Rapid determination of malondialdehyde in serum samples using a porphyrin-functionalized magnetic graphene oxide electrochemical sensor

被引:6
作者
Ben Attig, Jihene [1 ,2 ,3 ]
Latrous, Latifa [4 ]
Galvan, Ismael [5 ]
Zougagh, Mohammed [2 ,6 ]
Rios, Angel [1 ,2 ]
机构
[1] Univ Castilla La Mancha, Dept Analyt Chem & Food Technol, Fac Chem Sci & Technol, Campus Univ, Ciudad Real 13071, Spain
[2] IRICA, Reg Inst Appl Sci Res, Camilo Jose Cela Ave, E-13005 Ciudad Real, Spain
[3] Univ Tunis El Manar, Lab Chim Analyt & Elect Chim, Fac Sci Tunis, Dept Chem, Univ Campus El Manar II, Tunis 2092, Tunisia
[4] Univ Tunis El Manar, Lab Chim Minerale Appl, Fac Sci Tunis, Dept Chem, Univ Campus El Manar II, Tunis 2092, Tunisia
[5] CSIC, Natl Museum Nat Sci, Dept Evolutionary Ecol, Madrid 28006, Spain
[6] Univ Castilla La Mancha, Fac Pharm, Dept Analyt Chem & Food Technol, Albacete 02071, Spain
关键词
Porphyrin-functionalized magnetic graphene oxide; Screen-printed carbon electrode; Electrochemical sensor; Malondialdehyde; Serum samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; THIOBARBITURIC ACID REACTION; SOLID-PHASE EXTRACTION; HUMAN PLASMA; LABEL-FREE; GAS-CHROMATOGRAPHY; DERIVATIZATION; DOPAMINE; BIOSENSORS; SURFACE;
D O I
10.1007/s00216-023-04594-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electrochemical sensor based on a screen-printed carbon electrode (SPCE) modified with porphyrin-functionalized magnetic graphene oxide (TCPP-MGO) was developed for the sensitive and selective determination of malondialdehyde (MDA), an important biomarker of oxidative damage, in serum samples. The coupling of TCPP with MGO allows the exploitation of the magnetic properties of the material for separation, preconcentration, and manipulation of analyte, which is selectively captured onto the TCPP-MGO surface. The electron-transfer capability in the SPCE was improved through derivatization of MDA with diaminonaphthalene (DAN) (MDA-DAN). TCPP-MGO-SPCEs have been employed to monitor the differential pulse voltammetry (DVP) levels of the whole material, which is related to the amount of the captured analyte. Under optimum conditions, the nanocomposite-based sensing system has proved to be suitable for the monitoring of MDA, presenting a wide linear range (0.01-100 mu M) with a correlation coefficient of 0.9996. The practical limit of quantification (P-LOQ) of the analyte was 0.010 mu M, and the relative standard deviation (RSD) was 6.87% for 30 mu M MDA concentration. Finally, the developed electrochemical sensor has demonstrated to be adequate for bioanalytical applications, presenting an excellent analytical performance for the routine monitoring of MDA in serum samples.
引用
收藏
页码:2071 / 2080
页数:10
相关论文
共 40 条
[31]   Volatile aldehydes sensing in headspace using a room temperature ionic liquid-modified electrochemical microprobe [J].
Toniolo, Rosanna ;
Dossi, Nicolo ;
Bortolomeazzi, Renzo ;
Bonazza, Gregorio ;
Daniele, Salvatore .
TALANTA, 2019, 197 :522-529
[32]   Biosensors based on screen-printing technology, and their applications in environmental and food analysis [J].
Tudorache, Madalina ;
Bala, Camelia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (03) :565-578
[33]   Label-Free Ultrasensitive Detection of Human Telomerase Activity Using Porphyrin-Functionalized Graphene and Electrochemiluminescence Technique [J].
Wu, Li ;
Wang, Jiasi ;
Feng, Lingyan ;
Ren, Jinsong ;
Wei, Weili ;
Qu, Xiaogang .
ADVANCED MATERIALS, 2012, 24 (18) :2447-2452
[34]   Electrochemical detection of dopamine using porphyrin-functionalized graphene [J].
Wu, Li ;
Feng, Lingyan ;
Ren, Jinsong ;
Qu, Xiaogang .
BIOSENSORS & BIOELECTRONICS, 2012, 34 (01) :57-62
[35]   A rapid spectrofluorimetric method for the determination of malondialdehyde in human plasma after its derivatization with thiobarbituric acid and vortex assisted liquid-liquid microextraction [J].
Yahyavi, Hossain ;
Kaykhaii, Massoud ;
Hashemi, Mohammad .
RSC ADVANCES, 2016, 6 (03) :2361-2367
[36]   Label-free and facile electrochemical biosensing using carbon nanotubes for malondialdehyde detection [J].
Yuan, Ling ;
Lan, Yaqian ;
Han, Min ;
Bao, Jianchun ;
Tu, Wenwen ;
Dai, Zhihui .
ANALYST, 2013, 138 (11) :3131-3134
[37]   Electrodeposition of taurine on gold surface and electro-oxidation of malondialdehyde [J].
Zamani-Kalajahi, M. ;
Hasanzadeh, M. ;
Shadjou, N. ;
Khoubnasabjafari, M. ;
Ansarin, K. ;
Jouyban-Gharamaleki, V. ;
Jouyban, A. .
SURFACE ENGINEERING, 2015, 31 (03) :194-201
[38]   Ultrasensitive detection of malondialdehyde with surface-enhanced Raman spectroscopy [J].
Zhang, Dongmao ;
Haputhanthri, Rukshani ;
Ansar, Siyam M. ;
Vangala, Karthikeshwar ;
De Silva, Hondamuni I. ;
Sygula, Andrzej ;
Saebo, Svein ;
Pittman, Charles U., Jr. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (7-8) :3193-3201
[39]   Porphyrin functionalized graphene nanosheets-based electrochemical aptasensor for label-free ATP detection [J].
Zhang, Hongfen ;
Han, Yujie ;
Guo, Yujing ;
Dong, Chuan .
JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (45) :23900-23905
[40]  