Comparison of the rehabilitation of posterior atrophic edentulous mandible with different interforaminal implant placement concepts: a 3D finite element analysis

被引:3
|
作者
Akca, B. S. [1 ]
Kucukkurt, S. [1 ]
机构
[1] Istanbul Aydin Univ, Dept Oral & Maxillofacial Surg, Istanbul, Turkiye
关键词
biomechanics; dental implants; implant-supported; dental prosthesis; finite element analysis; mandible; mental; foramen; alveolar bone atrophy; dental stress analysis; STRESS-DISTRIBUTION; ALL-ON-4; IMPLANTS; FIXED PROSTHESIS; CONFIGURATIONS; RESTORATIONS; MAXILLARY; DIAMETER; SUPPORT; DESIGNS; REGION;
D O I
10.23805/JO.2023.560
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The study aims to compare the rehabilitation of the posterior atrophic edentulous mandible with different interforaminal implant placement concepts to apply an implant-supported fixed prosthesis, without needing any bone grafting procedure.Material and methods Six models were created in a digital environment. Three, four, and five implants were vertically placed in different models; the Nobel Trefoil concept, the All on-3, and the All-on-4 concepts were also simulated. In the Trefoil model, implants specific to this concept were used. In all models, the prosthetic emergence of posterior implants was simulated at the same point. Screw-retained fixed prostheses were placed on the implants. A spherical foodstuff force was applied to imitate the chewing forces from the canine and molar regions. The three-dimensional finite element method analyzed the stresses on bones, implants, and prosthetic structures.Results The most balanced stress distribution was seen in the Trefoil concept, while the worst stresses were observed in the All-on-3. The stress obtained in the models with four and five vertical implants was very close. Increasing the number of implants slightly affected stress, however, reducing the number to three, significantly increased the stress. Inclined placement of the same number of implants increased stresses on bone.Conclusions With its unique implants, the trefoil concept emerged as the optimal treatment option for fixed prosthetic restoration in the interforaminal area. The best option among the models with standard diameter implants is four vertical implants. Inclined placement of posterior implants did not reduce stresses. On the contrary, it increased stresses, unless the emergence profile was moved posteriorly or the implant lengths were increased.
引用
收藏
页码:155 / 164
页数:10
相关论文
共 50 条
  • [21] Extrasinus Zygomatic Implant Placement in the Rehabilitation of the Atrophic Maxilla: Three-Dimensional Finite Element Stress Analysis
    Romeed, Shihab A.
    Hays, Robert Nigel
    Malik, Raheel
    Dunne, Stephen M.
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (02) : E1 - E6
  • [22] Optimum selection of the dental implant diameter and length in the posterior mandible with poor bone quality - A 3D finite element analysis
    Li, Tao
    Hu, Kaijin
    Cheng, Libo
    Ding, Yin
    Ding, Yuxiang
    Shao, Jinling
    Kong, Liang
    APPLIED MATHEMATICAL MODELLING, 2011, 35 (01) : 446 - 456
  • [23] Finite Element Stress Analysis of Edentulous Mandibles with Different Bone Types Supporting Multiple-Implant Superstructures
    de Almeida, Erika Oliveira
    Rocha, Eduardo Passos
    Freitas, Amilcar Chagas, Jr.
    Martin, Manoel, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (06) : 1108 - 1114
  • [24] Stress evaluation of different implant lengths on atrophic edentulous mandibles with fixed full-arch implant-supported prosthesis: a finite element analysis
    Benevides, Fernanda
    Cimoes, Renata
    Vajgel, Andre
    Wilmersdorf, Ramiro Brito
    Farias Vajgel, Bruna de Carvalho
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (04) : 358 - 374
  • [25] Evaluation of treatment options for atrophic mandible under trauma forces: a 3D finite element analysis treatment options for atrophic mandible under trauma forces
    İpek Dilara Baş
    Emre Tosun
    Ilgın Ari
    Gülin Acar
    BMC Oral Health, 25 (1)
  • [26] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Oğuz Eraslan
    Özgür İnan
    Clinical Oral Investigations, 2010, 14 : 411 - 416
  • [27] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Eraslan, Oguz
    Inan, Oezguer
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 411 - 416
  • [28] Can the modeling for simplification of a dental implant surface affect the accuracy of 3D finite element analysis?
    Verri, Fellippo Ramos
    Cruz, Ronaldo Silva
    de Souza Batista, Victor Eduardo
    de Faria Almeida, Daniel Augusto
    Goncales Verri, Ana Caroline
    de Araujo Lemos, Cleidiel Aparecido
    Santiago Junior, Joel Ferreira
    Pellizzer, Eduardo Piza
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (15) : 1665 - 1672
  • [29] Biomechanical Analysis of Different Framework Design, Framework Material and Bone Density in the Edentulous Mandible With Fixed Implant-Supported Prostheses: A Three-Dimensional Finite Element Study
    Yu, Wenqian
    Chen, Siyi
    Ma, Li
    Ma, Xiaoni
    Xu, Xin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (04): : 309 - 317
  • [30] Effect of angled abutments in the posterior maxillary region on tilted implants: a 3D finite element analysis
    Chen, Peng
    Zhang, Jianguo
    Yao, Juan
    Hu, Fengling
    Song, Liang
    Yu, Youcheng
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (08) : 2585 - 2597