关键词
Imaging; Elastography; Ultrasonic imaging; Acoustics; Phantoms; Frequency control; Elasticity; 3-D shear wave elastography (SWE); acoustic radiation force (ARF); comb-push shear elastography (CUSE); row-column addressing (RCA) array; ultrafast ultrasound imaging; LIVER FIBROSIS; WFUMB GUIDELINES; CLINICAL-USE; ULTRASOUND; ELASTICITY; RECOMMENDATIONS; TRACKING; MODE;
D O I
10.1109/TUFFC.2024.3366540
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Acoustic radiation force (ARF)-based shear wave elastography (SWE) is a clinically available ultrasound imaging mode that noninvasively and quantitatively measures tissue stiffness. Current implementations of ARF-SWE are largely limited to 2-D imaging, which does not provide a robust estimation of heterogeneous tissue mechanical properties. Existing 3-D ARF-SWE solutions that are clinically available are based on wobbler probes, which cannot provide true 3-D shear wave motion detection. Although 3-D ARF-SWE based on 2-D matrix arrays have been previously demonstrated, they do not provide a practical solution because of the need for a high channel-count ultrasound system (e.g., 1024-channel) to provide adequate volume rates and the delicate circuitries (e.g., multiplexers) that are vulnerable to the long-duration "push" pulses. To address these issues, here we propose a new 3-D ARF-SWE method based on the 2-D row-column addressing (RCA) array which has a much lower element count (e.g., 256), provides an ultrafast imaging volume rate (e.g., 2000 Hz), and can withstand the push pulses. In this study, we combined the comb-push shear elastography (CUSE) technique with 2-D RCA for enhanced SWE imaging field-of-view (FOV). In vitro phantom studies demonstrated that the proposed method had robust 3-D SWE performance in both homogenous and inclusion phantoms. An in vivo study on a breast cancer patient showed that the proposed method could reconstruct 3-D elasticity maps of the breast lesion, which was validated using a commercial ultrasound scanner. These results demonstrate strong potential for the proposed method to provide a viable and practical solution for clinical 3-D ARF-SWE.
引用
收藏
页码:448 / 458
页数:11
相关论文
共 48 条
[1]   WFUMB GUIDELINES AND RECOMMENDATIONS FOR CLINICAL USE OF ULTRASOUND ELASTOGRAPHY: PART 2: BREAST [J].
Barr, Richard G. ;
Nakashima, Kazutaka ;
Amy, Dominique ;
Cosgrove, David ;
Farrokh, Andre ;
Schafer, Fritz ;
Bamber, Jeffrey C. ;
Castera, Laurent ;
Choi, Byung Ihn ;
Chou, Yi-Hong ;
Dietrich, Christoph F. ;
Ding, Hong ;
Ferraioli, Giovanna ;
Filice, Carlo ;
Friedrich-Rust, Mireen ;
Hall, Timothy J. ;
Nightingale, Kathryn R. ;
Palmeri, Mark L. ;
Shiina, Tsuyoshi ;
Suzuki, Shinichi ;
Sporea, Ioan ;
Wilson, Stephanie ;
Kudo, Masatoshi .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05) :1148-1160
[2]   Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[3]  
Bernal M., 2021, PROC IEEE INT ULTRAS, P1
[4]  
Blaak S., 2009, 2009 IEEE International Ultrasonics Symposium, P1338, DOI 10.1109/ULTSYM.2009.5441534
[5]   Imaging Performance for Two Row-Column Arrays [J].
Bouzari, Hamed ;
Engholm, Mathias ;
Nikolov, Svetoslav Ivanov ;
Stuart, Matthias Bo ;
Thomsen, Erik Vilain ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (07) :1209-1221
[6]   Review of ultrasound elastography quality control and training test phantoms [J].
Cournane, S. ;
Fagan, A. J. ;
Browne, J. E. .
ULTRASOUND, 2012, 20 (01) :16-23
[7]   Three-Dimensional Shear Wave Elastography Using a 2D Row Column Addressing (RCA) Array [J].
Dong, Zhijie ;
Kim, Jihun ;
Huang, Chengwu ;
Lowerison, Matthew R. ;
Lok, U-Wai ;
Chen, Shigao ;
Song, Pengfei .
BME FRONTIERS, 2022, 2022
[8]   Invasive Breast Cancer: Relationship between Shear-wave Elastographic Findings and Histologic Prognostic Factors [J].
Evans, Andrew ;
Whelehan, Patsy ;
Thomson, Kim ;
McLean, Denis ;
Brauer, Katrin ;
Purdie, Colin ;
Baker, Lee ;
Jordan, Lee ;
Rauchhaus, Petra ;
Thompson, Alastair .
RADIOLOGY, 2012, 263 (03) :673-677
[9]   Shear Wave Elastography for Evaluation of Liver Fibrosis [J].
Ferraioli, Giovanna ;
Parekh, Parth ;
Levitov, Alexander B. ;
Filice, Carlo .
JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (02) :197-203
[10]   Accuracy of Real-Time Shear Wave Elastography for Assessing Liver Fibrosis in Chronic Hepatitis C: A Pilot Study [J].
Ferraioli, Giovanna ;
Tinelli, Carmine ;
Dal Bello, Barbara ;
Zicchetti, Mabel ;
Filice, Gaetano ;
Filice, Carlo .
HEPATOLOGY, 2012, 56 (06) :2125-2133