Reproducibility of peak moment for isometric and isokinetic knee extension exercise

被引:1
|
作者
Zoeger, Manfred [1 ,2 ,3 ]
Nimmerichter, Alfred [1 ,2 ]
Baca, Arnold [2 ]
Wirth, Klaus [1 ]
机构
[1] Univ Appl Sci Wiener Neustadt, Training & Sports Sci, Johannes Gutenberg Str 3, A-2700 Wiener Neustadt, Austria
[2] Univ Vienna, Ctr Sport Sci & Univ Sports, Schmelz 6, A-1150 Vienna, Austria
[3] Univ Vienna, Doctoral Sch Pharmaceut Nutr & Sport Sci, Josef Holaubek Pl 2, A-1090 Vienna, Austria
关键词
Reproducibility; Isomed; 2000; Dynamometer; Isometric; Isokinetic; TEST-RETEST RELIABILITY; STRENGTH; FLEXION; DYNAMOMETRY; BASKETBALL; IMBALANCE; PROTOCOL; BIODEX; INJURY;
D O I
10.1186/s13102-023-00788-z
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
BackgroundAccurate measurements of muscular performance are important for diagnostics, for example during rehabilitation after traumatic injuries but also in competitive sports. For these purposes, dynamometric devices are widely used and considered the gold standard for muscle strength testing. However, few previous studies have tested the reproducibility of peak moment (PM) at velocities close to the maximum device capability, and in general, reproducibility results cannot be transferred to other devices or test protocols. The purpose of this study was to evaluate the reproducibility of PM for different isometric and isokinetic knee extension exercises using the IsoMed 2000.MethodsThirty subjects volunteered in three repeated test sessions, including isometric knee extension (100 degrees and 140 degrees knee angle) and isokinetic knee extension (30 degrees/s and 400 degrees/s). Statistical analysis for comparison of sessions two and three included paired sample t-test, calculation of intraclass correlation coefficient (ICC) and standard error of measurement (SEM). Additionally, Bland Altman statistics and corresponding plots were created.ResultsA significant difference between sessions in PM was found for isometric knee extension in one leg (140 degrees left). Reproducibility was high for all conditions with ICC ranging from 0.964 to 0.988 and SEM in the range of 7.6 to 10.5 Nm. Bland Altman statistics revealed a bias between - 7.3 and 0.7 Nm.ConclusionsReproducibility of PM using the IsoMed 2000 was good after an initial familiarization trial with high values of relative reproducibility. Absolute reproducibility can be interpreted as appropriate for most common practical applications.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] EFFECTS OF ISOKINETIC TRAINING OF THE KNEE EXTENSORS ON ISOMETRIC STRENGTH AND PEAK POWER OUTPUT DURING CYCLING
    MANNION, AF
    JAKEMAN, PM
    WILLAN, PLT
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 65 (04): : 370 - 375
  • [22] Comparison of the effectiveness of isokinetic exercise vs isometric exercise performed at different angles in patients with knee osteoarthritis
    Kilinc, Serdar
    Kabayel, Derya D.
    Ozdemir, Ferda
    ISOKINETICS AND EXERCISE SCIENCE, 2020, 28 (01) : 35 - 47
  • [23] ISOMETRIC AND ISOKINETIC KNEE EXTENSION AND FLEXION TORQUE IN MEN AND WOMEN AGED 20-70
    BORGES, O
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1989, 21 (01): : 45 - 53
  • [24] Feedback Effect on Peak Torque During a Knee Extension Isokinetic Protocol in Female Athletes
    Warren, Barbara L.
    Ely, Claire
    Wright, Kevin
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 376 - 376
  • [25] Inertial effects on moment development during isokinetic concentric knee extension testing - Response
    Iossifidou, A
    Baltzopoulos, V
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2000, 30 (06): : 326 - 327
  • [26] Knee Wraps Increase Peak Torque During Isokinetic Leg Extension in Collegiate Powerlifters
    Fincher, Glen E.
    Rohr, Joshua A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S378 - S378
  • [27] SUPINE VS SEATED ISOKINETIC KNEE FLEXION/EXTENSION JOINT ANGLE AT PEAK TORQUE
    Provenzano, D. L.
    Findley, B. W.
    Brown, L. E.
    Asper, D. E.
    Drake, C. K.
    Whitehurst, M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S28 - S28
  • [28] Feedback Effect on Peak Torque During a Knee Extension Isokinetic Protocol in Female Athletes
    Warren, Barbara L.
    Ely, Claire
    Wright, Kevin
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 376 - 376
  • [29] Absolute reliability of conventional and functional ratios and peak isokinetic torque of knee flexion and extension
    Ayala, Francisco
    Sainz de Baranda, Pilar
    De Ste Croix, Mark
    Sarobe, Lorea
    APUNTS-MEDICINA DE L ESPORT, 2012, 47 (174) : 55 - 64
  • [30] Stationarity analysis of surface electromyographic signals on the phases of the isokinetic knee extension exercise
    Análise da estacionariedade do sinal de eletromiografia de superfície nas fases do exercício isocinético de extensão do joelho
    Schwartz, F. P. (fpschwartz@unb.br), 1600, Sociedade Brasileira de Engenharia Biomedica, Caixa Postal 68510, Rio de Janeiro, RJ, 21941-972, Brazil (28):