PERFORMANCE OF A GUIDED WAVE PIPE MONITORING SYSTEM OVER EXTENDED PERIODS OF FIELD OPERATION

被引:4
作者
Mariani, Stefano [1 ]
Heinlein, Sebastian [1 ]
Vogt, Thomas [1 ]
Cawley, Peter [1 ,2 ]
机构
[1] Guided Ultrason Ltd, London TW8 8HQ, England
[2] Imperial Coll, London SW7 2AZ, England
关键词
guided wave; monitoring; permanently installed; pipes; corrosion; stability; FUNDAMENTAL TORSIONAL MODE; REFLECTION;
D O I
10.32548/2023.me-04335
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The performance of a permanently installed guided wave pipe monitoring system over extended periods has been investigated. Other than at a clamped support, the signals obtained in the three installations reported here have been stable to better than 1% (-40 dB) over periods of 12-24 months, even in hostile oil and gas facility environments. The use of baseline subtraction means that the sensitivity to defects is substantially better than that obtained in one-off inspection; in the two site examples reported here, improvements of 7 and 12 dB relative to one-off interpretation of the A-scan signal were obtained, and changes can be flagged automatically. The improvement in sensitivity is even larger at features such as welds and bends, which give significant reflections even in the absence of damage. The permanently installed system combines long-range guided wave monitoring for localized corrosion patches with eight precise thickness measurements around the pipe circumference, making it possible to monitor the general wall loss rate, as well as detect any more severe, localized corrosion. Permanently installed guided wave monitoring systems are therefore found to be a commercially attractive tool for the assessment of current and future piping integrity. KEYWORDS: guided wave, monitoring, permanently installed,
引用
收藏
页码:36 / 46
页数:11
相关论文
共 26 条
[1]  
Alleyne D. N., 1996, Journal of Nondestructive Evaluation, V15, P11, DOI 10.1007/BF00733822
[2]  
Alleyne DN, 2001, INSIGHT, V43, P93
[3]  
ASTM, 2011, Standard Practice for Guided Wave Testing of Above Ground Steel Pipework Using Piezoelectric Effect Transduction, DOI [10.1520/E2775-11, DOI 10.1520/E2775-11]
[4]  
BSI, 2011, BS 9690-2: Non -Destructive Testing. Guided Wave Testing. Basic Requirements for Guided Wave Testing of Pipes, Pipelines and Structural Tubulars (British Standard)
[5]   The effect of complex defect profiles on the reflection of the fundamental torsional mode in pipes [J].
Carandente, Rosalba ;
Cawley, Peter .
NDT & E INTERNATIONAL, 2012, 46 :41-47
[6]   Structural health monitoring: Closing the gap between research and industrial deployment [J].
Cawley, Peter .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2018, 17 (05) :1225-1244
[7]   Guided wave health monitoring of complex structures by sparse array systems: Influence of temperature changes on performance [J].
Clarke, T. ;
Simonetti, F. ;
Cawley, P. .
JOURNAL OF SOUND AND VIBRATION, 2010, 329 (12) :2306-2322
[8]   The reflection of the fundamental torsional mode from cracks and notches in pipes [J].
Demma, A ;
Cawley, P ;
Lowe, M ;
Roosenbrand, AG .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 114 (02) :611-625
[9]   The reflection of guided waves from simple supports in pipes [J].
Galvagni, Andrea ;
Cawley, Peter .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (04) :1869-1880
[10]   Environmental and operational conditions effects on Lamb wave based structural health monitoring systems: A review [J].
Gorgin, Rahim ;
Luo, Ying ;
Wu, Zhanjun .
ULTRASONICS, 2020, 105