Energy, economic, and environmental evaluation of a GAX-based cross-type absorption-resorption heat pump

被引:8
|
作者
Su, Wei [1 ]
Han, Yuhao [1 ]
Jin, Xu [1 ]
Liu, Zhongyan [1 ]
Zhang, Xiaosong [2 ]
机构
[1] Northeast Elect Power Univ, Sch Energy & Power Engn, Jilin 132012, Peoples R China
[2] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
关键词
Generator -absorber heat exchange (GAX) based; Ammonia; -water; Cross -type absorption -resorption; Energy; exergy; economy and environment (4E); CYCLE; RECOVERY; DRIVEN;
D O I
10.1016/j.enconman.2023.117952
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermally driven absorption heat pump is regarded as one of the most promising methods to efficiently utilize low-grade heat, reduce energy consumption and greenhouse gas emissions. However, there are still limitations when using it at low ambient temperature in cold regions, and its application is limited by their low system performance. In this study, we proposed a novel Generator-absorber heat exchange (GAX) based NH3/H2O crosstype absorption-resorption heat pump driven by waste flue gas, which amalgamates the absorption-resorption and GAX cycles, yielding a dual advantage of diminished heat source temperature and operating pressure requirements. Additionally, it substantively enhances the system's performance by capitalizing on the cross-type solution cycle integration. A mathematical model has been developed and the results have been compared and validated with those reported in the literature. The proposed system is comprehensively studied from the view of energy, exergy, economic and environmental (4E) analysis to determine its advantages and disadvantages. The results reveal that the proposed system achieves a maximum COP of 2.742 under specific operating conditions, which is 82.8% higher than the conventional absorption heat pump (AHP), and 30.57% higher than the conventional GAX-AHP. Besides, the addition of a compressor can significantly enhance the performance of the system at lower driving heat source temperatures. At a PH/PL pair of 1.7/0.47 MPa, the static payback period is 4.113 years, with the heating capacity of 88.51 kW and the supply water temperature of 54.6 degrees C, showcasing favorable system performance. Furthermore, the total atmospheric pollutant emissions could be reduced by 30,998 kg/year compared to the conventional heating method.
引用
收藏
页数:24
相关论文
共 24 条
  • [1] Thermodynamic analysis of an ammonia-water solution cross-type absorption-resorption heat pump system
    Feng, Lijie
    Jin, Zhenghao
    Zhou, Runfa
    Xu, Mengkai
    Qin, Luwen
    Li, Shuhong
    APPLIED THERMAL ENGINEERING, 2021, 198
  • [2] Working domains of a novel solar-assisted GAX-based two-stage absorption-resorption heat pump with multiple internal heat recovery for space heating
    Jia, Teng
    Chu, Peng
    Dou, Pengbo
    Dai, Yanjun
    ENERGY CONVERSION AND MANAGEMENT, 2020, 220
  • [3] Energy and exergy analysis of a solution cross-type absorption-resorption heat pump using NH3/H2O as working fluid
    Jin Z.
    Feng L.
    Li S.
    Huagong Xuebao/CIESC Journal, 2023, 74 : 53 - 63
  • [4] Performance research of a solution cross-type absorption-resorption heat transformer using NH 3 /H 2 O work fluid
    Shen, Zhili
    Li, Shuhong
    Feng, Lijie
    Jin, Zhenghao
    Du, Kai
    Li, Yanjun
    Sheng, Wei
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [5] Feasibility and performance analysis of a hybrid GAX-based absorption-compression heat pump system for space heating in extremely cold climate conditions
    Jia, Teng
    Dou, Pengbo
    Chen, Erjian
    Dai, Yanjun
    ENERGY, 2022, 242
  • [6] Theoretical and experimental investigation on a GAX-Based NH3-H2O absorption heat pump driven by parabolic trough solar collector
    Dai, Enqian
    Jia, Teng
    Dai, Yanjun
    SOLAR ENERGY, 2020, 197 : 498 - 510
  • [7] Experimental investigation on a GAX based absorption heat pump driven by hybrid liquefied petroleum gas and solar energy
    Dai, Enqian
    Lin, Meng
    Xia, Jiahao
    Dai, Yanjun
    SOLAR ENERGY, 2018, 169 : 167 - 178
  • [8] Performance Investigation on a Single-stage Balanced-type NH3-H2O Absorption-resorption Heat Pump Cycle
    Jia, Teng
    Dou, Peng-Bo
    Dai, Yan-Jun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (04): : 797 - 802
  • [9] Thermodynamic analysis and optimization of a balanced-type single-stage NH3-H2O absorption-resorption heat pump cycle for residential heating application
    Jia, Teng
    Dai, Enqian
    Dai, Yanjun
    ENERGY, 2019, 171 : 120 - 134
  • [10] Absorption and compression heat pump systems for space heating and DHW in European buildings: Energy, environmental and economic analysis
    Scoccia, Rossano
    Toppi, Tommaso
    Aprile, Marcello
    Motta, Mario
    JOURNAL OF BUILDING ENGINEERING, 2018, 16 : 94 - 105