Are non-invasive estimations of plasma volume an accurate measure of congestion in patients with chronic heart failure?

被引:3
|
作者
Cuthbert, J. J. [1 ,2 ]
Pellicori, P. [3 ]
Rigby, A. S. [1 ]
Abel, A. A., I [1 ,2 ]
Kalvickbacka-Bennet, A. [1 ]
Shah, P. [1 ]
Kearsley, J. W. [1 ]
Kazmi, S. [1 ]
Cleland, J. G. F. [3 ]
Clark, A. L. [2 ]
机构
[1] Univ Hull, Ctr Clin Sci, Hull York Med Sch, Dept Cardioresp Med, Cottingham Rd, Kingston Upon Hull HU6 7RX, Yorks, England
[2] Hull Univ Hosp Trust, Dept Cardiol, Castle Hill Hosp, Castle Rd, Kingston Upon Hull HU16 5JQ, Yorks, England
[3] Univ Glasgow, Robertson Ctr Biostat, Glasgow Clin Trials Unit, Glasgow, Lanark, Scotland
关键词
Plasma volume; Congestion; Ultrasound; Heart failure; Anaemia; OUTCOMES;
D O I
10.1093/ehjqcco/qcac035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We report associations between different formulae for estimating plasma volume status (PVS) and clinical and ultrasound markers of congestion in patients with chronic heart failure (CHF) enrolled in the Hull Lifelab registry. Methods and results Cohort 1 comprised patients with data on signs and symptoms at initial evaluation (n = 3505). Cohort 2 included patients with ultrasound assessment of congestion [lung B-line count, inferior vena cava (IVC) diameter, jugular vein distensibility (JVD) ratio] (N = 341). Two formulae for PVS were used: (a) Hakim (HPVS) and (b) Duarte (DPVS). Results were compared with clinical and ultrasound markers of congestion. Outcomes assessed were mortality and the composite of heart failure (HF) hospitalisation and all-cause mortality. In cohort 1, HPVS was associated with mortality [hazard ratio (HR) per unitary increase = 1.02 (1.01-1.03); P < 0.001]. In cohort 2, HPVS was associated with B-line count (HR) = 1.05 [95% confidence interval (CI) (1.01-1.08); P = 0.02] and DPVS with the composite outcome [HR = 1.26 (1.01-1.58); P = 0.04]. HPVS and DPVS were strongly related to haemoglobin concentration and HPVS to weight. After multivariable analysis, there were no strong or consistent associations between PVS and measures of congestion, severity of symptoms, or outcome. By contrast, log[NTproBNP] was strongly associated with all three. Conclusion Amongst patients with CHF, HPVS and DPVS are not strongly or consistently associated with clinical or ultrasound evidence of congestion, nor clinical outcomes after multivariable adjustment. They appear only to be surrogates of the variables from which they are calculated with no intrinsic clinical utility.
引用
收藏
页码:281 / 292
页数:12
相关论文
共 50 条
  • [1] Estimated plasma volume is not a robust indicator of the severity of congestion in patients with heart failure
    Guvenc, Rengin Cetin
    Guvenc, Tolga Sinan
    Akil, Mehmet Ata
    Bekar, Lutfu
    Vural, Mustafa Gokhan
    Yilmaz, Mehmet Birhan
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2023, 366 (05) : 374 - 382
  • [2] Measuring congestion with a non-invasive monitoring device in heart failure and haemodialysis: CONGEST-HF
    Curtain, James P.
    Talebi, Atefeh
    McIntosh, Alasdair
    McConnachie, Alex
    O'Donnell, Joanne
    Welsh, Paul
    Osmanska, Joanna
    Lee, Matthew M. Y.
    Sonecki, Piotr
    Akl, Tony
    Seo, Joohyun
    Gopinathan, Venugopal
    Hurwitz, Jed
    Thiagarajan, Srikanth
    Pettit, Stephen
    Kalra, Paul R.
    Patel, Rajan K.
    Mark, Patrick B.
    Lang, Ninian N.
    McMurray, John J. V.
    Petrie, Mark C.
    Gardner, Roy S.
    Jhund, Pardeep S.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 (06) : 1383 - 1392
  • [3] Non-Invasive Assessment of Congestion by Cardiovascular and Pulmonary Ultrasound and Biomarkers in Heart Failure
    Iliesiu, Adriana Mihaela
    Hodorogea, Andreea Simona
    Balahura, Ana-Maria
    Badila, Elisabeta
    DIAGNOSTICS, 2022, 12 (04)
  • [4] Non-invasive measurement of cardiac output in patients with chronic heart failure
    Leslie, SJ
    McKee, S
    Newby, DE
    Webb, DJ
    Denvir, MA
    BLOOD PRESSURE MONITORING, 2004, 9 (05) : 277 - 280
  • [5] Non-invasive measurement of stroke volume during exercise in heart failure patients
    Agostoni, PG
    Wasserman, K
    Perego, GB
    Guazzi, M
    Cattadori, G
    Palermo, P
    Lauri, G
    Marenzi, G
    CLINICAL SCIENCE, 2000, 98 (05) : 545 - 551
  • [6] Comprehensive non-invasive evaluation of the functional status of patients with chronic heart failure
    Koloskova, N. N.
    Eyyubova, A. Q.
    Shevchenko, A. O.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2024, 26 (01): : 88 - 96
  • [7] Non-invasive estimation of stroke volume during exercise from oxygen in heart failure patients
    Accalai, Emanuele
    Vignati, Carlo
    Salvioni, Elisabetta
    Pezzuto, Beatrice
    Contini, Mauro
    Cadeddu, Christian
    Meloni, Luigi
    Agostoni, Piergiuseppe
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2021, 28 (03) : 280 - 286
  • [8] Non-invasive mechanical ventilation therapy in patients with heart failure
    Dursunoglu, Dursun
    Dursunoglu, Nese
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2012, 12 (03) : 261 - 268
  • [9] The role of non-invasive devices for the telemonitoring of heart failure patients
    A. Faragli
    D. Abawi
    C. Quinn
    M. Cvetkovic
    T. Schlabs
    E. Tahirovic
    H.-D. Düngen
    B. Pieske
    S. Kelle
    F. Edelmann
    Alessio Alogna
    Heart Failure Reviews, 2021, 26 : 1063 - 1080
  • [10] The role of non-invasive devices for the telemonitoring of heart failure patients
    Faragli, A.
    Abawi, D.
    Quinn, C.
    Cvetkovic, M.
    Schlabs, T.
    Tahirovic, E.
    Duengen, H. -D.
    Pieske, B.
    Kelle, S.
    Edelmann, F.
    Alogna, Alessio