Comparison of the rehabilitation of posterior atrophic edentulous mandible with different interforaminal implant placement concepts: a 3D finite element analysis

被引:3
|
作者
Akca, B. S. [1 ]
Kucukkurt, S. [1 ]
机构
[1] Istanbul Aydin Univ, Dept Oral & Maxillofacial Surg, Istanbul, Turkiye
关键词
biomechanics; dental implants; implant-supported; dental prosthesis; finite element analysis; mandible; mental; foramen; alveolar bone atrophy; dental stress analysis; STRESS-DISTRIBUTION; ALL-ON-4; IMPLANTS; FIXED PROSTHESIS; CONFIGURATIONS; RESTORATIONS; MAXILLARY; DIAMETER; SUPPORT; DESIGNS; REGION;
D O I
10.23805/JO.2023.560
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The study aims to compare the rehabilitation of the posterior atrophic edentulous mandible with different interforaminal implant placement concepts to apply an implant-supported fixed prosthesis, without needing any bone grafting procedure.Material and methods Six models were created in a digital environment. Three, four, and five implants were vertically placed in different models; the Nobel Trefoil concept, the All on-3, and the All-on-4 concepts were also simulated. In the Trefoil model, implants specific to this concept were used. In all models, the prosthetic emergence of posterior implants was simulated at the same point. Screw-retained fixed prostheses were placed on the implants. A spherical foodstuff force was applied to imitate the chewing forces from the canine and molar regions. The three-dimensional finite element method analyzed the stresses on bones, implants, and prosthetic structures.Results The most balanced stress distribution was seen in the Trefoil concept, while the worst stresses were observed in the All-on-3. The stress obtained in the models with four and five vertical implants was very close. Increasing the number of implants slightly affected stress, however, reducing the number to three, significantly increased the stress. Inclined placement of the same number of implants increased stresses on bone.Conclusions With its unique implants, the trefoil concept emerged as the optimal treatment option for fixed prosthetic restoration in the interforaminal area. The best option among the models with standard diameter implants is four vertical implants. Inclined placement of posterior implants did not reduce stresses. On the contrary, it increased stresses, unless the emergence profile was moved posteriorly or the implant lengths were increased.
引用
收藏
页码:155 / 164
页数:10
相关论文
共 50 条
  • [1] Is it beneficial to support interforaminal implant placement techniques with ultra-short implants in the posterior region? A 3D finite element analysis
    Kucukkurt, S.
    Konuklu, R.
    Celikkol, S.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (02) : 95 - 104
  • [2] Comparison of Four Implant-Supported Fixed Rehabilitation Options of the Edentulous Mandible: A 3D Finite Element Analysis
    Kucukkurt, Sercan
    Tukel, Huseyin Can
    JOURNAL OF ADVANCED ORAL RESEARCH, 2020, 11 (01) : 57 - 64
  • [3] Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
    Ayali, Aysa
    Bilginaylar, Kani
    HEAD & FACE MEDICINE, 2017, 13
  • [4] The effect of frontal trauma on the edentulous mandible with four different interforaminal implant-prosthodontic anchoring configurations. A 3D finite element analysis
    Stefan, Krennmair
    Michael, Malek
    Raphael, Stehrer
    Staehler, Philip
    Sven, Otto
    Lukas, Postl
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [5] Rehabilitation of Atrophic Posterior Maxilla with Pterygoid Implants: A 3D Finite Element Analysis
    Wilkirson, Elizabeth
    Chandran, Ravi
    Duan, Yuanyuan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : E51 - E62
  • [6] Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
    Aysa Ayali
    Kani Bilginaylar
    Head & Face Medicine, 13
  • [7] Biomechanical Effects of Different Load Cases with an Implant-Supported Full Bridge on Four Implants in an Edentulous Mandible: A Three-Dimensional Finite Element Analysis (3D-FEA)
    Szabo, arpad Laszlo
    Matusovits, Danica
    Slyteen, Haydar
    Lakatos, eva Ilona
    Barath, Zoltan
    Schmidlin, Patrick R.
    DENTISTRY JOURNAL, 2023, 11 (11)
  • [8] Implant Rehabilitation of the Edentulous Posterior Atrophic Mandible: The Sandwich Osteotomy Revisited
    Luis Lopez-Cedrun, Jose
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) : 195 - 202
  • [9] Implant-Supported Prostheses in the Edentulous Mandible: Biomechanical Analysis of Different Implant Configurations via Finite Element Analysis
    Anitua, Eduardo
    de Ibarra, Naiara Larrazabal Saez
    Rotaeche, Luis Saracho
    DENTISTRY JOURNAL, 2023, 11 (01)
  • [10] Mechanical Influence of Edentulous Mandible Morphology on Peri-implant Bone in Implant Prosthetics: 3D Finite Element Analysis
    Hamada, Takumi
    Gonda, Tomoya
    Murase, Kohei
    Maeda, Yoshinobu
    Ikebe, Kazunori
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : 931 - 937