighted TSE MR sequences (SPACE, CUBE, VISTA/BRAINVIEW, isoFSE, 3D MVOX): Technical aspects and clinical applications [J].
Bapst, Blanche ;
Amegnizin, Jean-Louis ;
Vignaud, Alexandre ;
Kauv, Paul ;
Maraval, Anne ;
Kalsoum, Erwah ;
Tuilier, Titien ;
Benaissa, Azzedine ;
Brugieres, Pierre ;
Leclerc, Xavier ;
Hodel, Jerome .
JOURNAL OF NEURORADIOLOGY, 2020, 47 (05) :360-370
[4]   From Dose Reduction to Contrast Maximization Can Deep Learning Amplify the Impact of Contrast Media on Brain Magnetic Resonance Image Quality? A Reader Study [J].
Bone, Alexandre ;
Ammari, Samy ;
Menu, Yves ;
Balleyguier, Corinne ;
Moulton, Eric ;
Chouzenoux, Emilie ;
Volk, Andreas ;
Garcia, Gabriel C. T. E. ;
Nicolas, Francois ;
Robert, Philippe ;
Rohe, Marc-Michel ;
Lassau, Nathalie .
INVESTIGATIVE RADIOLOGY, 2022, 57 (08) :527-535
[5]  
Chaudhary Vikas, 2011, Indian J Endocrinol Metab, V15 Suppl 3, pS216, DOI 10.4103/2230-8210.84871
[6]   Synthetic data in machine learning for medicine and healthcare [J].
Chen, Richard J. ;
Lu, Ming Y. ;
Chen, Tiffany Y. ;
Williamson, Drew F. K. ;
Mahmood, Faisal .
NATURE BIOMEDICAL ENGINEERING, 2021, 5 (06) :493-497
[7]   Detecting Response of Rat C6 Glioma Tumors to Radiotherapy Using Hyperpolarized [1-13C]Pyruvate and 13C Magnetic Resonance Spectroscopic Imaging [J].
Day, Sam E. ;
Kettunen, Mikko I. ;
Cherukuri, Murali Krishna ;
Mitchell, James B. ;
Lizak, Martin J. ;
Morris, H. Douglas ;
Matsumoto, Shingo ;
Koretsky, Alan P. ;
Brindle, Kevin M. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) :557-563
[8]   Sensitivity of different MRI sequences in the early detection of melanoma brain metastases [J].
Deike-Hofmann, Katerina ;
Thuenemann, Daniel ;
Breckwoldt, Michael O. ;
Schwarz, Daniel ;
Radbruch, Alexander ;
Enk, Alexander ;
Bendszus, Martin ;
Hassel, Jessica ;
Schlemmer, Heinz-Peter ;
Baeumer, Philipp .
PLOS ONE, 2018, 13 (03)
[9]   Optimizing intracranial metastasis detection for stereotactic radiosurgery [J].
Engh, Johnathan A. ;
Flickinger, John C. ;
Niranjan, Ajay ;
Amin, Devin V. ;
Kondziolka, Douglas S. ;
Lunsford, L. Dade .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2007, 85 (04) :162-168
[10]   Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS [J].
Filippi, M ;
Yousry, T ;
Campi, A ;
Kandziora, C ;
Colombo, B ;
Voltz, R ;
Martinelli, V ;
Spuler, S ;
Bressi, S ;
Scotti, G ;
Comi, G .
NEUROLOGY, 1996, 46 (02) :379-384