Palatal soft tissue thickness around dental implants and natural teeth in health and disease: A cross sectional study

被引:7
作者
Abu Hussien, Hiba [1 ]
Machtei, Eli E. [1 ,2 ]
Khutaba, Alaa [1 ]
Gabay, Eran [1 ,2 ]
Giladi, Hadar Zigdon [1 ,2 ,3 ]
机构
[1] Rambam Hlth Care Campus, Dept Periodontol, Sch Grad Dent, POB 9602, IL-31096 Haifa, Israel
[2] Technion Israeli Inst Technol, Fac Med, Haifa, Israel
[3] Rambam Hlth Care Campus, Lab Bone Repair, CRIR Inst, Haifa, Israel
关键词
mucosa phenotype; palate; peri-implantitis; periodontal pocket; SINGLE-TOOTH REPLACEMENTS; KERATINIZED MUCOSA WIDTH; AUGMENTATION PROCEDURES; CONSENSUS REPORT; INFLAMMATION; PERIIMPLANT; MAINTENANCE; IMPRESSION; STABILITY; WORKSHOP;
D O I
10.1111/cid.13171
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundPrevious studies focused on the influence of buccal mucosa thickness on peri-implant bone loss and inflammation, with inconclusive results. We observed substantially thicker palatal mucosal tissues at peri-implantitis sites. Therefore, we hypothesize that thick palatal peri-implant mucosa may be associated with deeper pockets and disease severity. PurposeTo compare the thickness of the palatal tissue between natural teeth and implants in periodontal health and disease. MethodsAdult, non-smoker, healthy patients who visited our department for periodontal examination or treatment with restored implants in the posterior maxilla were recruited. Probing depth (PD), plaque index (PI), gingival index (GI) and radiographic measurements were recorded around implant and the contralateral tooth. Palatal tissue thickness was measured using a 30G needle that was inserted perpendicular into the mucosa at the bottom of the periodontal/peri-implant pocket and 3 mm coronally. Differences in the palatal tissue thickness between teeth and implants (in the same patient) was performed using t-test; as well as between peri-implantitis and non-peri-implantitis sites (among patients). ResultsSixty patients were included. Thirty-four implants were diagnosed with peri-implantitis and 26 healthy/mucositis implants with corresponding 24 healthy/gingivitis teeth and 36 teeth with attachment loss. Mean PD was higher around implants (4.47 +/- 1.57 mm) than teeth (3.61 +/- 1.23 mm, p = 0.001). The thickness of implants' palatal mucosa was higher than in teeth, at the base of the pocket and 3 mm coronally (4.58 +/- 1.38 mm vs. 3.01 +/- 1.11, p = 0.000; 3.58 +/- 2.15 vs. 1.89 +/- 1.11, p = 0.000, respectively). Mean palatal tissue thickness was 4.32 +/- 2.35 mm for the peri-implantitis group while only 2.61 +/- 1.39 in healthy implants, 3 mm coronal to the base of the pocket (p = 0.001). Palatal thickness at peri-implantitis sites was higher (4.32 +/- 2.35) compared to periodontitis sites (2.23 +/- 0.93), p = 0.000. Implant sites with palatal mucosa >4 mm (n = 32) had deeper mean pockets (5.58 +/- 1.98) compared with thinner (<= 4 mm) sites (n = 28) (4.48 +/- 1.18, p = 0.018). ConclusionThicker palatal tissue around implants is associated with deeper palatal pockets. Thick palatal tissue was found around implants diagnosed with peri-implantitis.
引用
收藏
页码:215 / 223
页数:9
相关论文
共 45 条
[1]   Probe penetration in periodontal and peri-implant tissues: An experimental study in the beagle dog [J].
Abrahamsson, Ingemar ;
Soldini, Claudio .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (06) :601-605
[2]   Dimension of the periimplant mucosa - Biological width revisited [J].
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (10) :971-973
[3]   Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions [J].
Berglundh, Tord ;
Armitage, Gary ;
Araujo, Mauricio G. ;
Avila-Ortiz, Gustavo ;
Blanco, Juan ;
Camargo, Paulo M. ;
Chen, Stephen ;
Cochran, David ;
Derks, Jan ;
Figuero, Elena ;
Hammerle, Christoph H. F. ;
Heitz-Mayfield, Lisa J. A. ;
Guy Huynh-Ba ;
Iacono, Vincent ;
Koo, Ki-Tae ;
Lambert, France ;
McCauley, Laurie ;
Quirynen, Marc ;
Renvert, Stefan ;
Salvi, Giovanni E. ;
Schwarz, Frank ;
Tarnow, Dennis ;
Tomasi, Cristiano ;
Wang, Hom-Lay ;
Zitzmann, Nicola .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2018, 45 :S286-S291
[4]  
Bhat Pragathi Raghavendra, 2015, J Indian Soc Periodontol, V19, P640, DOI 10.4103/0972-124X.168489
[5]   Soft Tissue Response to Titanium Abutments with Different Surface Treatment: Preliminary Histologic Report of a Randomized Controlled Trial [J].
Canullo, Luigi ;
Dehner, Jan Friedrich ;
Penarrocha, David ;
Checchi, Vittorio ;
Mazzoni, Annalisa ;
Breschi, Lorenzo .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016
[6]   Tissue alterations at implant-supported single-tooth replacements:: a 1-year prospective clinical study [J].
Cardaropoli, G ;
Lekholm, U ;
Wennström, JL .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (02) :165-171
[7]   Implant supported single-tooth replacements compared to contralateral natural teeth -: Crown and soft tissue dimensions [J].
Chang, M ;
Wennström, JL ;
Ödman, P ;
Andersson, B .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (03) :185-194
[8]   Significance of keratinized mucosa in maintenance of dental implants with different surfaces [J].
Chung, Dyeus M. ;
Oh, Tae-Ju ;
Shotwell, Jeffrey L. ;
Misch, Carl E. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2006, 77 (08) :1410-1420
[9]   Influence of Soft Tissue Thickness on Peri-Implant Marginal Bone Loss: A Systematic Review and Meta-Analysis [J].
del Amo, Fernando Suarez-Lopez ;
Lin, Guo-Hao ;
Monje, Alberto ;
Galindo-Moreno, Pablo ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2016, 87 (06) :690-699
[10]   Ultrasonic Assessment of Mucosal Thickness around Implants: Validity, Reproducibility, and Stability of Connective Tissue Grafts at the Buccal Aspect [J].
Eghbali, Aryan ;
De Bruyn, Hugo ;
Cosyn, Jan ;
Kerckaert, Ingrid ;
Tom Van Hoof .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) :51-61