The Application of Membrane Bioreactor for Greywater Treatment

被引:2
作者
Fikri, Elanda [1 ,2 ]
Zulkarnain, Oryza Filial [3 ]
Azizah, R. [3 ]
Latif, Mohd Talib [4 ]
Firmansyah, Yura Witsqa [5 ]
机构
[1] Bandung Hlth Polytech, Environm Sanitat Dept, Pajajaran Str 56, Bandung 40171, Indonesia
[2] Bandung Hlth Polytech, Ctr Excellence Utilizat Local Mat Hlth Improvement, Bandung 40171, Indonesia
[3] Univ Airlangga, Fac Publ Hlth, Dept Environm Hlth, Airlangga Str 4-6, Surabaya City 60115, East Java, Indonesia
[4] Univ Kebangsaan Malaysia, Fac Sci & Technol, Dept Earth Sci & Environm, Bandar Baru Bangi St, Hulu Langat Dist 43600, Selangor, Malaysia
[5] Univ Sebelas Maret, Grad Sch, Doctoral Program Environm Sci, Ir Sutami St 36, Surakarta City 57126, Central Java, Indonesia
来源
JOURNAL OF ECOLOGICAL ENGINEERING | 2023年 / 24卷 / 06期
关键词
membrane bioreactor; wastewater; greywater; BOD; COD; total coliform; GREY WATER-TREATMENT; FOULING CONTROL; WASTE; MANAGEMENT; FLUX;
D O I
10.12911/22998993/162781
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Urban planning management should consider wastewater as a challenge. Wastewater, in this case, grey water, is full of dangerous contaminants and, at specific concentrations, can turn into a substance that affects the en-vironment. The effluent of the released waste must therefore be managed to ensure that it complies with the government's quality standard criteria. The membrane bioreactor (MBR) technology process produced waste effluents with low concentrations of biological oxygen demand (BOD5), chemical oxygen demand (COD), and total organic carbon (TOC), proving its higher efficiency as a biological processing stage. Total coliforms and E. coli are not present in processed products, detergents and total suspended solid (TSS) are effectively degraded. This is made possible by the considerably lower organic load; as a result, biomass accumulation slows and mixed liquor suspended solids (MLSS), which have low value, are produced. With the assistance of continuous airflow, and without the use of chemicals or backwashing, an ultrafiltration module (UF) with a membrane cut-off size small enough to be able to create a constant permeate flux during the grey water treatment process is necessary. Although processed grey water does not pass denitrification, all parameters linked to the quality of the effluent water exceed environmental quality criteria.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 34 条
  • [1] Abd. Aziz M. A., 2015, Malaysian Journal of Analytical Sciences, V19, P463
  • [2] Aditia A., 2020, J ILM MAKSITEK, V5, P5
  • [3] Afifah A.S., 2021, J SERAMBI ENG, P1762
  • [4] Al-Khafaji S.S., 2022, EURASIAN J ENG TECHN, V7, P98
  • [5] Asan Can, 2020, Konya Journal of Engineering Sciences, V8, P103, DOI 10.36306/konjes.698685
  • [6] Awaleh M. O., 2014, Hydrology: Current Research, V5, P164
  • [7] Banaszak J.E., 1998, ENVIRON PROG, V17, pS9
  • [8] Grey water treatment by a continuous process of an electrocoagulation unit and a submerged membrane bioreactor system
    Bani-Melhem, Khalid
    Smith, Edward
    [J]. CHEMICAL ENGINEERING JOURNAL, 2012, 198 : 201 - 210
  • [9] Membranes in water and wastewater disinfection - review
    Bodzek, Michal
    Konieczny, Krystyna
    Rajca, Mariola
    [J]. ARCHIVES OF ENVIRONMENTAL PROTECTION, 2019, 45 (01) : 3 - 18
  • [10] Membrane fouling in membrane bioreactors for wastewater treatment
    Chang, IS
    Le Clech, P
    Jefferson, B
    Judd, S
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2002, 128 (11) : 1018 - 1029